• 제목/요약/키워드: Minimum Performance

검색결과 3,170건 처리시간 0.031초

Improvement of Minimum MSE Performance in LMS-type Adaptive Equalizers Combined with Genetic Algorithm

  • Kim, Nam-Yong
    • Journal of electromagnetic engineering and science
    • /
    • 제4권1호
    • /
    • pp.1-7
    • /
    • 2004
  • In this paper the Individual tap - Least Mean Square(IT-LMS) algorithm is applied to the adaptive multipath channel equalization using hybrid-type Genetic Algorithm(GA) for achieving lower minimum Mean Squared Error(MSE). Owing to the global search performance of GA, LMS-type equalizers combined with it have shown preferable performance in both global and local search but those still have unsatisfying minimum MSE performance. In order to lower the minimum MSE we investigated excess MSE of IT-LMS algorithm and applied it to the hybrid GA equalizer. The high convergence rate and lower minimum MSE of the proposed system give us reason to expect that it will perform well in practical multi-path channel equalization systems.

고성능콘크리트의 배합설계 (Mix Design of High Performance Concrete)

  • 정용욱;이승한;윤용호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.73-76
    • /
    • 2005
  • This study aims to suggest a simple and convenient design for a mix proportion method for high performance concrete by determining the optimum fine aggregate ratio and minimum binder content based on the maximum density theory. The mix design method introduced in this study adopted the optimum fine aggregate ratio with a minimum void and binder content higher than the minimum binder content level. The research results reveal that the method helps to reduce trial and error in the mixing process and is a convenient way of producing high performance concrete with self filler ability. In an experiment based on the mix proportion method, when aggregate with the fine aggregation ratio of 41$\%$ was used, the minimum binder content of high performance concrete was 470kg/$m^{3}$ and maximum aggregate capacity was $0.657m^{3}/m^{3}$. In addition, in mixing high performance concrete, the optimal slump flow to meet filler ability was 65$\pm$5cm, V load flow speed ranged from 0.5 to 1.5.

  • PDF

Gate-to-Drain Capacitance Dependent Model for Noise Performance Evaluation of InAlAs/InGaAs Double-gate HEMT

  • Bhattacharya, Monika;Jogi, Jyotika;Gupta, R.S.;Gupta, Mridula
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권4호
    • /
    • pp.331-341
    • /
    • 2013
  • In the present work, the effect of the gate-to-drain capacitance ($C_{gd}$) on the noise performance of a symmetric tied-gate $In_{0.52}Al_{0.48}As/In_{0.53}Ga_{0.47}As$ double-gate HEMT is studied using an accurate charge control based approach. An analytical expression for the gate-to-drain capacitance is obtained. In terms of the intrinsic noise sources and the admittance parameters ($Y_{11}$ and $Y_{21}$ which are obtained incorporating the effect of $C_{gd}$), the various noise performance parameters including the Minimum noise figure and the Minimum Noise Temperature are evaluated. The inclusion of gate-to-drain capacitance is observed to cause significant reduction in the Minimum Noise figure and Minimum Noise Temperature especially at low values of drain voltage, thereby, predicting better noise performance for the device.

일반화최소분산 적응제어를 이용한 유압 서보계의 특성개선에 관한 연구 (Characteristics Improvement of Hydraulic Servosystem by Using Generalized Minimum Variance Adaptive Control)

  • 박용호;김기홍;이진걸
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권3호
    • /
    • pp.388-394
    • /
    • 2003
  • Hydraulic system is difficult to obtain a suitable performance due to the nonlinearity load pressure change and system parameter variation. The requirement of control a1gorithm has been complex in order to satisfy the performance. The adaptive control is a control method which is suggested to achieve the control object under the plant characteristics change. In spite of the case that plant characteristics and the degree of variation are difficult to grasp. the adaptive control could keep the characteristics of closed-loop system generally. In this study. a method of combined generalized minimum variance adaptive control (GMVAC) and output error feedback is proposed, in order to solve the problem of non-minimum phase of plant and the vibration and overshoot in initial response. The control performance according to the variation of characteristics of plant is evaluated by changing the supply pressure. The experimental results show the effectiveness of the proposed scheme.

Plant Minimum Stable Load (Pmin) Test for Ilijan CCPP

  • Kim, Si Moon;Yun, Wan No;Jang, Cheol Ho;Park, Se Ik
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권1호
    • /
    • pp.83-88
    • /
    • 2016
  • This paper describes the test results of plant minimum stable load (Pmin) for Ilijan Power Plant. The test was conducted on May 13 through 14, 2015 to investigate the plant operating and equipment condition in accordance with "Ilijan Plant Performance Test Procedure on Plant Minimum Stable Load" [1]. This paper also contains the assessment of the impact of Pmin to plant operating parameters and possible technical operating issues when operating at lower loads and to recommend the safe minimum load operation of Ilijan per block. In addition, this paper describes the performance calculation results of efficiency and heat rate depending on the load level.

W-CDMA 단말기 수신 시스템에서 요구하는 최소성능 분석 및 설계에 관한 연구 (A Study on the Analysis of Minimum Performance and Design for Receiver System in W-CDMA Handset)

  • 곽준호;윤석출;김학선
    • 한국통신학회논문지
    • /
    • 제29권9A호
    • /
    • pp.1005-1012
    • /
    • 2004
  • 본 논문에서는 W-CDMA 단말기 표준안에서 요구하는 최소 성능을 분석하고 현재 상용화되어 있는 부품들을 사용하여 W-CDMA 단말기 수신부를 설계 및 제작하였다 표준안의 테스트 조건들로부터 수신 시스템의 최대 잡음지수와 IIP3 을 도출하였으며, 인접채널에 대한 선택도 및 프콘트 -엔드 단의 최소 성능을 경쟁하였다 제작에 앞 서 ADS 를 이용하여 성능검증을 하였으며 , 모두 분석된 최소성능을 만족하였다. 끝으로 W-CDMA 단말기 수신부 를 헤테로다인 구조로 R 단에서 IF 단까지 제작하였으며, 측정을 하였다 따라서 본 논문이 W-CDMA 단말기를 제작함에 있어 이론적인 설계 기준이 될 것으로 여겨진다.

접합부 회전성능에 따른 중간 철골 모멘트 골조의 내진 성능 평가 - I 성능평가 (Seismic Performance Evaluation According to Rotation Capacity of Connections for Intermediate Steel Moment Frames - I. Performance Evaluation)

  • 문기훈;한상환;하성진
    • 한국지진공학회논문집
    • /
    • 제18권2호
    • /
    • pp.95-103
    • /
    • 2014
  • The current AISC341-10 standard specifiesa value of 0.02 radian for the minimum rotation capacity of connections for the intermediate steel moment frame system. However, despite of the advances realized in the domains of performance evaluation method and analysis method, research onthe minimum rotation capacity of the intermediate steel moment frame systemsatisfying the seismic performance has not been conducted in detail. In this study, the intermediate moment frame systemisdesigned with respect to current standards and the seismic performance in accordance with the rotational capacity of connections is evaluated using the seismic performance evaluation method presented in FEMA-P695. The minimum rotation capacity of intermediate steel moment frames required to satisfy seismic performance as well as the major design values affecting the seismic performance of moment frame areestimated. To that goal, the design parameters are selected and various target frames are designed. The analysis models of the main nonlinear elements are also developed for evaluating seismic performance. The resultsshow that the 20-story structure doesnot meet the seismic performance even if it satisfies the rotation capacity of 0.02 radian.

침투성장거리를 이용한 로봇팔의 장애물회피 최적운동 (Obstacle-Free Optimal Motions of a Manipulator Arm Using Penetration Growth Distance)

  • 박종근
    • 한국정밀공학회지
    • /
    • 제18권10호
    • /
    • pp.116-126
    • /
    • 2001
  • This paper suggests a numerical method to find optimal geometric path and minimum-time motion for a spatial 6-link manipulator arm (PUMA 560 type). To find a minimum-time motion, the optimal geometric paths minimizing 2 different dynamic performance indices are searched first, and the minimum-time motions are searched on these optimal paths. In the algorithm to find optimal geometric paths, the objective functions (performance indices) are selected to minimize joint velocities, actuator forces or the combinations of them as well as to avoid one static obstacle. In the minimum-time algorithm the traveling time is expressed by the power series including 21 terms. The coefficients of the series are obtained using nonlinear programming to minimize the total traveling time subject to the constraints of velocity-dependent actuator forces.

  • PDF

Robust Minimum-Time Control with Coarse/Fine Dual-Stage Mechanism

  • Kwon, Sang-Joo;Cheong, Joo-No
    • Journal of Mechanical Science and Technology
    • /
    • 제20권11호
    • /
    • pp.1834-1847
    • /
    • 2006
  • A robust minimum-time control (RMTC) strategy is addressed and it is extended to the dual-stage servo design. Rather than conventional switching type sub-optimal controls, it is a reference following control approach where the predetermined minimum-time trajectory (MTT) is tracked by the perturbation compensator based feedback controller. First, the minimum-time trajectory for a mass-damper system is derived. Then, the perturbation compensator to achieve robust tracking performance in spite of model uncertainty and external disturbance is suggested. The RMTC is also applied to the dual-stage positioner which consists of coarse actuator and fine one. To best utilize the actuation redundancy of the dual-stage mechanism, a null-motion controller to actively regulate the relative motion between the two stages is formulated. The performance of RMTC is validated through simulation and experiment.

원전시설의 내진성능평가를 위한 입력지반운동의 최소개수 (Minimum Number of Input Ground-motions to Assess Seismic Performance of Nuclear Facilities)

  • 홍기증;최지혜;김현욱;주광호
    • 한국지진공학회논문집
    • /
    • 제20권5호
    • /
    • pp.341-349
    • /
    • 2016
  • Currently, researches are being actively conducted in assessing seismic performance of nuclear facilities in USA and Europe. In particular, applying this technique of assessing seismic performance to design of isolation systems in nuclear power plants is being performed and then ASCE 4 Draft (2013) is being revised accordingly in the United States. In order to satisfy the probabilistic performance objectives described by seismic responses with certain confidence levels (ASCE 43, 2005), the probability distributions of these responses have to be defined. What is the minimum number of input ground-motions to obtain the probability distribution precise enough to represent the unknown actual distribution? Theoretical basis, for how to determine the minimum number of input ground-motions for given a logarithmic standard deviation to approximate the unknown actual median of the log-normal distribution within a range of error at a certain level of confidence, is introduced by Huang et al. (2008). However, the relationship between the level of confidence and the range of error is not stated in the previous study. In this paper, based on careful reviews on the previous work, the relationship between the level of confidence and the range of error is logically and explicitly stated. Furthermore, this relationship is also applied to derive the minimum number of input ground-motions in order to approximate the unknown actual logarithmic standard deviation. Several recommendations are made for determining the minimum number of input ground-motions in probabilistic assessment on seismic performance of facilities in nuclear power plants.