• Title/Summary/Keyword: Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

Search Result 292, Processing Time 0.039 seconds

Determination of Glimepiride in Human Plasma by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry

  • Kim, Ho-Hyun;Chang, Kyu-Young;Lee, Hee-Joo;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.1
    • /
    • pp.109-114
    • /
    • 2004
  • A sensitive method for quantitation of glimepiride in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Glipizide was used as an internal standard. Glimepiride and internal standard in plasma sample was extracted using diethyl etherethyl acetate (1 : 1). A centrifuged upper layer was then evaporated and reconstituted with the mobile phase of acetonitrile-5 mM ammonium acetate (60:40, pH 3.0). The reconstituted samples were injected into a $C_{18}$ reversed-phase column. Using MS/MS in the multiple reaction monitoring (MRM) mode, glimepiride and glipizide were detected without severe interference from human plasma matrix. Glimepiride produced a protonated precursor ion ([M+H]$^+$) at m/z 491 and a corresponding product ion at m/z 352. And the internal standard produced a protonated precursor ion ([M+H]]$^+$) at m/z 446 and a corresponding product ion at m/z 321. Detection of glimepiride in human plasma by the LC-ESI/MS/MS method was accurate and precise with a quantitation limit of 0.1 ng/mL. The validation, reproducibility, stability, and recovery of the method were evaluated. The method has been successfully applied to pharmacokinetic studies of glimepiride in human plasma.

Simultaneous Determination of Phenobarbital, Pentobarbital, Amobarbital and Secobarbital in Raw Milk via Liquid Chromatography with Electron Spray Ionization Tandem Mass Spectrometry

  • Tian, Huaixiang;Zhou, Xingxin;Chen, Chen;He, Yabin;Yu, Haiyan;Zheng, Xiaoping
    • Food Science of Animal Resources
    • /
    • v.37 no.6
    • /
    • pp.847-854
    • /
    • 2017
  • A rapid, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous determination of four barbiturates (phenobarbital, pentobarbital, amobarbital and secobarbital) in raw milk. The barbiturates were extracted using liquid-liquid extraction, ultrasonication and centrifugation, and purified on an SPE column. Analytes were separated by HPLC on a CSH C18 column eluted using an acetonitrile-water system with a linear gradient dilution programme, and detected by MS/MS. The recoveries of the barbiturates were 85.0-113.5%, and the intra- and inter-assay RSDs were less than 9.8% and 7.3%, respectively. The limit of detection was 5 ng/mL for all four of the barbiturates. The analytical method exhibited good linearity from 10 to 1000 ng/mL; the correlation coefficient ($r^2$) was greater than 0.9950 for each barbiturate. This method was also applied to the determination of barbiturates in real milk samples and was found to be suitable for the determination of veterinary drug residues in raw milk.

Rapid Determination of L-carnitine in Infant and Toddler Formulas by Liquid Chromatography Tandem Mass Spectrometry

  • Ahn, Jang-Hyuk;Kwak, Byung-Man;Park, Jung-Min;Kim, Na-Kyeoung;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.34 no.6
    • /
    • pp.749-756
    • /
    • 2014
  • A rapid and simple analytical method for L-carnitine was developed for infant and toddler formulas by liquid chromatography tandem mass spectrometry (LC-MS/MS). A 0.3 g of infant formula and toddler formula sample was mixed in a 50 mL conical tube with 9 mL water and 1 mL 0.1 M hydrochloric acid (HCl) to chemical extraction. Then, chloroform was used for removing a lipid fraction. After centrifuged, L-carnitine was separated and quantified using LC-MS/MS with electrospray ionization (ESI) mode. The precursor ion for L-carnitine was m/z 162, and product ions were m/z 103 (quantitative) and m/z 85 (qualitative), respectively. The results for spiked recovery test were in the range of 93.18-95.64% and the result for certified reference material (SRM 1849a) was within the range of the certificated values. This method could be implemented in many laboratories that require time and labor saving.

Development of Sensitive Analytical Method of Rhodanthpyrone A by a LC-MS/MS and its Application to Bioavailability Study in Rats

  • Kang, Bitna;Yoon, Jeong A;Song, Im-Sook;Han, Young Taek;Choi, Min-Koo
    • Mass Spectrometry Letters
    • /
    • v.10 no.3
    • /
    • pp.88-92
    • /
    • 2019
  • A sensitive analytical method of rhodanthpyrone A in rat plasma was developed using a liquid chromatography-tandem mass spectrometry (LC-MS/MS). Rhodanthpyrone A and rhodanthpyrone B (internal standard) in rat plasma were extracted by a liquid-liquid extraction method with ethyl acetate. This extraction method gave results in high and reproducible extraction recovery in the range of 73.75-79.90% with no interfering peaks around the peak elution time of rhodanthpyrone A and B. The standard calibration curves for rhodanthpyrone A ranged from 0.5 to 2000 ng/mL were linear with $r^2$ > 0.994 and the inter- and intra-day accuracy and precision and the stability were within acceptance criteria. Using this validated analytical method, pharmacokinetics of rhodanthpyrone A following intravenous and oral administration of rhodanthpyrone A at doses of 2 mg/kg and 30 mg/kg, respectively, were investigated. Rhodanthpyrone A in rat plasma showed multi-exponential elimination pattern with high clearance and volume of distribution values. The absolute oral bioavailability of this compound was calculated as 3.7%. Collectively, the newly developed sensitive LC-MS/MS analytical method of rhodanthpyrone A could be successfully applied to investigate the pharmacokinetic properties of this compound and would be useful for the further studies on the efficacy, toxicity, and biopharmaceutics of rhodanthpyrone A.

Determination of Grayanotoxin I and Grayanotoxin III in mad honey from Nepal using liquid chromatography-tandem mass spectrometry

  • Ahn, Su Youn;Kim, Suncheun;Cho, Hwangeui
    • Analytical Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.82-91
    • /
    • 2022
  • Grayanotoxin-contaminated honey exhibits toxicity. In this study, a reliable and sensitive liquid-chromatography-tandem-mass-spectrometric method (LC-MS/MS) was developed and validated for the quantitation of grayanotoxin I and grayanotoxin III in honey. The grayanotoxins were extracted from honey via solid phase extraction and separated on a biphenyl column with a mobile phase consisting of 0.5 % acetic acid in water and methanol. Mass spectrometric detection was performed in the multiple-reaction monitoring mode with positive electrospray ionization. The calibration curve covered the range 0.25 to 100 ㎍/g. The intra- and inter-day deviations were less than 10.6 %, and the accuracy was between 94.3 and 114.0 %. The validated method was successfully applied to the determination of grayanotoxins in mad honey from Nepal. The concentrations of grayanotoxin I and grayanotoxin III in 33 out of 60 mad honey samples were 0.75 - 64.86 ㎍/g and 0.25 - 63.99 ㎍/g, respectively. The method established herein would help in preventing and confirming grayanotoxin poisoning.

Development of Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry as a Candidate Reference Method for the Determination of Folic Acid in Infant Milk Formula

  • Jung, Min-Young;Kim, Byung-Joo;Boo, Doo-Wan;So, Hun-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.745-750
    • /
    • 2007
  • An isotope dilution-liquid chromatography/tandem mass spectrometric method was developed as a candidate reference method for the accurate determination of folic acid in infant milk formula. Sample was spiked with 13C5-folic acid and then extracted with phosphate buffer (pH 6) solution. The extract was further cleaned up by deproteinization followed by a C18 solid-phase extraction cartridge. The extract was analyzed by using LC/ ESI/MS/MS with selectively monitoring the collisionally induced dissociation channels of m/z 442 → m/z 295 and m/z 447 → m/z 295, which are the neutral glutamyl loss from the [M+H]+ ions of folic acid and 13C5-folic acid, respectively. LC/MS/MS chromatograms showed substantially reduced background from chemical noises compared to LC/MS chromatograms. Repeatability and reproducibility studies showed that the LC/MS/ MS method is a reliable and reproducible method which can provide less than 1.5 relative percentage of method precision.

Optimization of Solid Phase Extraction Method for Quantitative Analysis of Perfluorooctanoic Acid in Serum using Liquid Chromatography-Tandem Mass Spectrometry

  • Lee, Hyun-Seok;Yim, Yong-Hyeon
    • Mass Spectrometry Letters
    • /
    • v.5 no.1
    • /
    • pp.30-33
    • /
    • 2014
  • A solid phase extraction (SPE) method was optimized for the quantitative analysis of perfluorooctanoic acid (PFOA) in serum using hydrophilic-lipophilic balance SPE and LC-MS/MS. Fetal bovine serums spiked with $^{13}C_8$-PFOA before or after SPE were used as test samples for evaluation of the SPE efficiency. Simultaneous evaluation of matrix effects and absolute SPE recovery for $^{13}C_8$-PFOA in serum using different sample pre-treatments and SPE conditions allowed optimization of SPE process efficiency with minimal matrix effect and decent SPE recovery. Introduction of protein precipitation as a sample pre-treatment procedure for serum samples before SPE generally decreased matrix effect in LC-MS/MS analysis and provided more stable recovery of PFOA.

Analysis of LC-MS/MS in Discrimination of the Origin of Commercial Red Ginseng Concentrates (시판 홍삼농축액의 원산지 판별을 위한 LC-MS/MS 분석)

  • Moon, Ji Young;Han, Hyun Jung;Dong, Hyemin;Park, Su Won;Kim, Hyun Jung;Bang, Kyong-Hwan;Noh, Bong Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.46 no.5
    • /
    • pp.549-555
    • /
    • 2014
  • The geographical origin of commercial red ginseng concentrate was studied using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The ginsenoside content of domestic and Chinese red ginseng concentrates was determined. Four types of suspected origin samples could be selected this technique. The LC-MS/MS data were statistically analyzed on the basis of canonical function analysis and principal component analysis. Domestic and Chinese samples could be discriminated via canonical function analysis using posterior probability. In addition, the mixture ratio (Korean or Chinese origin) of the unknown origin specimen could be predicted based on the relationship between the mixing concentration of red ginseng concentrates and principal component 1.

Liquid Chromatography-Tandem Mass Spectrometry for the Determination of Lithospermic Acid B in Rat Serum

  • Kim, Hui-Hyun;Ji, Hye-Young;Lee, Hye-Won;Kim, Youn-Chul;Sohn, Dong-Hwan;Lee , Hye-Suk
    • Archives of Pharmacal Research
    • /
    • v.27 no.12
    • /
    • pp.1202-1206
    • /
    • 2004
  • A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC-MS/ MS) method for the determination of lithospermic acid B (LSB) in rat serum was developed. LSB and internal standard, 7-hydroxy-3-phenyl-chromen-4-one (HPC) were extracted from rat serum with methyl-tert-butyl ether at acidic pH and analyzed on a Luna $C_8$ column with the mobile phase of acetonitrile-ammonium formate (10 mM, pH 6.5) (50:50, v/v). The analytes were detected using a negative electrospray ionization tandem mass spectrometry in the multiple- reaction-monitoring mode. The standard curve was linear $(r^2 = 0.997)$ over the concentration range of 10.0-500 ng/mL. The coefficient of variation and relative error for intra- and interassay at three QC levels were 1.1~6.2% and -10.3~-2.7%, respectively. The recovery of LSB from serum sample ranged from 73.2 to 79.5%, with that of HPC (internal standard) being 75.1 %. The lower limit of quantification for LSB was 10 ng/mL using 50 ${\mu}L$ of serum sample.

Tetramine Analysis using Liquid Chromatography-Tandem Mass Spectrometry and Ion Chromatography (LC-MS/MS와 Ion Chromatography를 이용한 테트라민 분석)

  • Song, Ki-Cheol;Lee, Ka-Jeong;Kim, Ji-Hoe;Yoon, Ho-Dong;Yu, Hong-Sik;Mok, Jong-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.44 no.1
    • /
    • pp.45-49
    • /
    • 2011
  • As a first step toward identifying a new method for testing sea snail tissue for toxins, and thus prevent food poisoning due to the ingestion of contaminated snails, we measured the tetramine [$(CH_3)_4N^+$] contents of sea snails from the Korean coast using both liquid chromatography-tandem mass spectrometry (LC-MS/MS) and ion chromatography. For tetramine tested, good linearity ($r^2$ = 0.9996) was observed between the amounts in the injected samples and the peak areas of standard toxins, which ranged from 0.1 to 100 ng. The recovery (%) of tetramine from spiked tissue and mid-gut gland samples ranged from 84.0 to 95.3%. The quantitative results for tetramine using this method were in good agreement with the theoretical values. LC-MS/MS has both high sensitivity and selectivity, which makes it possible to measure trace quantities of tetramine in samples.