• Title/Summary/Keyword: Linearity Error

Search Result 289, Processing Time 0.033 seconds

I/Q channel 12-Bit 120MHz CMOS D/A Converter for WLAN (무선랜용 I/Q 채널 12bit 120MHz CMOS D/A 변환기 설계)

  • Ha, Sung-Min;Nam, Tae-Kyu;Seo, Sung-Uk;Shin, Sun-Hwa;Joo, Chan-Yang;Yoon, Kwang-S.
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.11 s.353
    • /
    • pp.83-89
    • /
    • 2006
  • This paper describes the design of I/Q channel 12bit Digital-to-Analog Converter(DAC) which shows the conversion rate of 120MHz and the power supply of 3.3V with 0.35um CMOS n-well 1-poly 4-metal process for advanced wireless transceiver. The proposed DAC utilizes 4-bit thermometer decoder with 3 stages for minimum glitch energy and linearity error. Also, using a optimized 4bit thermometer decoder for the decrement of the chip area. Integral nonlinearity(INL) of ${\pm}1.6LSB$ and differential nonlinearity(DNL) of ${\pm}1.3LSB$ have been measured. In single tone test, the ENOB of the proposed 12bit DAC is 10.5bit and SFDR of 73dB(@ Fs=120MHz, Fin=1MHz) is measured, respectively. Dual-tone test SFDR is 61 dB (@ Fs=100MHz, Fin=1.5MHz, 2MHz). Glitch energy of 31 pV.s is measured. The converter consumes a total of 105mW from 3.3-V power supply.

An 1.2V 8-bit 800MSPS CMOS A/D Converter with an Odd Number of Folding Block (홀수개의 폴딩 블록으로 구현된 1.2V 8-bit 800MSPS CMOS A/D 변환기)

  • Lee, Dong-Heon;Moon, Jun-Ho;Song, Min-Kyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.7
    • /
    • pp.61-69
    • /
    • 2010
  • In this paper, an 1.2V 8b 800MSPS A/D Converter(ADC) with an odd number of folding block to overcome the asymmetrical boundary-condition error is described. The architecture of the proposed ADC is based on a cascaded folding architecture using resistive interpolation technique for low power consumption and high input frequency. The ADC employs a novel odd folding block to improve the distortion of signal linearity and to reduce the offset errors. In the digital block, furthermore, we use a ROM encoder to convert a none-$2^n$-period code into the binary code. The chip has been fabricated with an $0.13{\mu}m$ 1P6M CMOS technology. The effective chip area is $870{\mu}m\times980{\mu}m$. SNDR is 44.84dB (ENOB 7.15bit) and SFDR is 52.17dBc, when the input frequency is 10MHz at sampling frequency of 800MHz.

A Signal Readout System for CNT Sensor Arrays (CNT 센서 어레이를 위한 신호 검출 시스템)

  • Shin, Young-San;Wee, Jae-Kyung;Song, In-Chae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.9
    • /
    • pp.31-39
    • /
    • 2011
  • In this paper, we propose a signal readout system with small area and low power consumption for CNT sensor arrays. The proposed system consists of signal readout circuitry, a digital controller, and UART I/O. The key components of the signal readout circuitry are 64 transimpedance amplifiers (TIA) and SAR-ADC with 11-bit resolution. The TIA adopts an active input current mirror (AICM) for voltage biasing and current amplification of a sensor. The proposed architecture can reduce area and power without sampling rate degradation because the 64 TIAs share a variable gain amplifier (VGA) which needs large area and high power due to resistive feedback. In addition, the SAR-ADC is designed for low power with modified algorithm where the operation of the lower bits can be skipped according to an input voltage level. The operation of ADC is controlled by a digital controller based on UART protocol. The data of ADC can be monitored on a computer terminal. The signal readout circuitry was designed with 0.13${\mu}m$ CMOS technology. It occupies the area of 0.173 $mm^2$ and consumes 77.06${\mu}W$ at the conversion rate of 640 samples/s. According to measurement, the linearity error is under 5.3% in the input sensing current range of 10nA - 10${\mu}A$. The UART I/O and the digital controller were designed with 0.18${\mu}m$ CMOS technology and their area is 0.251 $mm^2$.

Performance Evaluation of Hazardous Substances using Measurement Vehicle of Field Mode through Emergency Response of Chemical Incidents

  • Lee, Yeon-Hee;Hwang, Seung-Ryul;Kim, Jae-Young;Kim, Kyun;Kwak, Ji Hyun;Kim, Min Sun;Park, Joong Don;Jeon, Junho;Kim, Ki Joon;Lee, Jin Hwan
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.4
    • /
    • pp.294-302
    • /
    • 2015
  • BACKGROUND: Chemical accidents have increased owing to chemical usage, human error and technical failures during the last decades. Many countries have organized supervisory authorities in charge of enforcing related rules and regulations to prevent chemical accidents. A very important part in chemical accidents has been coping with comprehensive first aid tool. Therefore, the present research has provided information with the initial applications concern to the rapid analysis of hazardous material using instruments in vehicle of field mode after chemical accidents. METHODS AND RESULTS: Mobile measurement vehicle was manufactured to obtain information regarding field assessments of chemical accidents. This vehicle was equipped with four instruments including gas chromatography with mass spectrometry (GC/MS), Fourier Transform Infrared Spectroscopy (FT-IR), Ion Chromatography (IC), and UV/Vis spectrometer (UV) to analyses of accident preparedness substances, volatile compounds, and organic gases. Moreover, this work was the first examined the evaluation of applicability for analysis instruments using 20 chemicals in various accident preparedness substances (GC/MS; 6 chemicals, FT-IR; 2 chemicals, IC; 11 chemicals, and UV; 1 chemical) and their calibration curves were obtained with high linearity ( r 2 > 0.991). Our results were observed the advantage of the high chromatographic peak capacity, fast analysis, and good sensitivity as well as resolution. CONCLUSION: When chemical accidents are occurred, the posted measurement vehicle may be utilized as tool an effective for qualitative and quantitative information in the scene of an accident owing to the rapid analysis of hazardous material.

Improvement of the Method using the Coefficient of Variation for Automatic Multi-segmentation Method of a Rating Curve (수위-유량관계곡선의 자동구간분할을 위한 변동계수 활용기법의 개선)

  • Kim, Yeonsu;Kim, Jeongyup;An, Hyunuk;Jung, Kwansue
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.10
    • /
    • pp.807-816
    • /
    • 2015
  • In general, the water stage-discharge relationship curve is established based on the assumptions of linearity and homoscedasticity. However, the relationship between the water stage and discharge is affected from geomorphological factors, which violates the basic assumptions of the water stage-discharge relationship curve. In order to reduce the error due to the violations, the curve is divided into several sections based on the manager's judgement considering change of cross-sectional shape. In this research, the objective-splitting criteria of the curve is proposed based on the measured data without the subjective decision. First, it is assumed that the coefficient of variation follows the normal distribution. Then, if the newly calculated coefficient of variation is outside of the 95% confidential interval, the curve is divided. Namely, the groups is divided by the characteristics of the coefficient of variation and the reasonable criteria is provided for establishing a multi-segmented rating curve. To validate the proposed method, it was applied to the data generated by three artificial power functions. In addition, to confirm the applicability of the proposed method, it is applied to the water stage and discharge data of the Muju water stage gauging station and Sangegyo water stage gauging station. As a result, it is found that the automatically divided rating curve improves the accuracy and extrapolation accuracy of the rating curve. Finally, through the residual analysis using Shapiro-Wilk normality test, it is confirmed that the residual of water stage-discharge relationship curve tends to follow the normal distribution.

A Design of Novel Instrumentation Amplifier Using a Fully-Differential Linear OTA (완전-차동 선형 OTA를 사용한 새로운 계측 증폭기 설계)

  • Cha, Hyeong-Woo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.1
    • /
    • pp.59-67
    • /
    • 2016
  • A novel instrumentation amplifier (IA) using fully-differential linear operational transconductance amplifier (FLOTA) for electronic measurement systems with low cost, wideband, and gain control with wide range is designed. The IA consists of a FLOTA, two resistor, and an operational amplifier(op-amp). The principal of the operating is that the difference of two input voltages applied into FLOTA converts into two same difference currents, and then these current drive resistor of (+) terminal and feedback resistor of op-amp to obtain output voltage. To verify operating principal of the IA, we designed the FLOTA and realized the IA used commercial op-amp LF356. Simulation results show that the FLOTA has linearity error of 0.1% and offset current of 2.1uA at input dynamic range ${\pm}3.0V$. The IA had wide gain range from -20dB to 60dB by variation of only one resistor and -3dB frequency for the 60dB was 10MHz. The proposed IA also has merits without matching of external resistor and controllable offset voltage using the other resistor. The power dissipation of the IA is 105mW at supply voltage of ${\pm}5V$.

Field-Programmable Gate Array-based Time-to-Digital Converter using Pulse-train Input Method for Large Dynamic Range (시간 측정범위 향상을 위한 펄스 트레인 입력 방식의 field-programmable gate array 기반 시간-디지털 변환기)

  • Kim, Do-hyung;Lim, Han-sang
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.6
    • /
    • pp.137-143
    • /
    • 2015
  • A delay-line type time-to-digital converter (TDC) implemented in a field-programmable gate array (FPGA) is most widely owing due to its simple structure and high conversion rate. However, the delay-line type TDC suffers from nonlinearity error caused by the long delay-line because its time interval measurement range is determined by the length of the used delay line. In this study, a new TDC structure with a shorter delay line by taking a pulse train as an input is proposed for improved time accuracy and efficient use of resources. The proposed TDC utilizes a pulse-train with four transitions and a transition state detector that identifies the used transition among four transitions and prevents the meta-stable state without a synchronizer. With 72 delay cells, the measured resolution and maximum non-linearity were 20.53 ps, and 1.46 LSB, respectively, and the time interval measurement range was 5070 ps which was enhanced by approximately 343 % compared to the conventional delay-line type TDC.

Realization of sensitivity symmetry of Hall Sensor using Trench Structure and Ferromagnetic Thin Films (트랜치 구조 및 강자성체 박막을 이용한 홀 센서의 감도 대칭성 구현)

  • Park, Jae-Sung;Choi, Chae-Hyoung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.4
    • /
    • pp.29-34
    • /
    • 2008
  • Generally, for conventional 3-D Hall sensor it is general that the sensitivity for $B_z$ is about 1/10 compared with those for $B_x$ or $B_y$. Therefore, in this work, we proposed 3-D Hall sensor with new structures. We have increased the sensitivity about 6 times to form the trench using anisotropic etching. And we have increased the sensitivity for the $B_z$ by 80 % compared with those of $B_x$ and $B_y$ using deposition of the ferromagnetic thin films on the bottom surface of the wafer to concentrate the magnetic fluxes. Sensitivities of the fabricated sensor with Ni/Fe film for $B_x,\;B_y$, and $B_z$ were measured as 361mV/T, 335mV/T, and 286mV/T, respectively. It has also showed sine wave of Hall voltages over a $360^{\circ}$ rotation. A packaged sensing part was $1.2{\times}1.2mm^2$. The measured linearity of the sensor was within ${\pm}3%$ of error. Resolution of the fabricated sensor was measured by $1{\times}10^{-5}T$.

Determination of PFOS in LDPE and the Result for Proficiency Testing (LDPE 중 PFOS의 분석법 개발과 비교숙련도 결과)

  • Jung, Jae Hak;Lee, Young Kyu;Myung, Seung Woon;Cheong, Nam Yong
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.1
    • /
    • pp.40-51
    • /
    • 2013
  • In order to develop a quantitation method for Perfluorooctanesulfonic acid(PFOS) contained in plastics that are mainly used in electric and electronic equipment, this study consisted of conducting method validations with LDPE samples using soxhlet solvent extraction and LC/MS. As a result, the limits of detection and quantitation (LOD, LOQ) were $2.58{\mu}g/L$ and $7.82{\mu}g/L$, respectively. Additionally, the recovery was 96-102%. For the correlation coefficient of LC/MS, the $r^2$ value was 0.9992 in the concentration range of $7.82-100{\mu}g/L$, which confirmed its linearity. Furthermore, for the standardization of the analysis method for PFOS in electric and electronic equipment to correspond to EU environmental regulations, we conducted a proficiency test with a number of domestic and international testing laboratories. Three of the ten testing laboratories that participated in the proficiency test submitted outliers. Accordingly, we examined the cause of the outliers using the $^{19}F$ NMR, finding that the main cause was an error in the processing of the results for isomers in PFOS that existed in standard solutions and samples.

Comparison of Linac-based VMAT Stereotatic Radiosurgery and Conventional Stereotatic Radiosurgery for Multiple Brain Lesions (Linac 기반 VMAT 정위적 수술 뇌 병변 연구와 기존의 정위적 방사선 수술 비교)

  • Jang, Eun-Sung;Chang, Bo-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.239-246
    • /
    • 2021
  • Portal Dosimetry was verified using EPID to secure the clinical application and reliability of the existing research dose evaluation. The dose distribution of Geant4 was compared with the measured value by 360° rotational irradiation with a 2.5 cm cone for stereotactic brain surgery. To confirm the dose distribution of patients with brain metastasis, the dose distribution investigated by inserting a Gafchromic EBT film into the parietal phantom and the dose distribution obtained from the parietal phantom using VMAT are compared and applied to actual patients. As a result of the analysis, it was confirmed that the accuracy of the beam center and the center of the couch coincide accurately with an error within 1mm as a result of QA through a pin ball. In addition, it was confirmed that the EBT3 film has excellent linearity in the range of 0 to 10 Gy according to various dose irradiation. In the same setting as the two cervical phantoms, we confirm that the implementation and simulation results calculations of dose calculations based on Geant4 using photon beams match the experimental data within the treatment planning volume (PTV). Therefore, volume modulated arc treatment (VMAT) 360° rotational irradiation was performed, and the result of iso-dose distribution analysis by rotational irradiation confirmed that it is appropriate to include a virtual tumor.