• 제목/요약/키워드: MALDI MS

검색결과 333건 처리시간 0.026초

Effect of Cationization Agent Concentration on Glycan Detection Using MALDI TOF-MS

  • Kim, Inyoung;Shin, Dongwon;Paek, Jihyun;Kim, Jeongkwon
    • Mass Spectrometry Letters
    • /
    • 제8권1호
    • /
    • pp.14-17
    • /
    • 2017
  • The effect of cationization agent concentration on glycan detection via matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was investigated using $Na^+$ ions in the form of NaCl as the cationization agent. NaCl solution concentrations ranging from 1 mM to 1 M were investigated. Glycans from ovalbumin were mixed with the cationization agent solution and the 2,5-dihydroxybenzoic acid (2,5-DHB) matrix solution in a volume ratio of 1:1:1. The resulting mixture was loaded onto the MALDI plate. Two MALDI-TOF MS instruments (Voyager DE-STR MALDI-TOF MS and Tinkerbell RT MALDI-TOF MS) were used for detection of glycans. The best detection, in terms of the number of identified glycans, the peak intensity, and the signal-to-noise (S/N) ratio, was obtained with NaCl concentrations of 0.01-0.1 M for both MALDI-TOF MS instruments.

Sample Preparation for Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry

  • Kim, Jeongkwon
    • Mass Spectrometry Letters
    • /
    • 제6권2호
    • /
    • pp.27-30
    • /
    • 2015
  • This article reviews the fundamentals of sample preparation used in matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS). MALDI is a soft ionization method used to generate analyte ions in their intact forms, which are then detected in MS analysis. MALDI-MS boasts fast analysis times and easy-to-use operation. The disadvantages of MALDI-MS include the occurrence of matrix-associated peaks and inhomogeneous distribution of analyte within the matrix. To overcome the disadvantages of MALDI-MS, various efforts have been directed such as using different matrices, novel matrix systems, various additives, and different sample preparation methods. These various efforts will be discussed in detail. This article will benefit those who would like to obtain basic knowledge of MALDI sample preparation and those who would like to use MALDI-MS in their chemical analyses.

말디토프 질량분석을 이용한 고분자의 특성분석 (Analysis of Polymer Characteristics Using Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry)

  • 강민정;성윤서;김문주;김명수;변재철
    • 공업화학
    • /
    • 제28권3호
    • /
    • pp.263-271
    • /
    • 2017
  • 최근에, 질량분석기술의 폴리머 분석에의 응용은 MALDI-TOF MS 개발 이후 급속도로 발전하였다. 이 리뷰 논문은 현재까지 연구된 MALDI-TOF MS의 폴리머 특성분석에의 응용에 관한 최신 논문을 정리하였다. MALDI-TOF MS는 바이오 폴리머와, 합성 폴리머의 평균분자량 분석, 폴리머의 시퀀스 분석을 통한 구조의 해석, 모노머의 조성분석에까지 이용되고 있다. 엔드그룹의 특성과 농도를 분석하는 연구도 많이 진행되었고, 복잡한 폴리머의 분자량의 분석에는 SEC와 MALDI-TOF MS를 연결한 분석법을 추천한다. MALDI에 tandem MS를 결합한 분석기술이나, 이온 모빌리티를 응용한 질량분석기, TOF-SIMS, MALDI-TOF-Imaging 기술도 급격히 발전하고 있으며, 이의 폴리머 특성분석에의 응용은 별도의 분리기술이 필요 없어 앞으로 더 많이 이용될 것으로 생각된다. 분자량, 시퀀스, 그리고 모노머의 조성을 정확하게 계산해주는 소프트웨어와 고분자량(> 100 kDa)의 분석을 가능하게 해주는 기술이 개발된다면, 폴리머를 연구하는 과학자들에게 MALDI-TOF MS의 이용은 문제점을 해결하고, 목적하는 폴리머를 합성하는 데 중요한 수단이 될 것이다.

Applications of MALDI-TOF Mass Spectrometry in Clinical Microbiology

  • Shin, Kyeong Seob;Yum, Jonghwa
    • 대한의생명과학회지
    • /
    • 제28권3호
    • /
    • pp.145-156
    • /
    • 2022
  • Over the past few decades, few technologies have had a greater impact on clinical microbiology laboratories than matrix-assisted laser desorption time-of-flight mass spectrometry (MALDI-TOF MS). The MALDI-TOF MS is a fast, accurate, and low-cost and efficient method of microbial identification. This technology generates characteristic mass spectral fingerprints that is a unique signature for each microorganism, making it an ideal method for accurate identification at the genus and species levels of both bacterial and fastidious microorganism such as anaerobes, mycobacterium and fungi etc. In addition, MALDI-TOF MS has been successfully used in microbial subtyping and susceptibility tests such as determination of resistance genes. In this study, the authors summarized the application of MALDI-TOF MS in clinical microbiology and clinical research and explored the future of MALDI-TOF MS.

$\alpha_1$(I)및 $\alpha_2$(I)사슬 콜라겐의 질량분석법 개발 연구 (Development of mass spectrometric analysis of $\alpha_1$(I) and $\alpha_2$(I) chain Collagen)

  • 김광연;조선영;이상한;남해선;김성호
    • 한국산학기술학회논문지
    • /
    • 제6권2호
    • /
    • pp.134-143
    • /
    • 2005
  • 포유동물에서 중요한 구조단백질인 콜라겐은 다양한 조직내 단백질 조성과 사슬간 복잡한 가교결합의 존재로 인해 그 구조가 복잡하고 다양하여, 직접적으로 분석할 적당한 방법이 없었다. 본 연구에서는 간단한 전처리만으로 다수의 생체분자 시료에 대해 정확한 분자량 측정이 가능한 매트릭스 보조 레이저 탈착/이온화 비행시간 질량분석법(MALDI-TOF MS)을 이용하여 콜라겐과 조각화된 콜라겐을 분석하고 이의 아미노산 서열을 사중극자-비행시간 직렬 질량분석법(Q-TOF MS/MS)으로 확인하여, 시료 중의 콜라겐의 종류에 대한 정보를 확인하여, MALDI-TOF 질량분석을 이용한 콜라겐 분석에서 콜라겐의 종류를 쉽게 예측할 수 있는 방법을 제시하고자 하였다. 쥐의 꼬리에서 분리한 콜라겐을 SDS-PAGE로 분리한 결과 10개의 band를 얻을 수 있었는데, 같은 시료를 MALDI-TOF MS로 확인하여 각 band의 정확한 분자량을 결정할 수 있었다. SDS-PACE상의 10개의 분리된 band에 대해 각각 tryptic digestion후 MALDI-TOF 질량분석을 수행한 결과 4개의 band에서 type I 콜라겐의 $\alpha_1$-chain내의 fragment인 Gly1056-Arg1073을 확인할 수 있었고, 5개의 band에서 type I 콜라겐의 $\alpha_2$-chain내의 fragment인 Gly985-Arg1002을 확인하였다. 잔재한 콜라겐의 가교결합으로 인해 예상되는 fragment중 둘만이 확인되었지만, 확인된 fragment를 통해 적어도 7개의 band에서는 type I콜라겐이 존재함을 확인할 수 있었다. 확인된 두 콜라겐 flagment의 아미노산 서열을 Q-TOF MS/MS로 분석한 결과 MALDI-TOF MS에서의 예측과 일치함을 확인할 수 있었으며, 이를 통해 확인된 두 fragment에 의한 peak을 지문으로 하여 MALDI-TOF MS측정시에 시료내의 type I 콜라겐의 존재를 쉽게 확인할 수 있음을 볼 수 있었다.

  • PDF

Development of a Matrix-prespotted Plate for Enhancing the Reproducibility of Serum Glycan Analysis by MALDI-TOF-MS

  • Ha, Mi-Young;In, Young-Ha;Maeng, Hye-Sun;Zee, Ok-Pyo;Lee, Jong-Sik;Kim, Yang-Sun
    • Mass Spectrometry Letters
    • /
    • 제2권3호
    • /
    • pp.61-64
    • /
    • 2011
  • Matrix Assisted Laser Desorption/Ionization-Time-of-Flight mass spectrometry (MALDI-TOF-MS) is the most widely used MS technique for glycan analysis. However, the poor point-to-point and sample-to-sample reproducibility becomes a limit in glycan biomarker research. A prespotted MALDI plate which overcomes the large crystal formation of 2,5-dihydroxybenzoic acid (DHB) has been developed and applied for glycan analysis. A homogeneous matrix coated surface without a crystal structure was formed on a hydrophilic/ hydrophobic patterned surface using a piezoelectric device. The reproducible MALDI-TOF-MS data have been presented using MALDI imaging of beer glycan as well as serum glycan eluted from 10% and 20% ACN elution fractions. The glycan profile from the serum glycan by MALDI-TOF-MS with a DHB prespotted plate was highly conserved for 10 different spectra and the coefficient of variations of significant ion peaks of MALDI data varies from 3.59 to 19.95.

A MALDI-MS-based Glucan Hydrolase Assay Method for Whole-cell Biocatalysis

  • Ahn, Da-Hee;Park, Han-Gyu;Song, Won-Suk;Kim, Seong-Min;Jo, Sung-Hyun;Yang, Yung-Hun;Kim, Yun-Gon
    • 한국미생물·생명공학회지
    • /
    • 제47권1호
    • /
    • pp.69-77
    • /
    • 2019
  • Screening microorganisms that can produce glucan hydrolases for industrial, environmental, and biomedical applications is important. Herein, we describe a novel approach to perform glucan hydrolase screening-based on analysis of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) spectra-which involves degradation of the oligo- and polysaccharides. As a proof-of-concept study, glucan hydrolases that could break down glucans made of several glucose units were used to demonstrate the MALDI-MS-based enzyme assay. First, the enzyme activities of ${\alpha}$-amylase and cellulase on a mixture of glucan oligosaccharides were successfully discriminated, where changes of the MALDI-MS profiles directly reflected the glucan hydrolase activities. Next, we validated that this MALDI-MS-based enzyme assay could be applied to glucan polysaccharides (i.e., pullulan, lichenan, and schizophyllan). Finally, the bacterial glucan hydrolase activities were screened on 96-well plate-based platforms, using cell lysates or samples of secreted enzyme. Our results demonstrated that the MALDI-MS-based enzyme assay system would be useful for investigating bacterial glucoside hydrolases in a high-throughput manner.

Screening Analysis of 10 Adrenal Steroids by Matrix-Assisted Laser Desorption Ionization-Tandem Mass Spectrometry

  • Kim, Sun-Ju;Jung, Hyun-Jin;Chung, Bong-Chul;Choi, Man-Ho
    • Mass Spectrometry Letters
    • /
    • 제2권3호
    • /
    • pp.69-72
    • /
    • 2011
  • Defective synthesis of the steroid hormones by the adrenal cortex has profound effects on human development and homeostasis. Due to the time-consuming chromatography procedure combined with mass spectrometry, the matrix-assisted laser desorption ionization method coupled to the linear ion-trap tandem mass spectrometry (MALDI-LTQ-MS/MS) was developed for quantitative analysis of 10 adrenal steroids in human serum. Although MALDI-MS can be introduced for its applicability as a high-throughput screening method, it has a limitation on reproducibility within and between samples, which renders poor reproducibility for quantification. For quantitative MALDI-MS/MS analysis, the stable-isotope labeled internal standards were used and the conditions of crystallization were tested. The precision and accuracy were 3.1~35.5% and 83.8~138.5%, respectively, when a mixture of 10 mg/mL ${\alpha}$-cyano-4-hydroxycinnamic acid in 0.2% TFA of 70% acetonitrile was used as the MALDI matrix. The limit of quantification ranged from 5 to 340 ng/mL, and the linearity as a correlation coefficient was higher than 0.988 for all analytes in the calibration range. Clinical applications include quantitative analyses of patients with congenital adrenal hyperplasia. The devised MALDI-MS/MS technique could be successfully applied to diagnosis of clinical samples.

MALDI-MS: A Powerful but Underutilized Mass Spectrometric Technique for Exosome Research

  • Jalaludin, Iqbal;Lubman, David M.;Kim, Jeongkwon
    • Mass Spectrometry Letters
    • /
    • 제12권3호
    • /
    • pp.93-105
    • /
    • 2021
  • Exosomes have gained the attention of the scientific community because of their role in facilitating intercellular communication, which is critical in disease monitoring and drug delivery research. Exosome research has grown significantly in recent decades, with a focus on the development of various technologies for isolating and characterizing exosomes. Among these efforts is the use of matrix-assisted laser desorption ionization (MALDI) mass spectrometry (MS), which offers high-throughput direct analysis while also being cost and time effective. MALDI is used less frequently in exosome research than electrospray ionization due to the diverse population of extracellular vesicles and the impurity of isolated products, both of which necessitate chromatographic separation prior to MS analysis. However, MALDI-MS is a more appropriate instrument for the analytical approach to patient therapy, given it allows for fast and label-free analysis. There is a huge drive to explore MALDI-MS in exosome research because the technology holds great potential, most notably in biomarker discovery. With methods such as fingerprint analysis, OMICs profiling, and statistical analysis, the search for biomarkers could be much more efficient. In this review, we highlight the potential of MALDI-MS as a tool for investigating exosomes and some of the possible strategies that can be implemented based on prior research.

돼지유래 Salmonella속 균의 동정을 위한 MALDI TOF MS 활용 (MALDI TOF MS for the identification of Salmonella spp. from swine)

  • 손준형;전우진;이영미;김선수
    • 한국동물위생학회지
    • /
    • 제39권4호
    • /
    • pp.247-251
    • /
    • 2016
  • Salmonella is one of the most common bacteria that causes heavy losses in swine industry and major causative pathogen of food poisoning in public health. Various methods for the identification of Salmonella such as Gram staining, agglutination test, enzyme-linked immunosorbent assay (ELISA), polymerase chain reaction (PCR) have been used. Several studies have demonstrated that Matrix Assisted Laser Desorption Ionization Time of Flight (MALDI TOF) Mass Spectrometry (MS) identification is an efficient and inexpensive method for the rapid and routine identification of isolated bacteria. In this study, MALDI TOF MS could provide rapid, accurate identification of Salmonella spp. from swine compared with end point PCR and real time PCR.