A sensitive method for quantitation of glimepiride in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Glipizide was used as an internal standard. Glimepiride and internal standard in plasma sample was extracted using diethyl etherethyl acetate (1 : 1). A centrifuged upper layer was then evaporated and reconstituted with the mobile phase of acetonitrile-5 mM ammonium acetate (60:40, pH 3.0). The reconstituted samples were injected into a $C_{18}$ reversed-phase column. Using MS/MS in the multiple reaction monitoring (MRM) mode, glimepiride and glipizide were detected without severe interference from human plasma matrix. Glimepiride produced a protonated precursor ion ([M+H]$^+$) at m/z 491 and a corresponding product ion at m/z 352. And the internal standard produced a protonated precursor ion ([M+H]]$^+$) at m/z 446 and a corresponding product ion at m/z 321. Detection of glimepiride in human plasma by the LC-ESI/MS/MS method was accurate and precise with a quantitation limit of 0.1 ng/mL. The validation, reproducibility, stability, and recovery of the method were evaluated. The method has been successfully applied to pharmacokinetic studies of glimepiride in human plasma.
Keywords
Glimepiride; Glipizide; Liquid-liquid extraction; Liquid chromatography; Tandem mass spectrometry;
Citations & Related Records

Times Cited By Web Of Science : 8  (Related Records In Web of Science)
Times Cited By SCOPUS : 7
연도 인용수 순위
1 Lehr, K.; Damm, P. J. Chromatogr. 1990, 526, 497-505.   DOI   ScienceOn
2 Magni, F.; Marazzini, L.; Pereira, S.; Monti, L.; Galli, K. M. Anal.Biochem. 2000, 282, 136-141.   DOI   ScienceOn
3 Henion, J.; Brewer, E.; Rule, G. Anal. Chem. 1998, 70, 650A-656A.   DOI   ScienceOn
4 Kolterman, Q.; Gray, R. S. Diabetes 1984, 32, 346-354.
5 Drager, K. E. Horm. Metab. Res. 1996, 28, 419-425.   DOI   ScienceOn
6 Roche, M. E.; Oda, R. P.; Lawson, G. M.; Landers, J. P.Electrophoresis 1997, 18, 1865-1874.   DOI   ScienceOn
7 Altinoz, S.; Tekeli, D. J. Pharm. Biomed. Anal. 2001, 24, 507-515.   DOI   ScienceOn
8 Sonenberg, G. E. Am. Pharmacother. 1997, 37, 671-676.
9 Lo, D. S.; Chao, T. C.; Ng Ong, S. E.; Yao, Y. J.; Koh, T. H.Forensic Sci. Int. 1997, 90, 205-214.   DOI   ScienceOn
10 Drummer, O. H.; Kotsos, A.; McIntyre, I. M. J. Anal. Toxicol.1993, 17, 225-229.   DOI   ScienceOn
11 Nunez, M.; Ferguson, J. E.; Machacek, D.; Jacob, G.; Oda, R. P.;Lawson, G. M.; Landers, J. P. Anal. Chem. 1995, 67, 3668-3675.   DOI   ScienceOn
12 King, R.; Bonfiglio, R.; Fernandez-Metzler, C.; Miller-Stein, C.;Olah, T. J. Amer. Soc. Mass. Spectrom. 2000, 11, 942-950.   DOI   ScienceOn