• 제목/요약/키워드: Microvalves

검색결과 10건 처리시간 0.028초

녹내장 치료용 수동형 밸브의 제작 (A Study on Passive Microvalve for Glaucoma)

  • 심태석;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.64-66
    • /
    • 2002
  • This paper reports the design, modeling, fabrication and measurement of passive microvalves applicable to glaucoma implants. The proposed microvalves consisted of microchannels and chambers. The microchannels had a fixed fluidic resistance and generated a pressure difference. The chamber was located in the middle of the microchannels and acted as a buffer preventing an abrupt pressure change from an external variation of the fluid flow. To find optimum design parameters, six kinds of the microvalves were fabricated and experimented.

  • PDF

A Study on the Passive Microvalve Applicable to Drainage Device for Glaucoma

  • Sim, Tae-Seok;Kim, Yong-Kweon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제2권4호
    • /
    • pp.253-258
    • /
    • 2002
  • This paper reports the design, modeling, fabrication and measurement of passive microvalves, which are applicable to glaucoma implants. The proposed microvalves were designed using fluidic theory. The microvalves consisted of microchannels and chambers. The microchannels had a constant fluidic resistance generating a pressure difference. Six kinds of microvalves were designed using fluidic equations for laminar flow and fabricated to examine the influences of chamber size, channel length and the shape of channel cross section. The pressure difference between the designed microvalve and the fabricated microvalve was measured to be less than 4%.

열공압 방식의 Polydimethylsiloxane 마이크로 밸브의 제작 및 특성 (Fabrication and Characteristics of Thermopneumatic-Actuated Polydimethylsiloxane Microvalve)

  • 김진호;조주현;한경희;김영호;김한수;김용상
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권4호
    • /
    • pp.231-236
    • /
    • 2004
  • A normally open thermopneumaticc-actuated microvalve has been fabricated and their properties are investigated. The advantages of the proposed microvalve are of the low cost fabrication process and the transparent optical property using polydimethylsiloxane (PDMS) and indium tin oxide (ITO) glass. The fabricated microvalves with in-channel configuration are easily integrated with other microfluidic devices on the same substrate. The fabrication process of thermopneumatic-actuated microvalvesusing PDMS is very simple and its performance is very suitable for a disposable lab-on-a-chip. The PDMS membrane deflection increases and the flow rates of the microchannel with microvalvels decrease as the applied power to the ITO heater increases. The powers at flow-off are dependent on the membrane thickness and the applied inlet pressure but are independent of the channel width of microvalves. The flow rate is well controlled by the switching function of ITO heater and the closing/opening times are around 20 sec and 25 sec, respectively.

열공압 방식으로 구동되는 매세 유체 제어 시스템의 제작 및 특성 (Fabrications and Characteristics of Microfluidic Systems Actuated by Thermopneumatic Method)

  • 유종철;강치중;김용상
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권2호
    • /
    • pp.88-92
    • /
    • 2006
  • We present a microfluidic system with microvalves and a micropump that are easily integrated on the same substrate using the same fabrication process. The fabricated microfluidic system is suitable for use as a disposable device and its characteristics are optimized for use as a micro chemical analysis system (micro-TAS) and lab-on-a-chip. The system is realized by means of a polydimethylsiloxane (PDMS)-glass chip and an indium tin oxide (ITO) heater. We demonstrate the integration of the micropump and microvalves using a new thermopneumatic-actuated PDMS-based microfluidic system. A maximum pumping rate of about 730 nl/min is observed at. a duty ratio of 1 $\%$ and a frequency of 2 Hz with a fixed power of 500 mW. The measured power at flow cut-off is 500 mW for the microvalve whose channel width, depth and membrane thickness were 400 $\mu$m, 110 $\mu$m, and 320 $\mu$m, respectively.

미소유체시스템을 위한 실용적인 패키징 기술 (Practical Packaging Technology for Microfluidic Systems)

  • 이환용;한송이;한기호
    • 대한기계학회논문집B
    • /
    • 제34권3호
    • /
    • pp.251-258
    • /
    • 2010
  • 본 논문은 다기능 미소유체시스템의 일체형 패키징을 위한 MSI (microfluidic system interface) 기술을 제안하고, 이를 설계, 제작, 시험 평가하였다. MSI 기술을 통해 플러그 방식의 유체 인터커넥터, 유체제어를 위한 미소밸브, 광학 인터페이스를 위한 광학창을 유체시스템에 일체형으로 쉽게 구현할 수 있었다. MSI 기술의 유용성을 보이기 위해 미소 유전자시료전처리시스템에 적용되었으며, 미소 유전자시료전처리시스템은 세포정제, 세포분리, 세포용해, DNA 고체상추출, 중합효소연쇄반응, 그리고 모세관전기영동 기능으로 구성되었다. 나아가 MSI 기술이 적용된 미소 유전자시료전처리시스템의 DNA 고체상추출 및 중합효소연쇄반응의 실험결과로부터 MSI가 미소유체시스템을 위한 실용적 패키징 기술임이 검증되었다.

열공압 방식의 polydimethylsiloxane 마이크로 펌프의 제작 및 특성 (Fabrication and Characteristics of Thermopneumatic-Actuated Polydimethylsiloxane Micropump)

  • 김진호;문민철;김주호;김영호;김한수;한경희;김용상
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권6호
    • /
    • pp.342-346
    • /
    • 2004
  • A thermopneumatic-actuated polydimethylsiloxane (PDMS) micropump has been fabricated and their properties are characterized. The diffusers are used as a flow-rectifying element instead of passive check valves. The advantages of the proposed microvalve are of the low cost fabrication process and the transparent optical property using PDMS and indium tin oxide (ITO) glass. We presented the PDMS micropump that is easily integrated with the in-channel PDMS microvalves on the same substrate. The flowrate of the micropump increases linearly as the applied pulse voltage to the ITO heater increases. The fabricated ITO heater resistance is 6.54k$\Omega$. The peak of the flow rate is observed at the duty ratio of 10% for the applied pulse voltage of 55V at 6Hz and the maximum flow rate of 78nl/min is measured.

자성유체의 온도에 따른 점성 변화를 이용한 미소 유체 소자 (The Microfluidic Device using Viscosity Deviation of Magnetic Fluids Due to Temperature Changes)

  • 최범규;오재근;안정재
    • 센서학회지
    • /
    • 제13권6호
    • /
    • pp.473-478
    • /
    • 2004
  • This study focused on the charateristic of magnetic fluids, the viscosity deviation of magnetic fluids due to temperature changes, and fabrication of a 'purely' liquid type microvalve. The viscosity of magnetic fluids decreases sharply during increasing of temperature. The viscosity of magnetic fluids is rated 1,000 cP at the room temperature and 25 cP when the temperature reaches $100^{\circ}C$. Briefly, it is remarkable that the fluid flow can be controlled by the temperature and this characteristic can be adopted to the microfluidics as a microvalve. The fabrication of a liquid type microvalve is more easy than solid state microvalves and which can increase an efficiency of the controlability with respect to the thermo-pneumatic micropump which is studied broadly for many years. When the magnetic fluid used as a sealant for high level sealing, the pressure leakage is less than solid state microvalve. The experimental results show that the pressure drop in microchannel, filled with the magnetic fluid, is significant in the temperature range of $20^{\circ}C{\sim}50^{\circ}C$ and this result explains why the use of magnetic fluids is possible as a microvalve searcher uses this characteristics. Well known thermo-pnumatic.

미세유체의 효율적인 액적 합류를 위한 정체현상 조절 (Stagnation of Droplet for Efficient Merging in Microfluidic System)

  • 진시형;김종민;장성찬;노영무;이창수
    • Korean Chemical Engineering Research
    • /
    • 제52권1호
    • /
    • pp.106-112
    • /
    • 2014
  • 본 연구에서는 미세액적을 효과적으로 합류시키기 위하여 미세기둥 구조들에 따른 영향 및 정체 현상 조절에 관한 연구를 수행하였다. 최적의 미세액적 합류조건을 찾기 위하여 매우 정교하게 조절이 가능한 미세 밸브를 접목하였다. 수용성 미세액적은 연속상으로 0.5 wt% Span 80이 함유된 미네랄 오일을 사용하였다. 합류과정은 미세유체 칩 내부에 위치한 미세기둥의 구조와 배치를 통해 액적 주위의 압력과 액적 내부의 라플라스 압력의 차이를 조정하여 수행된다. 마지막으로 최적의 합류 구조를 지닌 미세유체시스템에서 효소 생화학반응 실험을 수행함으로써 본 장치가 생물학 및 생화학 실험을 수행하는 유용한 도구로서 사용될 수 있음을 입증하였다.

Integrated RT-PCR Microdevice with an Immunochromatographic Strip for Colorimetric Influenza H1N1 virus detection

  • Heo, Hyun Young;Kim, Yong Tae;Chen, Yuchao;Choi, Jong Young;Seo, Tae Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.273-273
    • /
    • 2013
  • Recently, Point-of-care (POC) testing microdevices enable to do the patient monitoring, drug screening, pathogen detection in the outside of hospital. Immunochromatographic strip (ICS) is one of the diagnostic technologies which are widely applied to POC detection. Relatively low cost, simplicity to use, easy interpretations of the diagnostic results and high stability under any circumstances are representative advantages of POC diagnosis. It would provide colorimetric results more conveniently, if the genetic analysis microsystem incorporates the ICS as a detector part. In this work, we develop a reverse transcriptase-polymerase chain reaction (RT-PCR) microfluidic device integrated with a ROSGENE strip for colorimetric influenza H1N1 virus detection. The integrated RT-PCR- ROSGENE device is consist of four functional units which are a pneumatic micropump for sample loading, 2 ${\mu}L$ volume RT-PCR chamber for target gene amplification, a resistance temperature detector (RTD) electrode for temperature control, and a ROSGENE strip for target gene detection. The device was fabricated by combining four layers: First wafer is for RTD microfabrication, the second wafer is for PCR chamber at the bottom and micropump channel on the top, the third is the monolithic PDMS, and the fourth is the manifold for micropump operation. The RT-PCR was performed with subtype specific forward and reverse primers which were labeled with Texas-red, serving as a fluorescent hapten. A biotin-dUTP was used to insert biotin moieties in the PCR amplicons, during the RT-PCR. The RT-PCR amplicons were loaded in the sample application area, and they were conjugated with Au NP-labeled hapten-antibody. The test band embedded with streptavidins captures the biotin labeled amplicons and we can see violet colorimetric signals if the target gene was amplified with the control line. The off-chip RT-PCR amplicons of the influenza H1N1 virus were analyzed with a ROSGENE strip in comparison with an agarose gel electrophoresis. The intensities of test line was proportional to the template quantity and the detection sensitivity of the strip was better than that of the agarose gel. The test band of the ROSGENE strip could be observed with only 10 copies of a RNA template by the naked eyes. For the on-chip RT-PCR-ROSGENE experiments, a RT-PCR cocktail was injected into the chamber from the inlet reservoir to the waste outlet by the micro-pump actuation. After filling without bubbles inside the chamber, a RT-PCR thermal cycling was executed for 2 hours with all the microvalves closed to isolate the PCR chamber. After thermal cycling, the RT-PCR product was delivered to the attached ROSGENE strip through the outlet reservoir. After dropping 40 ${\mu}L$ of an eluant buffer at the end of the strip, the violet test line was detected as a H1N1 virus indicator, while the negative experiment only revealed a control line and while the positive experiment a control and a test line was appeared.

  • PDF