• Title/Summary/Keyword: Microcontroller

Search Result 532, Processing Time 0.028 seconds

Automation of Supervision Device by the Data Logger in Distribution System (배전계통에서 Data Logger에 의한 감시장치의 자동화)

  • 문학룡;김진상;김수곤;전희종
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.3
    • /
    • pp.64-70
    • /
    • 1996
  • In this paper, we designed a low cost data logger system using single chip microcontroller. It detects the normal and abnormal current in distribution system. A sampled analog signals are stored on RAM card(4Mbit) after digitalized by internal A/D converter. Stored data can be transmitted to the personal computer either by internal serial communication port or by external parallel communication port. The transmitted data are analyzed and displayed on personal computer.

  • PDF

A New Single-Phase Asymmetrical Cascaded Multilevel DC-Link Inverter

  • Ahmed, Mahrous;Hendawi, Essam
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1504-1512
    • /
    • 2016
  • This paper presents a new single-phase asymmetrical cascaded multilevel DC-link inverter. The proposed inverter comprises two stages. The main stage of the inverter consists of multiple similar cells, each of which is a half-bridge inverter consisting of two switches and a single DC source. All cells are connected in a cascaded manner with a fixed neutral point. The DC source values are not made equal to increase the performance of the inverter. The second circuit is a folded cascaded H-bridge circuit operating at a line frequency. One of the main advantages of this proposed topology is that it is a modular type and can thus be extended to high stages without changing the configuration of the main stage circuit. Two control schemes, namely, low switching with selective harmonic elimination and sinusoidal pulse width modulation, are employed to validate the proposed topology. The detailed approach of each control scheme and switching pulses are discussed in detail. A 150W prototype of the proposed system is implemented in the laboratory to verify the validity of the proposed topology.

IGBT VVVF INVERTER AS A PROPULSION SYSTEM FOR ELECTRIC CAR (전동차 견인용 IGBT VVVF 인버터)

  • Chung, E.S.;Park, Y.H.;Jang, K.H.;Lee, S.J.;Bae, B.H.;Kim, J.S.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.373-375
    • /
    • 1997
  • In this paper, we present IGBT VVVF inverters as a 1C1M propulsion system for electric car. These inverters are composed of high power IGBT's and controlled by compact control units. The control unit performs full digital control by using 32bit DSP and microcontroller. By using CAN-bus, high speed network is constructed within four control units. The stack is simplified and optimized by using plate bus and IGBT driver units of hybrid-type.

  • PDF

A Study of Clamped-Mode Series Resonant Inverter (클램프드-모드 직렬공진형(直列共振形) 인버터에 관한 연구(硏究))

  • Kim, Pok-Kweon;Park, Jae-Cheul;Lee, Hyun-Woo;Kwon, Soon-Kurl;Suh, Ki-Young
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1161-1164
    • /
    • 1992
  • In this paper demonstrates the possibiity of utilising clamped mode - series resonant converter technology in the high frequency link inverter configuration. Main circuit of the proposed inverter is analyzed through circuit analys and waveform simulation. In control circuit PLL circuit and 8 bit single chip microcontroller is adopted, therefore flexibility and accuracy of control circuit is increased.

  • PDF

Paper Machine Industrial Analysis on Moisture Control Using BF-PSO Algorithm and Real Time Implementation Setup through Embedded Controller

  • Senthil Kumar, M.;Mahadevan, K.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.490-498
    • /
    • 2016
  • Proportional Integral Derivative (PID) controller tuning is an area of interest for researchers in many areas of science and engineering. This paper presents a new algorithm for PID controller tuning based on a combination of bacteria foraging and particle swarm optimization. BFO algorithm has recently emerged as a very powerful technique for real parameter optimization. To overcome delay in an optimization, combine the features of BFOA and PSO for tuning the PID controller. This new algorithm is proposed to combine both the algorithms to get better optimization values. The real time prototype model of paper machine is designed and controlled by using PIC microcontroller embedded with the programming in C language.

A Low-Cost Digital PWM-Controlled LED Driver with PFC and Low Light Flicker

  • Li, Yi;Lim, Jae-Woo;Kim, Hee-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2334-2342
    • /
    • 2015
  • This paper proposes an LED driving circuit with a digital controller, power factor correct (PFC) function, and low light flicker. The key topology of the proposed circuit is a conventional Flyback combined with a pre-stage. As a result, there will be less light flicker than with other one-stage PFC circuits. A digital controller, implemented using a low-cost microcontroller, dsPIC30F2020, will meet PFC and low light flicker. The experimental results validate the functionality of the proposed circuit.

Adaptive Protection Algorithm for Overcurrent Relay in Distribution System with DG

  • Sung, Byung Chul;Lee, Soo Hyoung;Park, Jung-Wook;Meliopoulos, A.P.S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1002-1011
    • /
    • 2013
  • This paper proposes the new adaptive protection algorithm for inverse-time overcurrent relays (OCRs) to ensure their proper operating time and protective coordination. The application of the proposed algorithm requires digital protection relays with microcontroller and memory. The operating parameters of digital OCRs are adjusted based on the available data whenever system conditions (system with distributed generation (DG)) vary. Moreover, it can reduce the calculation time required to determine the operating parameters for achieving its purpose. To verify its effectiveness, several case studies are performed in time-domain simulation. The results show that the proposed adaptive protection algorithm can keep the proper operating time and provide the protective coordination time interval with fast response.

A Study on the BOS control of a small PEM fuel cell stack (소형 PEM 연료전지 스택의 BOS 제어에 관한 연구)

  • Kim, Tae-Hoon;Choi, Woo-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.274-277
    • /
    • 2009
  • 본 논문에서는 소형 PEM(Proton Exchange Membrane) 연료전지 스택의 BOS(Balance of Stack) 제어에 관하여 논의한다. 별도의 가습 장치가 필요치 않고 BOS의 구성이 비교적 간단한 소형 PEM 연료전지 시스템에서는 팬과 퍼지밸브만의 제어를 통해 스택 내부 수분의 조절과 열 관리가 수행된다. 따라서 본 논문에서는 부하에 따른 최적의 공기유량을 계산하고 요구되는 유량의 공급을 위해 팬을 제어하는 알고리즘을 통해 소형 연료전지 시스템의 과도응답 특성과 안정성을 향상시키는 방법에 관하여 제안한다. 150W급 소형 연료전지 시스템을 꾸미고, 마이크로컨트롤러를 이용한 제어회로를 구현하여 실험함으로써 제안된 알고리즘의 유용함을 검증하였다.

  • PDF

Design of Monitoring System for Integrated Management of On-site Wastewater Treatment Plants and Development of its Operation Program (소규모 현장 오수처리시설의 통합관리를 위한 모니터링 시스템 설계 및 운영 프로그램 개발)

  • Cho, Young-Hyun;Kwun, Soon-Kuk
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.137-140
    • /
    • 2002
  • The monitoring system for integrated management of on-site wastewater treatment plants(biofilter) was designed and its operation program was developed. In design process, the research on monitoring parameters which will be able to represent condition and operation of the pilot plants was accomplished, and these parameters came to reveal with ORP(Oxidation-Reduction Potential), water level, pump and power on/off. Proposed monitoring system is composed with measurement, control, communication and display device, and PCB(Prototype Circuit Boards) and microcontroller (PIC16F877) technique are applied to its design of control device for performing specific function. also, The operation program of PC setup is developed in order to provide a convenience to the manager.

  • PDF

Development of Target-Controlled Infusion system in Plasma Concentration. PART2: Design and Evaluation (혈중 목표 농도 자동 조절기(TCI) 개발 PART2: 시스템 구현 및 평가)

  • 안재목
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.45-53
    • /
    • 2003
  • Based on the 4-compartmental pharmacokinetic model developed in PART1, target-controlled infusion(TCI) pump system was designed and evaluated. The TCI system consists of digital board including microcontroller and digital signal process(DSP), analog board, motor-driven actuator, user friendly interface, power management and controller. It provides two modes according to the drugs: plasma target concentration and effect target concentration. Anaesthetist controls the depth of anaesthesia for patients by adjusting the required concentration to maintain both plasma and effect site in drug concentration. The data estimated in DSP include infusion rate, initial load dose, and rotation number of motor encoder. During TCI operation, plasma concentration. effect site concentration, awaken concentration, context-sensitive decrement time and system error information are displayed in real time. Li-ion battery guarantees above 2 hours without power line failure. For high reliability of the system, two microprocessors were used to perform independent functions for both pharmacokinetic algorithm and motor control strategy.