• Title/Summary/Keyword: Mobile radiography

Search Result 15, Processing Time 0.034 seconds

Augmented Reality Technology-based Dental Radiography Simulator for Preclinical Training and Education on Dental Anatomy

  • Gu, Ja-Young;Lee, Jae-Gi
    • Journal of information and communication convergence engineering
    • /
    • v.17 no.4
    • /
    • pp.274-278
    • /
    • 2019
  • It is important that students are provided opportunities to practice their skills in acquiring radiographic images. However, these opportunities are currently limited because of the risk of radiation exposure. To overcome this limitation, a new augmented reality-based radiography simulator was developed that enables students to practice radiographic techniques as part of self-directed learning without time and space constraints. Subsequently, cross-sectional images of a manikin phantom head obtained via computed tomography were reconstructed into a three-dimensional object. An image marker that could be recognized by a mobile device and could allow users to practice dental radiography techniques was devised. The three-dimensional object was augmented to the mobile device; consequently, among 106 stored dental radiographs on the device, a radiograph corresponding to specific imaging conditions was opened when users performed radiographic procedures. This technology could improve dental students' understanding of dental anatomy and contribute to improving their competency in acquiring dental radiographs.

A Study on the Scattered Dose in Portable Chest Radiography (portable 흉부촬영시 공간산란선량에 관한 연구)

  • Ahn, Bong-Seon;Lee, Hwan-Hyung
    • Journal of radiological science and technology
    • /
    • v.23 no.2
    • /
    • pp.63-67
    • /
    • 2000
  • The purpose of this study is to survey the present status of portable radiography and the result of free space scattered dose rate when taking a radiography at the general hospital or the university hospital in Taejon city. The results were as follows; 1. The number of cases using portable radiography for three years increased to averages 16.2%, 7.7% per year from January 1st in 1996 to December 31st in 1998. 2. The average of distance of adjacent patients was 219.1 cm at the ward. 3. For portable chest radiography, the free space scattered dose rate was 10.5 mSv/hr at 50 cm distance, 1.8 mSv/hr at 100 cm distance, and 0.2 mSv/hr at 200 cm distance. Therefore, in case of portable chest radiography at the ward, the average of distance of adjacent patients is 219.1 cm, so it does not have influence on the adjacent patients. But during the portable radiography, a guardian who is close to the patient, doctor, nurse and radiologic technologists has to set up the shield to prevent from the unnecessary radiation or the distance should be as great as possible from the mobile X-ray equipment.

  • PDF

Infection Control of Computed Radiography Portable in Radiology (영상의학과 이동촬영장비의 감염 관리)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.117-122
    • /
    • 2017
  • The purpose of this study is to prevent infection in the hospital by computed radiography portable and to provide basic data on infection-related education by investigating bacterial contamination level of computed radiography portable equipment using IP cassette. The results suggest that IP cassette No. 1 is infected with CNS and VRE, no. 2 with CNS, No. 3 with CNS and Pseudomonas aeruginosa, No. 4 with CNS, No. 5 with CNS and Bacillus sp., and No. 6 with enterococcus faecium. Enterococcus faecium and bacillus sp. were detected from the IP reader and Acinetobacter baumannii was detected on the mobile handle; Bacillus sp. on the control buttons, CNS and Bacillus sp. from the irradiation control handle, Acinetobacter baumannii on the x-ray generation switch, and CNS on the barcode scanner. In addition, Bacillus sp. Acinetobacter baumannii was found on the IP cassette mobile table and CNS and bacillus sp. were found on the lead apron. Acinetobacter baumannii and CNS were detected from the medical gloves worn by a radiological technologist during radiography. This suggests that IP cassette should be sterilized after use as it can hand over bacteria to IP reader and IP mobile table. Medical gloves that are in direct contact with patients should also be replaced after using them once and other supplies such as x-ray generation switch and lead apron should thoroughly be sterilized to prevent infection due to radiography as they are in a lot of contact with patients.

Measurement of the Scattered Spatial Dose Distribution for the Mobile X-ray Radiography (이동형 X선촬영에서 공간산란선량 분포 측정)

  • Kwon, Deok-Mun;Park, Myeong-Hwan;Nam, Hyo-Duk
    • Journal of radiological science and technology
    • /
    • v.24 no.1
    • /
    • pp.23-26
    • /
    • 2001
  • The spatial distribution of the scattered dose for mobile X-ray radiography is measured. The scattered X-ray exposures at the radius of 50, 100 and 150 cm from the irradiation center are 880, 180 and $50\;{\mu}R$, respectively. This scattered X-rays can be reduced to 60% by inserting the portable shield made by 0.4 mm copper sheet sandwiched in two plywoods.

  • PDF

A Study on Distortion and Dose of Images in Mobile Radiography (이동형 방사선검사에서 영상의 왜곡과 선량에 관한 연구)

  • Song, Hyeon-Seok;Lim, Cheong-Hwan;Jung, Hong-Ryang;Kim, Jong-Seong;Kim, Yeong-Ran;Jeong, Sung-Hun
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.305-312
    • /
    • 2022
  • The proportion and testing of portable radiation tests, which are limited at the request of the doctor, are gradually increasing only for patients in emergency situations and difficulties in moving. However, as there are many limiting factors compared to fixed devices, this study intends to measure and analyze the distortion of images according to the angle of the detector and the change in dose according to the position of the subject. For distortion experiments using a mobile radiation generator used in Hospital A, the SID was tilted by 110 cm, 14"×17" wireless FPD detector to 0°, -5°, -10°, -15°, -20°, and -35° to measure the change in area. The dose according to the location of the detector was analyzed on average by measuring the central dose at 110 cm of the SID and measuring the dose of 9 locations three times each. The analysis result of distortion by location according to the angle of the detector showed a statistically significant difference (f=58.74, p<0.000). Therefore, it can be seen that the angle of the detector and the tube is closely related to the distortion of the image. The difference in dose by location of the detector increased with respect to the center - pole, and decreased with the + pole. Tests using mobile radiation generators will require careful efforts by clinicians to position patients in the center of the detector for accurate diagnosis, and efforts will be made to level the angle between the mobile radiation generators and the detector.

Convergence and integration study related to development of digital contents for radiography training using dental radiograph and augmented reality (치과방사선사진과 증강현실을 활용한 방사선촬영법 숙련용 디지털 콘텐츠 개발에 대한 융복합 연구)

  • Gu, Ja-Young;Lee, Jae-Gi
    • Journal of Digital Convergence
    • /
    • v.16 no.12
    • /
    • pp.441-447
    • /
    • 2018
  • This study aims to develop digital techniques that enable repeated practice of dental radiography using augmented reality technology. A three-dimensional object was fabricated by superimposing a photograph of an adult model and a computed tomography image of a manikin phantom. The system was structured using 106 radiographs such that one of these saved radiographs is opened when the user attempts to take a radiograph on a mobile device. This system enabled users to repeatedly practice at the pre-clinical stage without exposure to radiation. We attempt to contribute to enhancing dental hygienists' competency in dental radiography using these techniques. However, a system that enables the user to actually take a radiograph based on face recognition would be more useful in terms of practice, so additional studies are needed on the topic.

A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index (Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구)

  • Kim, Jae-In;Lee, Yang-Sub;Jang, Dong-Soo;Jung, Min-Cheol;Bae, Seung-Ho;Lee, Kwan-Sub;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF

Measurement of Skin Dose Distribution for the Mobile X-ray Unit Collimator Shielding Device (이동형 X선 장치 차폐도구 제작을 통한 표면선량 분포 측정)

  • Hong, Sun-Suk;Kim, Deuk-Yong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.5-8
    • /
    • 2010
  • Opened a court in February 10, 2006, a rule of safety management of the diagnosis radiation system was promulgated for safety of the radiation worker, patients and patients' family members. The purpose of this rule is to minimize the risk of being exposed to radiation during the process of handling X-ray. For this reason, we manufactured shielding device of mobile X-ray unit collimator for diminution of skin dose. Shielding device is made to a thickness of Pb 0.375mm. For portable chest radiography, we measured skin dose 50cm from center ray to 200cm at intervals of 20cm by Unfors Xi detector. As a result, a rule of safety management of the diagnosis radiation system has been strengthened. But there are exceptions, such as ER, OR, ICU to this rule. So shielding device could contribute to protect unnecessary radiation exposure and improve nation's health.

  • PDF

A 16kw Rotating Anode type Monoblock X-ray Generator (16kW 회전 Aonde형 모노블럭 X-선 발생장치)

  • Oh, Jun-Yong;Kim, Yuen-Chung;Kim, Hack-Seong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.97-103
    • /
    • 2006
  • This paper designs mono block type with rotating high power radiography x-ray generator and studies 16kW X-ray generator possible to adapt hospital mobile radiography and industrial X-ray equipment and design. This equipment uses rotating anode type x-ray tube at high voltage generator to generate x-ray and adds rotor operating circuit to operate rotor of x-ray tube. The size of high voltage transformer and high voltage generator is minimized by high voltage high frequency inverter has 100kHz switching frequency. Also this paper shows result of x-ray tube voltage and tube current correspond to variable load.

Construction and Performance Evaluation of Digital Radiographic System (이동형 디지털 X선 촬영장치의 구축 및 성능평가)

  • Cho, Hyo-Min;Nam, So-Ra;Lee, Chang-Lae;Jung, Ji-Young;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.144-148
    • /
    • 2007
  • Current digital radiography systems are rapidly glowing in clinical applications. The purpose of this study was to evaluate the characteristics of a mobile digital radiographic system. The performance of the mobile DR system was evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Measurements were made on a LISTEM Mobix-1000 generator and a Teleoptic PRA Alpha-R4000 detector. Imaging characteristics were measured for these two systems using the IEC-61267 defined RQA5 (kVp: 74, additional filtration: 21 mmAl) radiographic condition. The MTF at 10% was measured as 2.4 cycles/mm and the DQE(0) values for radiation exposure 0.19, 0.5, and 1.3 mR were measured as 54%, 55%, and 76%, respectively. The NPS curves gradually decreased at high spatial frequencies. This high DQE at low frequencies, may be useful for low frequency information. The results suggested that mobile DR system could be integrated with emergency ambulance system in teleradiologic imaging applications.

  • PDF