• 제목/요약/키워드: MARK3

검색결과 802건 처리시간 0.029초

The Improvement of Weldline and Flow mark Defection by using Injection Molding Analysis (사출성형 해석을 통한 Weldline 및 Flow mark 개선사례)

  • Lee, Yeong Chang
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제30권12호
    • /
    • pp.1295-1301
    • /
    • 2013
  • The cause of flow mark defect is known as non-uniform temperature of mold surface when the flow front meets the cold cavity. The exact definition and classification of Flow mark is not clear because the mechanism of flow mark is not figured out till now. Any injection molding analysis software can not predict the flow mark phenomena. To solve weldline and flow mark defects, the gate thickness is reduced to increase the melt front velocity and the melt front velocity of the flow mark area is increased from 82.3mm/s to 104.7mm/s. In addition, the bulk temperature of the flow mark area is increased from $178.3^{\circ}C$to $215.2^{\circ}C$ by adding a cold slug well. The flow mark phenomena can be greatly reduced by increasing the flow front velocity and elevating the bulk temperature.

Effect on the Pyramid Structure with Saw Mark Density of Silicon Wafer Surface (실리콘 웨이퍼 표면의 saw mark 밀도에 따른 피라미드 구조의 영향)

  • Lee, Min Ji;Park, Jeong Eun;Lee, Young Min;Kang, Sang Muk;Lim, Donggun
    • Current Photovoltaic Research
    • /
    • 제5권2호
    • /
    • pp.59-62
    • /
    • 2017
  • Surface texturing is affected the uniformity and size of pyramid with saw mark defect density. To analysis the influence of the saw mark defect density, we textured various si wafer. When the texturing process proceeds without the saw mark removal, silicon wafer of low-saw mark defect density showed small pyramid size of $3.5{\mu}m$ with the lowest average value of the reflectance of 10.6%. When texturing carried out after removal of the saw mark using the TMAH solution, we obtained a reflectance of about 11% and the large pyramid size of $5{\mu}m$. As a result, saw mark wafers showed a better pyramid structure than saw mark-free wafer. This result showed that saw mark can take place more smooth etching by the KOH solution and saw mark-free wafer is determined to be a factor that have a higher reflectance and a large pyramid.

In vivo evaluation of accuracy and consistency of two electronic apex locators (2종 전자근관장측정기의 정확도 및 일관성에 관한 in vivo 연구)

  • Pi, Chien-Yun;Kim, Eui-Seong;Jung, Il-Young;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • 제35권6호
    • /
    • pp.453-460
    • /
    • 2010
  • Objectives: To evaluate the accuracy and consistency of two different apex locators at both the Apex and 0.5 marks. Materials and Methods: Twenty-six root canals was scheduled for extraction for periodontal or prosthodontic reasons. Thirteen canals were measured using Root ZX and the rest by i-ROOT. The root canal length was measured both the at 0.5 mark and the Apex mark. The file was then fixed to the toot, and the distance from the file tip to the major foramen of each canal was measured after removing the root dentin under the microscope so that the major foramen and the file tip were seen. Results: 1. When the Apex mark was used, 100% of both the Root ZX and i-ROOT groups were within 0.5 mm of the major foramen. 2. When 0.5 mark was used, 100% of the Root ZX group and 77% of the i-ROOT group were within 0.5 mm of the major foramen. 3. In terms of standard deviation and quartile value, the Apex mark was more consistent than 0.5 mark in the Root ZX group, and 0.5 mark was more consistent in the i-ROOT group, but there was no statistically significant difference when compared with t-test. 4. The root canal length difference between the Apex mark and 0.5 mark was 0.22 mm and 0.46 mm in the Root ZX and i-ROOT groups, respectively. Conclusions: In this study, the Apex mark was the more consistent mark. Therefore, it is recommended to subtract 0.5 mm, which is the average length between the apex and apical constriction, from the root canal length at the Apex mark to obtain the working length clinically.

Development of Audio Watermarking Technique using Group Quantization (그룹 양자화를 이용한 오디오 워터마킹 기술 개발)

  • Shin Seungwon;Park Changmok;Kim Jongweon;Choi Jonguk
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 한국음향학회 2002년도 하계학술발표대회 논문집 제21권 1호
    • /
    • pp.323-326
    • /
    • 2002
  • In this paper, we propose a watermarking technique that it is possible to winnow illegal contents from scattered contents on the internet. The identification is performed using an embedded unique content ID by the watermarking technique. The proposed watermarking technique accepts A/D-D/A conversion and a lot of lossy compression such as MP3, AAC, WMA and Real Audio. Watermark robustness is enabled using group quantization, selecting watermark inserting point, and error correction code. Test results show that the correct extraction is about $90\%$ and SNR is above $50\~60dB$. The above figures means that the proposed technique is able to extract encoded information at least one more times per audio and that it is very difficult to discriminate between a watermarked audio and a original audio.

  • PDF

Relationship between articulation paper mark size and percentage of force measured with computerized occlusal analysis

  • Qadeer, Sarah;Kerstein, Robert;Kim, Ryan Jin-Yung;Huh, Jung-Bo;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권1호
    • /
    • pp.7-12
    • /
    • 2012
  • PURPOSE. Articulation paper mark size is widely accepted as an indicator of forceful tooth contacts. However, mark size is indicative of contact location and surface area only, and does not quantify occlusal force. The purpose of this study is to determine if a relationship exists between the size of paper marks and the percentage of force applied to the same tooth. MATERIALS AND METHODS. Thirty dentate female subjects intercuspated into articulation paper strips to mark occlusal contacts on their maxillary posterior teeth, followed by taking photographs. Then each subject made a multi-bite digital occlusal force percentage recording. The surface area of the largest and darkest articulation paper mark (n = 240 marks) in each quadrant (n = 60 quadrants) was calculated in photographic pixels, and compared with the force percentage present on the same tooth. RESULTS. Regression analysis shows a bi-variant fit of force % on tooth (P<.05). The correlation coefficient between the mark area and the percentage of force indicated a low positive correlation. The coefficient of determination showed a low causative relationship between mark area and force ($r^2$ = 0.067). The largest paper mark in each quadrant was matched with the most forceful tooth in that same quadrant only 38.3% of time. Only 6 2/3% of mark surface area could be explained by applied occlusal force, while most of the mark area results from other factors unrelated to the applied occlusal force. CONCLUSION. The findings of this study indicate that size of articulation paper mark is an unreliable indicator of applied occlusal force, to guide treatment occlusal adjustments.

A Mark Automatic Checking System to Inspect Character String on Chip (칩의 문자들을 검사하기 위한 마크 자동 검사 시스템)

  • Kim, Eun-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제11권3호
    • /
    • pp.577-583
    • /
    • 2007
  • The character strings on chips and components are so tiny and numerous that it is a very difficult work for people to perform. In this paper, we propose a mark automatic checking system, which will determine whether chip is wrong-mark or not by recognizing characters on chips. Lots of faulty detection conditions and template matching methods are used to inspect the faulty mark items. The faulty detection classifies conditions as five kinds-darkness, matching, area, broken and branch. A series of experimentation show that the method proposed here can offer an effective way to determine wrong-mark on chips.

Control Effect of Oral Health Following Individualized Repeated Instruction (맞춤형 반복교육에 따른 구강건강 관리효과)

  • Jo, Min-Jung
    • Journal of dental hygiene science
    • /
    • 제8권4호
    • /
    • pp.361-365
    • /
    • 2008
  • To educate the technique performing oral health care by oneself, four times individualized oral instruction was introduced to patients and control marks of plaque on sex, age, occupation, monthly average income, academic career were measured respectively. Through analysis of it's results and evaluation of oral health care grade on patients, this study arranged for basic data about individualized oral instruction to improve public oral health. 1. As individualized oral instruction was processed, control mark of dentalplaque improved greatly. 2. Control mark of dentalplaque on sex, female's control mark was higher than male's it. But, a gap of control mark was small. 3. Control mark of dentalplaque on age, control mark of patients in their 50s to 59s and 30s to 39s was higher than average of the whole. 4. Control mark of dentalplaque on occupation, control mark of inoccupation and professional was highly appeared. 5. Control mark of dentalplaque on monthly average income, control mark of patients whose monthly average income was below 2.5 million was highly appeared. 6. Control mark of dentalplaque on academic career, control mark of patients who graduated of university was highly appeared at first and second evaluation. On the other hand, control mark of patients who graduated of college or dropped out of university was highly appeared at third and fourth evaluation. According to the above statements, to effectively take care of oral health, our felt keenly the necessity of the individualized repeated instruction.

  • PDF

PDGFC, MARK3 and BCL2 Polymorphisms are Associated with Left Ventricular Hypertrophy in Korean Population

  • Jeon, Tae-Eun;Jin, Hyun-Soek
    • Biomedical Science Letters
    • /
    • 제25권3호
    • /
    • pp.237-246
    • /
    • 2019
  • Left ventricular hypertrophy (LVH) refers to the expansion and the enlarged myocardium due to the increased resistance to ejection from the left ventricle to the aorta and/or the periphery, or the long-term burden imposed by the blood increase. Hypertension is a major risk factor that accounts for more than 50% of the causes of cardiovascular disease. If hypertension endure in the long term, the myocardium responds to abnormal heartbeat in the heart. Therefore, the prevalence of left ventricular hypertrophy also increases. As a result of genome-wide association study (GWAS) analysis for European people, PDGFC, MARK3, and BCL2 were related to blood pressures. In this study, the genetic polymorphisms of PDGFC, MARK3, and BCL2 were extracted and selected based on Korean genomic and epidemiologic data, and then logistic regression analysis was performed on LVH. As a result, one SNP (rs9307953) in PDGFC gene, four SNPs (rs6575983, rs17679475, rs2273703 and rs10141388) in MARK3 gene and two SNPs (rs17756073 and rs17070739) in BCL2 gene were statistically significant. The rs6575983 of the MARK3 gene showed the highest significance level ($P=7.2{\times}10^{-3}$) among the SNPs and the relative risk of 1.08 (95% confidence interval: 1.06 to 1.45). These results suggest that the polymorphisms of PDGFC, MARK3, and BCL2 not only affect European blood pressures but also correlate with LVH in Korean. These results suggest that increased understanding of the genetic correlations of the pathogenesis of LVH.

A study on relationship among Love Marks, Brand Identification, Brand Equity & Behavior Intention (관광목적지의 러브마크, 브랜드 동일시, 브랜드자산 및 행동의도와의 관계)

  • Lee, Jung-Eun;Seo, Gyeong-Do
    • Journal of Digital Convergence
    • /
    • 제15권3호
    • /
    • pp.165-173
    • /
    • 2017
  • The purpose of this study was to identify the causal relationship between the brand, the brand equity and brand equity of a tourist destination. The effect of love mark on self identification is that the relationship between love mark performance and self-identification time is significant, and that of love mark is in the order of self identification. Trust mark of love mark has a significant relationship with self identification. The relationship between brand intimacy and brand quality and the relationship between trust and brand quality were significant in relation to the brand mark, but brand mark was not significant. In addition, in the relationship between brand value and love-mark, there is a significant relationship between performance and brand value, relationship between intimacy and brand value, and performance is not significant in brand value. There was a significant relationship between gender and behavioral intention. The relationship between gender identity and behavioral intention was positively related to brand equity.

A Study on Comparison of Massive Data Recording Equipments for VLBI Radio Observation Data (VLBI 전파 관측데이터를 위한 대용량 기록장치 비교에 관한 연구)

  • Oh, Se-Jin;Yeom, Jae-Hwan;Roh, Duk-Gyoo;Jung, Dong-Kyu;Hwang, Ju-Yeon;Oh, Chungsik;Kim, Hyo-Ryoung
    • Journal of the Institute of Convergence Signal Processing
    • /
    • 제19권3호
    • /
    • pp.125-132
    • /
    • 2018
  • KVN(Korean VLBI Network) introduced the Mark6 system of the MIT haystack observatory as a recorder for data recording up to 32 Gbps for VLBI(Very Long Baseline Interferometry) observation. The Mark6 recorder can record data at up to 32Gbps when two systems and 64 HDDs are installed. However, because of the unique recording method that is characteristic of Mark6, we are introducing a large amount of data into a virtual file system, or using a general RAID method, which causes data loss when reading and transferring files at the highest recording speed or file system have. The Flexbuff system, a software recorder developed by JIVE(Joint Institute for VLBI ERIC), can be configured to operate as a data recorder through RAID configuration and network upgrades. In particular, when installed in the Mark6 system, it can record VLBI data at a maximum speed of 32 Gbps with less loss of data compared to the existing Mark6 by utilizing Mark6 resources well. In this paper, we propose that the existing Mark6 system can be operated as Mark6-Flexbuff by installing jive5ab software, and it is verified through experiment that it can be effectively used for VLBI observation operation through data recording test.