• Title/Summary/Keyword: Membrane introduction

Search Result 112, Processing Time 0.031 seconds

Gas Permeation Properties of CO2 and CH4 for PEBAX®/Fumed Silica Hybrid Membranes (PEBAX®/fumed silica 하이브리드 분리막을 통한 CO2와 CH4의 기체투과특성)

  • Kim, Hyunjoon
    • Membrane Journal
    • /
    • v.32 no.1
    • /
    • pp.74-82
    • /
    • 2022
  • The objective of this work was to investigate the gas permeation properties of CO2 and CH4 for PEBAX®/TS-530 hybrid membranes and compare with pure PEBAX®-1657 membrane. With FTIR and XRD it was possible to confirm that TS-530 was dispersed well in PEBAX® matrix. Compared with pure PEBAX® membrane, ideal separation factor for PEBAX®/TS-530 (10 wt%) hybrid membrane was enhanced a little. As the amount of TS-530 was increased, the gas permeability coefficients of both CO2 and CH4 were increased, while the ideal separation factor was decreased. This results were explained by the reduction of crystallinity of polyamide block and interchain distance caused by introduction of inorganic nanoparticles. And fumed silica might tend to agglomerate, resulting in forming nonselective nanogaps in the hybrid materials, thus the diffusivity would be enhanced at the expense of diffusivity selectivity.

Energy Analysis in CO2 Membrane Separation Process via Heat Integration (열통합 기법을 통한 이산화탄소 막 분리공정 에너지 해석)

  • Kim, Seong Hun;Kim, Tae Yong;Kim, Beom Seok;Cho, Hyun-Jun;Yeo, Yeong Koo
    • Plant Journal
    • /
    • v.12 no.2
    • /
    • pp.24-30
    • /
    • 2016
  • The membrane separation processes have received attention due to advantages such as compactness, modularity, ease of installation, flexibility of operation, lower capital cost and lower energy consumption. In this study, we evaluated accuracy of cross-flow, co-current and counter-current models. With the most accurate model, we identified the operating conditions of the two-stage membrane separation and examined the effects of permeance and selectivity of the membrane by simulation. Futhermore, power requirements and operating cost savings due to the introduction of the heat exchanger were investigated by applying heat exchanger network synthesis technique in the two-stage membrane separation using vapor sweep.

  • PDF

Surface Modification of Polypropylene Membrane by ${\gamma}$ Irradiation Methods and their Solutes Permeation Behaviors

  • Shim, J. K.;Lee, S. H.;Kwon, O. H.;Lee, Y. M.;Nho, Y. C.
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.99-101
    • /
    • 1998
  • 1. Introduction : The conventional grafting polymerization technique requires chemically reactive groups on the surface as well as on the polymer chains. For this reason, a series of prefunctionalization steps are necessary for covalent grafting. The surface prefunctionalizational technique for grafting can be used to ionization radiation, UV, plasma, ion beam or chemical initiators. Of these techniques, radiation method is one of the useful methods because of uniform and rapid creation of active radical sites without catalytic contamination in grafted samples. If the diffusion of monomer into polymer is large enough to come to the inside of polymer substrate, a homogeneous and uniform grafting reaction can be carried out throughout the whole polymer substrate. Radiation-induced grafting method may attach specific functional moieties to a polymeric substrate, such as preirradiation and simultaneous irradiation. The former is irradiated at backbone polymer in vacuum or nitrogen gas and air, and then subsequent monomer grafting by trapped or peroxy radicals, while the latter is irradiated at backbone polymer in the presence of the monomer. Therefore, radiation-induced polymerization can be used to modification of the chemical and physical properties of the polymeric materials and has attracted considerable interest because it imparts desirable properties such as blood compatibility. membrane quality, ion excahnge, dyeability, protein adsorption, and immobilization of bioactive materials. Synthesizing biocompatible materials by radiation method such as preirradiation or simultaneous irradiation has often used $\gamma$-rays to graft hydrophilic monomers onto hydrophobic polymer substrates. In this work, in attempt to produce surfaces that show low levels of anti-fouling of bovine serum albumin(BSA) solutions, hydroxyethyl methacrylate(HEMA) was grafted polypropylene membrane surfaces by preirradiation technique. The anti-fouling effect of the polypropylene membrane after grafting was examined by permeation BSA solution.

  • PDF

A Study on the Characteristics of Anion Exchange Membrane According to Aliphatic Alkyl Chain Spacer Length Introduced into Branched Poly (Arylene Ether Sulfone) (수지상 폴리(알릴렌 이써 설폰)에 도입된 지방족 알킬사슬 연결자길이에 따른 음이온교환막의 특성 연구)

  • KIM, HYUN JIN;YOO, DONG JIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.3
    • /
    • pp.209-218
    • /
    • 2022
  • Recently, research on the development of anion exchange membranes (AEMs) has received considerable attention from the scientific community around the world. Here, we fabricated a series of AEMs with branched structures with different alkyl spacers and conducted comparative evaluations. The introduction of these branched structures is an attempt to overcome the low ionic conductivity and stability problems that AEMs are currently facing. To this end, branched polymers with different spacer lengths were synthesized and properties of each membrane prepared according to the branched structure were compared. The chemical structure of the polymer was investigated by proton nuclear magnetic resonance, Fourier transform infrared, and gel permeation chromatography, and the thermal properties were investigated using thermogravimetric analysis. The branched anion exchange membrane with (CH2)3 and (CH2)6 spacers exhibited ionic conductivities of 8.9 mS cm-1 and 22 mS cm-1 at 90℃, respectively. This means that the length of the spacer affects the ionic conductivity. Therefore, this study showing the effect of the spacer length on the ionic conductivity of the membrane in the polymer structure constituting the ion exchange membrane is judged to be very useful for future application studies of AEM fuel cells.

Preparation and Anti-fouling Properties of PVDF Mixed Matrix Asymmetric Membranes Impregnated with 𝛽-cyclodextrin (𝛽-사이클로덱스트린을 함침시킨 PVDF 혼합기질 비대칭막의 제조와 내오염성 평가)

  • Shin, Sung Ju;Lee, Jong Sung;Lee, Jeong Gil;Youm, Kyung Ho
    • Membrane Journal
    • /
    • v.31 no.6
    • /
    • pp.434-442
    • /
    • 2021
  • Poly(vinylidene fluoride) (PVDF) membrane has a good membrane durability because of its high mechanical resistance, thermal and chemical stability. However, the strong hydrophobic property of PVDF membrane can induce a low water permeability and easy fouling by proteins and organic matters. In order to improve the anti-fouling properties of PVDF membrane, the PVDF mixed matrix asymmetric membranes impregnated with biofunctional material 𝛽-cyclodextrin (𝛽-CD) in the membrane structure were prepared by phase inversion method. The membrane filtration experiments of pure water and BSA solution were performed using the PVDF/𝛽-CD mixed matrix asymmetric membranes prepared according to the 𝛽-CD contents. The experiments showed that the introduction of 𝛽-CD into the PVDF polymer matrix contributed to increase in the hydrophilic property of the PVDF membranes, and this led to the reduction of contact angles and improvement of anti-fouling properties. The PVDF/𝛽-CD membrane which was prepared using the dope solution with a 2 wt% 𝛽-CD content represented 64 L/m2·h of pure water flux, 95% of BSA rejection and maximum 80% of flux enhancements compared to flux results of the pristine PVDF membrane.

A Comparative Study of the Effects of Gibbs Smoothing Priors in Bayesian Tomographic Reconstruction (Bayesian Tomographic 재구성에 있어서 Gibbs Smoothing Priors의 효과에 대한 비교연구)

  • Lee, S.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.279-282
    • /
    • 1997
  • Bayesian reconstruction methods for emission computed tomography have been a topic of interest in recent years, partly because they allow for the introduction of prior information into the reconstruction problem. Early formulations incorporated priors that imposed simple spatial smoothness constraints on the underlying object using Gibbs priors in the form of four-nearest or eight-nearest neighbors. While these types of priors, known as "membrane" priors, are useful as stabilizers in otherwise unstable ML-EM reconstructions, more sophisticated prior models are needed to model underlying source distributions more accurately. In this work, we investigate whether the "thin plate" model has advantages over the simple Gibbs smoothing priors mentioned above. To test and compare quantitative performance of the reconstruction algorithms, we use Monte Carlo noise trials and calculate bias and variance images of reconstruction estimates. The conclusion is that the thin plate prior outperforms the membrane prior in terms of bias and variance.

  • PDF

Current Technologies and Related Issues for Mushroom Transformation

  • Kim, Sinil;Ha, Byeong-Suk;Ro, Hyeon-Su
    • Mycobiology
    • /
    • v.43 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • Mushroom transformation requires a series of experimental steps, including generation of host strains with a desirable selective marker, design of vector DNA, removal of host cell wall, introduction of foreign DNA across the cell membrane, and integration into host genomic DNA or maintenance of an autonomous vector DNA inside the host cell. This review introduces limitations and obstacles related to transformation technologies along with possible solutions. Current methods for cell wall removal and cell membrane permeabilization are summarized together with details of two popular technologies, Agrobacterium tumefaciens-mediated transformation and restriction enzyme-mediated integration.

Prediction of PolymerSolvent Diffusion Coefficients Using Free-Volume Theory (자유부피이론을 이용한 고분자/용매 확산계수의 예측)

  • 홍성욱
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.27-30
    • /
    • 1997
  • 1. Introduction : Molecular diffusion of small molecules in polymers plays an important role in many areas where polymers are acting as barriers, and in separation processes, such as selective diffusion. Different applications of polymers have different requirements on their transport properties. Therefore, reliable predictions of diffusion coefficients for small molecules in polymeric materials could be a useful tool to design appropriate materials. For many years, the theories based on free-volume concepts have been widely used to correlate and predict diffusion behavior in polymer/solvent systems. In the theory derived by Vrentas and Duda, the empty space between molecules that is available for molecular transport, referred to as hole free-volume, is being redistributed. Molecular transport will occur only when a free-volume of sufficient size appears adjacent to a molecule and the molecule has enough energy to jump into this void. The diffusive jump is considered complete when the void left behind is closed before the molecule returns to its original position. In this paper, the Vrentas-Duda free-volume theory is presented and the methods to estimate free-volume parameters for predicting polymer/ solvent diffusion coefficients are described in detail.

  • PDF

Adsorption Kinetics of Carrier-Free Yttrium-90 on Membrane Filters (막여과지에 대한 이트륨-90의 흡착 반응속도에 관한 연구)

  • Won Mok Jae
    • Journal of the Korean Chemical Society
    • /
    • v.16 no.1
    • /
    • pp.1-5
    • /
    • 1972
  • The adsorption kinetics on a membrane filter have been studied by an introduction of acid or alkali in yttrium-90 solution. The change of the adsorption in the filtration process was determined by the filtrate activities with using a microsyringe filter holder connected with a syringe. The over all reaction rate obeyed a reversible first order reaction, and the rate constants thus obtained, showed the values of $k_1$ = 0.12 $sec^{-1}$ and $k_1'$ = 0.039 $sec^{-1}$. As a result of the present studies, it would be reasonable that the rate determining step of the adsorption reaction was the hydrolysis reaction of the adsorbed yttrium ions.

  • PDF

Recent Trend of Ultra-Pure Water Producing Equipment

  • Motomura, Yoshito
    • Membrane Journal
    • /
    • v.6 no.3
    • /
    • pp.141-156
    • /
    • 1996
  • For ultra-pure water, the removal of various impirities is required, and the requirement level is rising year by year. To cope with this problem, various removing technologies and system technologies have been developed and the introduction of new materials for the piping, etc. to form the system have been positively made. For the element technologies to be used for ultra-pure water production, their range will be expanded from the technological and economic viewpoints. Therefore, it is absolutely necessary to develop trace analysis evaluation technologies for ultra-pure water. Especially to raise the analytical level of heavy metals and organic substances is important. It is also important to establish individual analysis methods of organic substances. It is expected that the analytical methods will be established and new treating methods will be put to practical use in the near future.

  • PDF