• Title/Summary/Keyword: Leakage inductance

Search Result 242, Processing Time 0.029 seconds

New On-line Tuning Scheme of Inductances for Induction Motors in Field Weakening Region (약계자 영역에서 유동전동기 인덕턴스의 새로운 온라인 동조방법)

  • 김하용;신명호;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.209-214
    • /
    • 1999
  • New estimation and tuning schemes of inductance variations for rotor flux oriented (RFO) control of induction motor in field weakening region are presented. Stator transient inductance and stator self inductance are estimated. From estimated stator self inductance. magnetizing inductance is estimated and from estimated stator transient inductance, rotor leakage inductance is estimated. Simulation and experimental results prove the effectiveness of the proposed s scheme in constant torque and field weakening region.

  • PDF

Analysis and Design of Quadruple-Active-Bridge Converter Employing Passive Power Decoupling Capability (수동 전력 비동조화가 가능한 QAB 컨버터의 분석과 설계에 관한 연구)

  • Yun, Chang-Woo;Lee, Jun-Young;Baek, Ju-Won;Jung, Jee-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.2
    • /
    • pp.157-164
    • /
    • 2022
  • This study proposes an enhanced quadruple-Active-Bridge (QAB) converter that can solve power coupling problems. By adopting a multiple winding transformer, the equivalent circuit of a conventional QAB converter has power couplings between arbitrary output ports. This coupling is an unintended power relationship that complicates the regulation of output voltage of the multiple ports. The proposed converter can carry out power decoupling by changing the arrangement of the coupling inductor. Power transfer equations for the proposed converter and its operating principles are analyzed in detail. The power coupling caused by the transformer's leakage inductance is verified by using a proposed coupling factor that presents the relationship between inductance ratio and coupling power. In addition, the decoupling power control performance of the proposed converter is verified by simulation and a 3 kW prototype converter.

The Study on the One-stage PFC-flyback Converter using the Soft Switching Technique (소프트 스위칭 기법을 이용한 1단 PFC-flyback 컨버터)

  • Lee, Sang-Hyeok;Hwang, Jung-Goo;Park, Sung-Jun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.263-269
    • /
    • 2013
  • The flyback converter has been applied widely in isolated DC/DC power converters because this converters employ a single MOSFET switch. The leakage inductance should be minimized for high efficiency of flyback converter. but in reality, it is very difficult. Namely, The Snubber circuit is essential to recover the leakage inductance stored energy when the switch is turn off. Flyback Converter typically operates in DCM mode and when switch is turn off in hard switching, this hard switching action results in a high power losses and switching stresses. In order to overcome these problems, a novel soft switching flyback converter using resonant snubber circuit is proposed in this paper. The resonant snubber circuit is composed of the transformer leakage inductance and a capacitor. To verify and confirm the proposed resonant snubber circuit, PSIM simulation and hardware prototype are implemented. Simulation and Experimental results indicate that the proposed resonant snubber circuit is effective.

Novel Single Switch DC-DC Converter for High Step-Up Conversion Ratio

  • Hu, Xuefeng;Gao, Benbao;Huang, Yuanyuan;Chen, Hao
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.662-671
    • /
    • 2018
  • This paper presents a new structure for a step up dc-dc converter, which has several advantageous features. Firstly, the input dc source and the clamped capacitor are connected in series to transfer energy to the load through dual voltage multiplier cells. Therefore, the proposed converter can produce a very high voltage and a high conversion efficiency. Secondly, a double voltage clamped circuit is introduced to the primary side of the coupled inductor. The energy of the leakage inductance of the coupled inductor is recycled and the inrush current problem of the clamped circuits can be shared equally by two synchronous clamped capacitors. Therefore, the voltage spike of the switch tube is solved and the current stress of the diode is reduced. Thirdly, dual voltage multiplier cells can absorb the leakage inductance energy of the secondary side of the coupled inductor to obtain a higher efficiency. Fourthly, the active switch turns on at almost zero current and the reverse-recovery problem of the diodes is alleviated due to the leakage inductance, which further improves the conversion efficiency. The operating principles and a steady-state analysis of the continuous, discontinuous and boundary conduction modes are discussed in detail. Finally, the validity of this topology is confirmed by experimental results.

A Study on the Soft-Switching Forward-Flyback Converter Using Auxiliary Inductor and Auxiliary Diode (보조 인덕터와 보조 다이오드를 적용한 소프트-스위칭이 가능한 포워드-플라이백 컨버터에 관한 연구)

  • Lee, A-Ra;Park, Jun-Woo;Hong, Sung-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.2
    • /
    • pp.140-149
    • /
    • 2017
  • This study proposes a new type of active-clamp forward-flyback converter with two transformers that operate in forward and flyback modes during on and off times, respectively, instead of not using an output inductor. The main switch can be turned on with zero-voltage switching (ZVS) using the leakage inductance of the transformer and the output capacitor of the main switch. The leakage inductance should be increased to ZVS. However, the ringing between the leakage inductance of the transformer and the parasitic output capacitance of the secondary side rectifier switches results in a serious voltage spike. A forward-flyback converter employing auxiliary inductor and auxiliary diode is proposed to overcome the problem. The operational principles are analyzed in detail and validated through experiments with a 385 V-to-53 V/37 A prototype.

Novel Adaptive Blanking Regulation Scheme for Constant Current and Constant Voltage Primary-side Controlled Flyback Converter

  • Bai, Yongjiang;Chen, Wenjie;Yang, Xiaoyu;Yang, Xu
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1469-1479
    • /
    • 2017
  • Primary-side regulation (PSR) scheme is widely applied in low power applications, such as cell phone chargers, network adapters, and LED drivers. However, the efficiency and standby power requirements have been improved to a high standard due to the new trends of DOE (Department Of Energy) Level VI and COC (Code Of Conduct specifications) V5. The major drawbacks of PSR include poor regulation due to inaccurate feedback and difficulty in acquiring acceptable regulation. A novel adaptive blanking strategy for constant current and constant voltage regulation is proposed in this paper. An accurate model for the sample blanking time related to transformer leakage inductance and the metal-oxide-semiconductor field-effect transistor (MOSFET) parasitic capacitance is established. The proposed strategy can achieve accurate detection for ultra-low standby power. In addition, numerous control factors are analyzed in detail to eliminate the influence of leakage inductance on the loop stability. A dedicated controller integrated circuit (IC) with a power MOSFET is fabricated to verify the effectiveness of the proposed control strategy. Experimental results demonstrated that the prototype based on the proposed IC has excellent performance.

Leakage Inductance Estimation of $Y-\triangle$ Transformer Using the Least Square Method (최소자승법을 이용한 $Y-\triangle$ 누설 인덕턴스 추정 방법)

  • Hwang, Tae-Keun;Lee, Byung-Eun;Jang, Sung-Il;Kim, Yong-Gyun;Kang, Yong-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.645-650
    • /
    • 2007
  • This paper proposes a parameter estimation technique of a power transformer. Based on the combined equation, it estimates separately the primary and secondary leakage inductances using the least square method from the instantaneous voltages and currents in the steady state. The performance of the proposed technique was investigated by varying the cut-off frequency of the filter and the number of samples per cycle. The estimated values are obtained based on the average value for 41 cycle.

The Calculation Method of Leakage Inductances in Electrical Machines Using F.E.M. (유한요소법을 이용한 전기기기의 누설인덕턴스 계산)

  • Kim, Hyung-Seok;Choi, Myoung-Jun;Park, Il-Han
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.18-20
    • /
    • 1995
  • In this paper we presented a calculation method of leakage inductance in electrical machines. For its accurate calculation the finite element method is applied to the analysis of magnetic field distribution. The self and mutual inductances are derived using the results of the magnetic field analysis and the leakage inductance is easily obtained from these inductances. As numerical examples, we tread a single phase transformer and a rotor slot model of induction motor. In the finite element analysis we used the 2D linear magnetostatic formulation with the first-order triangular element.

  • PDF

Phase Shift Full Bridge Converter for Sever Power using a New Separated Leakage Inductor Winding (SLW) Method

  • Cho, Kyu-Min;Kim, Young-Do;Cho, In-Ho;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.517-519
    • /
    • 2008
  • A new transformer winding method is proposed in this paper. Generally, PWM ZVS topologies use a leakage inductor to achieve ZVS operation. However, the leakage inductance of the transformer is not often enough to meet ZVS condition. Therefore, an additional leakage inductor is necessary, which causes large core loss because high input voltage is applied to the additional leakage inductor during a short commutation period. In this paper, a new separated leakage inductor winding (SLW) method is proposed. With the proposed winding method, a leakage inductor and a transformer can be combined in one ferrite core. Therefore, size and core loss of the additional leakage inductor can be reduced. Experimental results demonstrate that the proposed winding method can achieve a significant efficiency improvement in a 1210.8W (12V, 100.9A) prototype converter.

  • PDF

An Improved High Efficiency Resonant Converter for the Contactless Power Supply with a Low Coupling Transformer (낮은 커플링 변압기를 갖는 비접촉 전원의 개선된 고효율 공진 컨버터)

  • Kong Young-Su;Kim Eun-Soo;Lee Hyun-Kwan
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.1
    • /
    • pp.33-39
    • /
    • 2005
  • Comparing with the conventional transformer without the air gap, a contactless transformer with the large air gap between the long primary winding and the secondary winding has increased leakage inductance and reduced magnetizing inductance. For transferring the primary power to the secondary one, the high frequency series resonant converter has been widely used for the contactless power supply system with the large air gap and the increased leakage inductance of the contactless transformer However, the high frequency series resonant converter has the disadvantages of the low efficiency and high voltage gain characteristics in the overall load range due to the large air gap and the circulating magnetizing current. In this paper, the characteristics of the high efficiency and unit voltage gain are revealed in the proposed three-level series-parallel resonant converter. The results are verified on the simulation based on the theoretical analysis and the 5kW experimental prototype.