• Title/Summary/Keyword: Microfiltration Membranes

Search Result 123, Processing Time 0.028 seconds

Applicability of Temperature Correction Trans-membrane Pressure as a Fouling Index of Membrane Water Treatment Process (막여과 정수처리 공정에서 온도보정차압 식의 파울링 지표로서의 활용성 검토)

  • Kim, Minjae;Lim, Jae-Lim;Lee, Kyung-Hyuk;Lee, Young-Joo;Kim, Suhan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • Temperature correction trans-membrane pressure (TC-TMP) is frequently used as a fouling index in membrane water treatment plants. TC-TMP equation is derived based on an assumption that the total membrane resistance (i.e. the sum of the intrinsic membrane resistance and fouling resistance) is not affected by temperature. This work verified the validity of this assumption using microfiltration (MF) and ultrafiltration (UF) membranes with and without fouling. The foulants used in the work were kaolin (inorganic) and humic acid (organic). The intrinsic resistances of MF and UF membranes remains at constant values regardless of temperature change. When the same amount of foulants were accumulated on the membrane, inorganic fouling resistance with kaolin was constant regardless of temperature change while organic fouling resistance with humic acid decreased at higher temperatures, which means that TC-TMP cannot be used as a fouling index when organic fouling occurs in a real field application. Since TC-TMP underestimates the amount of fouling at higher temperatures, more attention should be necessary in the operation of membrane water treatment plant in a hotter season like summer.

Composite Membrane Preparation for Low Pressure Using Salting-Out Method and Its Application to Nanofiltration Process (염석법에 의한 저압용 역삼투막 제조 및 NF로의 적용)

  • Jeon, Yi Seul;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.25 no.5
    • /
    • pp.440-446
    • /
    • 2015
  • Nanofiltration composite membranes were prepared through the ion exchange polymers coating onto the porous microfiltration polyethylene (PE) membrane surfaces the salting-out and phase separated and pressurization (PSP) methods. The existence of coating on the surfaces was confirmed by the scanning electronic microscopy. The resulting membranes were characterized under the various conditions, such as the coating material, coating time, ionic strength etc., in terms of flux and rejection for NaCl 100 ppm solution. Under the same coating conditions of 10,000 ppm coating solution concentration and 3 atm coating pressure for both the coating materials of PEI and PSSA_MA, the flux 91.2 LMH and rejection 64.6% were obtained for PEI whereas 122.7 LMH and 38.1% were observed for PSSA_MA. From this study, it may be concluded that the composite membrane preparation is possible.

Micellar Enhanced Ceramic Microfiltration for Removal of Aqueous Ferrous Ion: Effect of Surfactant Concentration and $N_2$-back-flushing (용존 철(II) 제거를 위한 미셀형성 세라믹 정밀여과: 계면활성제 농도 및 질소 역세척의 영향)

  • Park, Jin-Yong;Kang, Sung-Gyu
    • Membrane Journal
    • /
    • v.19 no.2
    • /
    • pp.136-144
    • /
    • 2009
  • In this study, sodium dedocyl sulfate (SDS), which was anionic surfactant, was added for forming micelles to remove ferrous ions that could be contained with a small amount in industrial water. Then aggregates were formed by adsorption or binding of ferrous ions on the surface of micelles, and then rejected by ceramic membranes to remove ferrous ions. Ferrous concentration was fixed at 1mM and SDS was changed as $0{\sim}10mM$ to investigate the effect of the anionic surfactant. As a result, rejection rate of ferrous was the highest to 88.97% at 6mM. And we used ELS (Electrophoretic Light Scattering Spectrometer) to investigate particle size distribution of micellar aggregates depending on SDS concentration. Then distribution of large aggregates was the highest at 6mM. And we investigated effects of $N_2$-back-flushing time (BT) during periodic $N_2$-back-flushing on ceramic membranes. Finally optimal $N_2$-BT for NCMT-723l (pore size $0.10{\mu}m$) membrane was 20 sec.

Fabrication and Characterization of Alumina Hollow Fiber Ultrafiltration Membrane (알루미나 중공사 한외여과막 제조 및 특성평가)

  • Kim, Yeo-Jin;Kim, Seong-Joong;Kim, Jeong;Cho, Young-Hoon;Park, Hosik;Lee, Pyung-Soo;Park, You-In;Park, Ho-Bum;Nam, Seung-Eun
    • Membrane Journal
    • /
    • v.28 no.1
    • /
    • pp.21-30
    • /
    • 2018
  • In this study, homogeneous and defect-free ceramic ultrafiltration membranes were fabricated by using the sol-gel method. A boehmite sol was synthesized and coated onto the surface of alumina hollow fiber microfiltration membranes. The effect of sol viscosity and surface tension on the coating layer homogeneity and thickness was investigated. The optimum coating repetition using pristine sol was determined to be 3 times, as the samples coated more than 4 times showed delamination. Fixing the coating repetition to 3 times, the effect of sintering temperature was also studied in this work. The samples sintered at $1000^{\circ}C$ exhibited the highest pure water permeability with the molecular weight cut-off (MWCO) of approximately 51 kDa (10 nm dextran), and the samples sintered at 600, $800^{\circ}C$ displayed the MWCO of 12 kDa (5 nm dextran). The ultrafiltration membranes prepared in this work showed competitive performance compared to the reported ceramic ultrafiltration membranes.

Improving Physical Fouling Tolerance of PES Filtration Membranes by Using Double-layer Casting Methods (PES 여과막의 물리적 막오염 개선을 위한 기공 구조 개선 연구)

  • Chang-Hun Kim;Youngmin Yoo;In-Chul Kim;Seung-Eun Nam;Jung-Hyun Lee;Youngbin Baek;Young Hoon Cho
    • Membrane Journal
    • /
    • v.33 no.4
    • /
    • pp.191-200
    • /
    • 2023
  • Polyethersulfone (PES) is a widely employed membrane material for water and industrial purification applications owing to its hydrophilicity and ease of phase separation. However, PES membranes and filters prepared using the nonsolvent induced phase separation method often encounter significant flux decline due to pore clogging and cake layer formation on the dense membrane surfaces. Our investigation revealed that tight microfiltration or loose ultrafiltration membranes can be subject to physical fouling due to the formation of a dense skin layer on the bottom side caused by water intrusion to the gap between the shrank membrane and the substrate. To investigate the effect of the bottom surface porosity on membrane fouling, two membranes with the same selective layers but different sub-layer structures were prepared using single and double layer casting methods, respectively. The double layered PES membrane with highly porous bottom surface showed high flux and physical fouling tolerance compared to the pristine single layer membrane. This study highlights the importance of physical optimization of the membrane structure to prevent membrane fouling.

Treatment of Industrial Wastewater with High Concentration of Hydrocarbons Using Membrane Reactors

  • Bienati, B.;Bottino, A.;Comite, A.;Ferrari, F.;Firpo, R.;Capannelli, G.
    • Membrane Journal
    • /
    • v.17 no.2
    • /
    • pp.112-117
    • /
    • 2007
  • The application of membrane bioreactors for the depuration of wastewater coming from the washing of mineral oil storage tanks is described. Microfiltration hollow-fibre membranes were used in the submerged configuration. Filtration tests were carried out with a biomass concentration of about 15 g/L in order to assess the critical flux of the hollow fibre membrane used. Then particular care was taken in carrying out the performance runs in the sub-critical flux region. The reactor performance was very high, with removal efficiencies ranging between 93% and 97% also when the concentration of hydrocarbon was very high. Some kinetic parameters for the COD and the hydrocarbon removal were estimated.

Separation Purification Characteristics of Rinsing Solution in Semiconductor Process using Bigh Performance Polymer Membranes ( I ) (기능성 고분자막을 이용한 반도체 공정 세정액의 분리정제특성 (I))

  • Lee Jae-Dal;Hong Young-Ki;Ro Duck-Kil;Bae Kie-Seo
    • Textile Coloration and Finishing
    • /
    • v.17 no.3 s.82
    • /
    • pp.34-42
    • /
    • 2005
  • In this work, a practical separation performance was investigated on aqueous alcohol solutions, especially for iso-propyl alcohol (IPA), which is usually used during the semi- conductor rinsing process. The removal of various substances from waste aqueous IPA solutions was carried out by microfiltration with $0.1\~1{\mu}$m pore size of mean diameter as a pre-filter. Permeability and molecular weight cut-off of the functional polysulfone(PSf) ultrafiltration membrane to purify waste aqueous IPA solutions were measured through the ultrafiltration test. The solute rejection of PSf membrane had $92\%$ in 1,000ppm aqueous PEG solution with PEG molecular weight 10,000, the molecular weight cut-off had 10,000. The IPA concentration on the $CMPA-K^+$ membrane performance using pervaporation module system could be increased from $95.04 wt\%$ to more than $98.50wt\%$ in about 9hr at operation temperature of $70^{\circ}C$ using the pervaporation module system.

Separation Purification Characteristics of Rinsing Solution in Semiconductor Process using High Performance Polymer Membranes( II ) (기능성 고분자막을 이용한 반도체 공정 세정액의 분리정제특성( II ))

  • Lee Jae-Dal;Hong Young-Ki;Ro Duck-Kil;Bae Kie-Seo
    • Textile Coloration and Finishing
    • /
    • v.17 no.4 s.83
    • /
    • pp.21-26
    • /
    • 2005
  • A combination separation system is composed of three parts, simple microfiltration unit for the pretreatment of real waste IPA, pervaporation unit with plate and frame type module(the effective membrane area 9,040$cm^2$), and simple ultrafiltration unit as a refiner. Utrafiltration module with hollow fiber membrane(MWCO 10,000) used to purify waste aqueous IPA solution. In addition, the flux of $CMPA-K^+$ composite membrane for waste aqueous IPA solution was very steady-state with long experiment time(30 days). And the standard deviation($\sigma$) was 0.152 and then the coefficient of variation($CV\%$)was 10.82 The IPA concentration on the membrane performance using pervaporation module system could be increased from $89.85wt(\%)$ to more than $99.90wt\%$ in about 8hr at operation temperature of $70^{\circ}C$ using the pervaporation module system. Therefore, a combination separation process system of simple filtration and pervaporation was very effective for the purpose of the IPA purification and reuse front industrial electronic components cleaning process.

Microbial Transglutaminase의 비연속 분리공정 최적화

  • U, Dong-Jin;An, Yong-Seon;Sin, Won-Seon;Jeong, Yong-Seop;U, Geon-Jo
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.260-263
    • /
    • 2000
  • Membranes are widely used to separate target solute molecules such as proteins on the basis of their size in cell broth mixture to minimize the loss of target compounds. In this study, membrane separation system using ultrafilters of MWCO 100 K and 50 K, was operated for concentration and purification of microbial transglutaminase. Fermentation broth containing MTGase was prefiltered by using pore size 1.6 and $0.7\;{\mu}m$ pre-filter made of cellulose fiber and $0.45\;{\mu}m$ microfilter made of cellulose acetate. The prefiltered solution was concentrated by 100 K and 50 K ultrafilter. The final enzyme concentration was 1.29 units/ml and enzyme specific activity was 0.2 units/mg protein. This specific activity were 3.7 times higher than that of initial cell broth mixture. Membrane separation process of microfiltration and ultrafiltration was proved to be very economic, energy efficient and effective separation method used to concentrate MTGase.

  • PDF

A Study on the Improvement of Membrane Separation and Optimal Coagulation by Using Effluent of Sewage Treatment Plant in Busan

  • Jung, Jin-Hee;Choi, Young-Ik;Han, Young-Rip
    • Journal of Environmental Science International
    • /
    • v.22 no.10
    • /
    • pp.1353-1361
    • /
    • 2013
  • The objectives of this paper are the characterization of the pretreatment of wastewater by microfiltration (MF) membranes for river maintenance and water recycling. This is done by investigation of the proper coagulation conditions, such as the types and doses of coagulants, mixing conditions (velocity gradients and mixing periods), pH, etc., using jar tests. The effluent water from a pore control fiber (PCF) filter located after the secondary clarifier at Kang-byeon Sewage Treatment Plant (K-STP) was used in these experiments. Two established coagulants, aluminum sulfate (Alum) and poly aluminum chloride (PAC), which are commonly used in sewage treatment plants to treat drinking water, were used in this research. The results indicate that the optimal coagulation velocity gradients (G) and agitation period (T) for both Alum and PAC were 200-250 $s^{-1}$ and 5 min respectively, but the coagulation efficiencies for both Alum and PAC were lower at low values of G and T. For a 60 min filtration period on the MF, the flux efficiencies ($J/J_0$ (%)) at the K-STP effluent that were coagulated by PAC and Alum were 92.9 % and 79.9 %, respectively, under the same coagulation conditions. It is concluded that an enhanced membrane process is possible by effective filtration of effluent at the K-STP using the coagulation-membrane separation process.