• 제목/요약/키워드: MARK3

검색결과 802건 처리시간 0.028초

사출성형 해석을 통한 Weldline 및 Flow mark 개선사례 (The Improvement of Weldline and Flow mark Defection by using Injection Molding Analysis)

  • 이영창
    • 한국정밀공학회지
    • /
    • 제30권12호
    • /
    • pp.1295-1301
    • /
    • 2013
  • The cause of flow mark defect is known as non-uniform temperature of mold surface when the flow front meets the cold cavity. The exact definition and classification of Flow mark is not clear because the mechanism of flow mark is not figured out till now. Any injection molding analysis software can not predict the flow mark phenomena. To solve weldline and flow mark defects, the gate thickness is reduced to increase the melt front velocity and the melt front velocity of the flow mark area is increased from 82.3mm/s to 104.7mm/s. In addition, the bulk temperature of the flow mark area is increased from $178.3^{\circ}C$to $215.2^{\circ}C$ by adding a cold slug well. The flow mark phenomena can be greatly reduced by increasing the flow front velocity and elevating the bulk temperature.

실리콘 웨이퍼 표면의 saw mark 밀도에 따른 피라미드 구조의 영향 (Effect on the Pyramid Structure with Saw Mark Density of Silicon Wafer Surface)

  • 이민지;박정은;이영민;강상묵;임동건
    • Current Photovoltaic Research
    • /
    • 제5권2호
    • /
    • pp.59-62
    • /
    • 2017
  • Surface texturing is affected the uniformity and size of pyramid with saw mark defect density. To analysis the influence of the saw mark defect density, we textured various si wafer. When the texturing process proceeds without the saw mark removal, silicon wafer of low-saw mark defect density showed small pyramid size of $3.5{\mu}m$ with the lowest average value of the reflectance of 10.6%. When texturing carried out after removal of the saw mark using the TMAH solution, we obtained a reflectance of about 11% and the large pyramid size of $5{\mu}m$. As a result, saw mark wafers showed a better pyramid structure than saw mark-free wafer. This result showed that saw mark can take place more smooth etching by the KOH solution and saw mark-free wafer is determined to be a factor that have a higher reflectance and a large pyramid.

2종 전자근관장측정기의 정확도 및 일관성에 관한 in vivo 연구 (In vivo evaluation of accuracy and consistency of two electronic apex locators)

  • 필감운;김의성;정일영;이승종
    • Restorative Dentistry and Endodontics
    • /
    • 제35권6호
    • /
    • pp.453-460
    • /
    • 2010
  • 연구목적: 치주질환이나 보철치료 계획으로 발치 예정인 성인 환자들을 대상으로 2 종의 전자근관장측정기를 사용하여 얻은 측정치의 정확성 (accuracy)을 평가하고, 현미경을 사용하여 각각 0.5 mark와 Apex mark 중에서 어느 지점에서 더 일관성 (consistency)을 보이는지를 비교하는 것이다. 연구 재료 및 방법: 치주 및 보철치료계획으로 인해 발거 예정인 26개의 건전한 치아들에서 13개는 Root ZX를 이용하여 측 정하였고, 나머지 13개는 i-ROOT를 이용하여 측정하였다. 국소마취를 시행 후 러버댐을 적용한 후 치아의 치수강을 개방하였다. 이때 교합면을 치아 장축에 수직으로 삭제함으로써 근관장을 측정할 때 발생할 수 있는 오차를 최소화하였다. 모든 근관에서 0.5 mark에서 먼저 근관장을 측정한 후 file을 더 전진하여 Apex mark에서 근관장을 다시 측정하였고, 이 지점에서 file을 Light cured glass ionomer로 고정하였다. 이후 치아들을 발거한 후 생리식염수에 보관하였다. 각각 치아들의 치근단부 5 mm를 21.3배율의 현미경 하에서 치근의 장축 방향으로 고속핸드피스 다이아몬드 바를 사용하여 조금씩 삭제하여 치질을 조심스럽게 제거하여 file tip을 완전히 노출시켰다. 현미경 하에서 진행한 과정들은 현미경과 연결된 DVD recorder를 통해 저장하였다. 이 이미지를 영상분석 프로그램인 i-solution에 적용하여 file tip에서부터 주근단공까지의 최단거리를 측정하였다. 결과: 1. Apex mark 이용 시 Root ZX와 i-ROOT 모두에서 주근단공 ${\pm}0.5\;mm$ 이내의 부위를 100% 찾아내는 정확도를 보였다. 2. 0.5 mark 이용 시 Root ZX에서는 100%, i-ROOT에서는 77%에서 주근단공 ${\pm}0.5\;mm$ 이내의 부위를 찾아내는 정확도를 보였다. 3. 표준편차와 사분위 값으로 평가하였을 때 Root ZX에서는 Apex mark가 0.5 mark보다 일관성을 나타냈으며 i-ROOT에서는 0.5 mark가 Apex mark보다 일관성을 보였으나 t-test 결과에서는 통계적 유의차가 없었다. 4. Apex mark와 0.5 mark 차이는 Root ZX에서는 0.22 mm, i-ROOT에서는 0.46 mm를 보였다. 결론: Apex mark와 0.5 mark 모두 일관성에 있어서의 차이는 없으나 Apex mark의 측정치가 0.5 mark에 비하면 주근단공에 거의 일치하는 점을 고려해, 임상에서 근관장을 결정할 시 Apex mark 측정치를 먼저 구한 후 기존연구들에서 보고된 주근단공에서부터 근관협착부까지의 평균거리인 0.5 mm를 빼는 것이 좋을 것으로 사료된다.

그룹 양자화를 이용한 오디오 워터마킹 기술 개발 (Development of Audio Watermarking Technique using Group Quantization)

  • 신승원;박창목;김종원;최종욱
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2002년도 하계학술발표대회 논문집 제21권 1호
    • /
    • pp.323-326
    • /
    • 2002
  • In this paper, we propose a watermarking technique that it is possible to winnow illegal contents from scattered contents on the internet. The identification is performed using an embedded unique content ID by the watermarking technique. The proposed watermarking technique accepts A/D-D/A conversion and a lot of lossy compression such as MP3, AAC, WMA and Real Audio. Watermark robustness is enabled using group quantization, selecting watermark inserting point, and error correction code. Test results show that the correct extraction is about $90\%$ and SNR is above $50\~60dB$. The above figures means that the proposed technique is able to extract encoded information at least one more times per audio and that it is very difficult to discriminate between a watermarked audio and a original audio.

  • PDF

Relationship between articulation paper mark size and percentage of force measured with computerized occlusal analysis

  • Qadeer, Sarah;Kerstein, Robert;Kim, Ryan Jin-Yung;Huh, Jung-Bo;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권1호
    • /
    • pp.7-12
    • /
    • 2012
  • PURPOSE. Articulation paper mark size is widely accepted as an indicator of forceful tooth contacts. However, mark size is indicative of contact location and surface area only, and does not quantify occlusal force. The purpose of this study is to determine if a relationship exists between the size of paper marks and the percentage of force applied to the same tooth. MATERIALS AND METHODS. Thirty dentate female subjects intercuspated into articulation paper strips to mark occlusal contacts on their maxillary posterior teeth, followed by taking photographs. Then each subject made a multi-bite digital occlusal force percentage recording. The surface area of the largest and darkest articulation paper mark (n = 240 marks) in each quadrant (n = 60 quadrants) was calculated in photographic pixels, and compared with the force percentage present on the same tooth. RESULTS. Regression analysis shows a bi-variant fit of force % on tooth (P<.05). The correlation coefficient between the mark area and the percentage of force indicated a low positive correlation. The coefficient of determination showed a low causative relationship between mark area and force ($r^2$ = 0.067). The largest paper mark in each quadrant was matched with the most forceful tooth in that same quadrant only 38.3% of time. Only 6 2/3% of mark surface area could be explained by applied occlusal force, while most of the mark area results from other factors unrelated to the applied occlusal force. CONCLUSION. The findings of this study indicate that size of articulation paper mark is an unreliable indicator of applied occlusal force, to guide treatment occlusal adjustments.

칩의 문자들을 검사하기 위한 마크 자동 검사 시스템 (A Mark Automatic Checking System to Inspect Character String on Chip)

  • 김은석
    • 한국정보통신학회논문지
    • /
    • 제11권3호
    • /
    • pp.577-583
    • /
    • 2007
  • 칩의 마크는 종류별로 다르고 매우 작아서 작업자가 육안 검사로 처리하기에는 매우 어려운 작업이다. 본 논문에서는 칩의 마크를 인식하여 잘못된 마크를 판별하는 마크 자동 검사 시스템에 대하여 제안한다. 불량항목을 검사하기 위해서 템플릿 매칭 방법과 다양한 불량 판별 조건을 사용한다. 그리고 불량판별 조건은 문자 ROI 명암도, 문자 ROI 매칭, 문자 명암도, 브로컨, 브렌치로 분류된다. 제안된 방법은 마크 불량 판별에 커다란 성능향상이 보임을 일련의 실험들을 통하여 보여준다.

맞춤형 반복교육에 따른 구강건강 관리효과 (Control Effect of Oral Health Following Individualized Repeated Instruction)

  • 조민정
    • 치위생과학회지
    • /
    • 제8권4호
    • /
    • pp.361-365
    • /
    • 2008
  • 본 연구는 환자 스스로 구강관리를 적절히 할 수 있는 기술을 익히도록 개개인을 상대로 4차례의 맞춤형 구강교육을 실시하여 성별, 나이별, 직업별, 가정의 월 평균 소득별, 학력별로 1차에서 4차까지의 치면세균막 관리점수를 산출하고, 이를 분석하여 환자의 구강관리 정도를 평가함으로서 국민 구강건강 증진을 위해 환자별 맞춤형 구강교육에 대한 기초 자료를 마련하고자 실시하였다. 1. 환자별 맞춤형 구강교육의 진행에 따라 치면세균막관리점수가 높아졌다. 2. 성별 치면세균막 관리 평균점수는 남자보다 여자의 점수가 조금 더 높았으나 큰 점수차이는 나타나지 않았다. 3. 나이별 치면세균막 관리 평균점수는 50~59세, 30~39세가 전체 치면세균막 평균점수보다 1차~4차 모두 높게 나타났으며, 20~29세, 40~49세, 60세 이상은 1~4차 모두 낮게 나타났다. 4. 직업별 치면세균막 관리 평균점수는 무직과 전문직에서 높은 점수가 나타났다. 5. 가정의 월 평균 소득별 치면세균막 관리 평균점수는 250만원 미만이 가장 높은 점수를 보였고, 250~500만원 미만이 가장 낮은 점수를 나타냈다. 6. 학력별 치면세균막 관리점수는 1차와 2차에서는 대졸이상이 가장 높은 점수를 나타냈고, 3차와 4차에서는 전문대졸 또는 대학중퇴가 높은 점수를 나타냈다.

  • PDF

PDGFC, MARK3 and BCL2 Polymorphisms are Associated with Left Ventricular Hypertrophy in Korean Population

  • Jeon, Tae-Eun;Jin, Hyun-Soek
    • 대한의생명과학회지
    • /
    • 제25권3호
    • /
    • pp.237-246
    • /
    • 2019
  • Left ventricular hypertrophy (LVH) refers to the expansion and the enlarged myocardium due to the increased resistance to ejection from the left ventricle to the aorta and/or the periphery, or the long-term burden imposed by the blood increase. Hypertension is a major risk factor that accounts for more than 50% of the causes of cardiovascular disease. If hypertension endure in the long term, the myocardium responds to abnormal heartbeat in the heart. Therefore, the prevalence of left ventricular hypertrophy also increases. As a result of genome-wide association study (GWAS) analysis for European people, PDGFC, MARK3, and BCL2 were related to blood pressures. In this study, the genetic polymorphisms of PDGFC, MARK3, and BCL2 were extracted and selected based on Korean genomic and epidemiologic data, and then logistic regression analysis was performed on LVH. As a result, one SNP (rs9307953) in PDGFC gene, four SNPs (rs6575983, rs17679475, rs2273703 and rs10141388) in MARK3 gene and two SNPs (rs17756073 and rs17070739) in BCL2 gene were statistically significant. The rs6575983 of the MARK3 gene showed the highest significance level ($P=7.2{\times}10^{-3}$) among the SNPs and the relative risk of 1.08 (95% confidence interval: 1.06 to 1.45). These results suggest that the polymorphisms of PDGFC, MARK3, and BCL2 not only affect European blood pressures but also correlate with LVH in Korean. These results suggest that increased understanding of the genetic correlations of the pathogenesis of LVH.

관광목적지의 러브마크, 브랜드 동일시, 브랜드자산 및 행동의도와의 관계 (A study on relationship among Love Marks, Brand Identification, Brand Equity & Behavior Intention)

  • 이정은;서경도
    • 디지털융복합연구
    • /
    • 제15권3호
    • /
    • pp.165-173
    • /
    • 2017
  • 본 연구는 관광목적지의 러브마크, 브랜드 동일시 및 브랜드자산 및 행동의도와의 관계를 규명하였다. 실증 분석결과는 다음과 같다. 러브마크가 자아동일시에 영향관계는 각각 러브마크의 성과는 자아동일시간의 관계, 러브마크의 친밀감은 자아동일시 순으로 유의한 관계를 나타나고 있었으며 러브마크의 신뢰는 자아동일시에는 유의한 관계를 형성하지 않고 있었다. 러브마크는 브랜드자산에 유의한 영향관계는 우선 러브마크는 브랜드품질에 유의한 영향에서 확인한 결과 친밀감과 브랜드 품질간의 관계, 신뢰와 브랜드 품질간의 관계의 순으로 유의한 관계를 형성하였으며, 성과는 브랜드 품질은 유의한 성과를 형성하지 않고 있었다. 러브마크는 브랜드가치에 유의한 영향관계에서 성과와 브랜드 가치간의 관계, 친밀감과 브랜드 가치간의 관계의 순으로 유의한 관계를 형성하였으며 성과는 브랜드 가치에 유의한 성과를 형성하지 않고 있었다. 자아일치성은 행동의도에 유의한 영향관계는 자이일치성은 행동의도간의 관계간에 유의한 관계를 형성하고 있었다. 브랜드자산은 행동의도에 유의한 영향관계는 브랜드품질과 행동의도간의 관계, 브랜드가치와 행동의도간의 관계 순으로 유의한 관계를 형성하고 있었다.

VLBI 전파 관측데이터를 위한 대용량 기록장치 비교에 관한 연구 (A Study on Comparison of Massive Data Recording Equipments for VLBI Radio Observation Data)

  • 오세진;염재환;노덕규;정동규;황주연;오충식;김효령
    • 융합신호처리학회논문지
    • /
    • 제19권3호
    • /
    • pp.125-132
    • /
    • 2018
  • KVN(Korean VLBI Network)에서는 VLBI(Very Long Baseline Interferometry) 관측을 위해 최대 32Gbps 데이터 기록을 위한 기록기로 MIT Haystack 천문대의 Mark6 시스템을 도입하였다. Mark6 기록기는 시스템 2대와 HDD가 총 64개 장착된 경우 최대 32Gbps로 데이터를 기록할 수 있다. 하지만 Mark6의 특징인 독자적인 기록방식을 사용하고 있기 때문에 대용량의 데이터를 가상 파일 시스템을 도입하거나 일반적인 RAID 방식을 사용하고 있는데, 최고 기록속도나 파일 시스템에서 파일을 읽어서 전송할 때 데이터 손실이 발생하는 문제가 있다. JIVE에서 개발한 소프트웨어 기록기인 Flexbuff 시스템은 RAID 구성과 네트워크 업그레이드를 통하여 데이터 기록기로서 동작할 수 있도록 구성할 수 있다. 특히 Mark6 시스템에 설치할 경우 Mark6의 리소스를 잘 활용하여 기존의 Mark6와 비교하여 데이터 손실이 적으면서 안정적으로 최대 32Gbps 속도로 VLBI 관측 데이터를 기록할 수 있다. 본 논문에서는 기존 Mark6 시스템에 jive5ab 소프트웨어를 설치하여 Mark6-Flexbuff로 동작할 수 있음을 제안하고, 데이터 기록시험을 통하여 VLBI 관측 운영에 효율적으로 활용할 수 있음을 시험을 통하여 확인하였다.