• Title/Summary/Keyword: LOGGING

Search Result 674, Processing Time 0.025 seconds

A Load Emulator for Low-power Embedded Systems and Its Application (저전력 내장형 시스템을 위한 부하의 전력 소모 에뮬레이션 시스템과 응용)

  • Kim, Kwan-Ho;Chang, Nae-Hyuck
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.6
    • /
    • pp.37-48
    • /
    • 2005
  • The efficiency of power supply circuits such as DC-DC converters and batteries varies on the trend of the power consumption because their efficiencies are not fixed. To analyze the efficiency of power supply circuits, we need the temporal behavior of the power consumption of the loads, which is dependent on the activity factors of the devices during the operation. Since it is not easy to model every detail of those factors, one of the most accurate power consumption analyses of power supply circuits is measurement of a real system, which is expensive and time consuming. In this paper, we introduce an active load emulator for embedded systems which is capable of power measurement, logging, replaying and synthesis. We adopt a pattern recognition technique for data compression in that long-term behaviors of power consumption consist of numbers of repetitions of short-term behaviors, and the number of short-term behaviors is generally limited to a small number. We also devise a heterogeneous structure of active load elements so that low-speed, high-current active load elements and high-speed, low-current active load elements may emulate large amount and fast changing power consumption of digital systems. For the performance evaluation of our load emulator, we demonstrate power measurement and emulation of a hard drive. As an application of our load emulator, it is used for the analysis of a DC-DC converter efficiency and for the verification of a low-power frequency scaling policy for a real-time task.

Evaluation of Grouting Effect by Injection Materials Using Geophysical Logging (물리검층을 이용한 주입재에 따른 그라우팅 효과 판정)

  • Choe, Jeong-Yeol;Park, Sang-Gyu;Im, Guk-Muk;Song, Mu-Yeong
    • 한국지구과학회:학술대회논문집
    • /
    • 2010.04a
    • /
    • pp.98-98
    • /
    • 2010
  • 그라우팅은 지반의 공학적인 강도증가를 통한 지지력 향상 및 암반의 투수성 저감을 통해 지하수 유동을 억제하기 위하여 대규모 토목공사 현장의 균열암반 및 댐 또는 제방 등의 지역에서 많이 시행되고 있다. 본 연구는 균열암반지역에서 그라우팅 효과 확인을 위하여 보통 포틀랜드 시멘트(OPC)와 마이크로 시멘트(MC)를 사용하여 그라우팅을 수행하였으며, 그라우팅 전후에 물리검층(시추공영상촬영, 초음파 텔레뷰어검층)을 이용하여 그라우팅 효과 정도를 파악하였다. 연구지역은 경상북도 영주시 평은면 지역으로, 지질은 선캠브리아기 안구상편마암에 시대미상의 흑운모 화강암이 관입을 하였고, 이를 제4기의 충적층이 부정합으로 피복되어 있다. 그라우팅은 일반구간과 단층대구간으로 구분하여 실시하였으며, 두 구간의 이격거리는 서로의 간섭을 피하기 위해 약 40m 간격으로 선정하였다. 주입재(OPC, MC)는 5개의 주입공에서 triangle 방향으로 주입하였으며, 주입정도를 확인하기 위하여 각 구간에 2공씩 확인시추를 하였다. 두 개의 site중 일반구간의 보통 포틀랜드시멘트 주입결과 평균주입량은 48.2kg/공이며 주입 1m당으로 환산하면 Lugeon값 10미만의 지층에서는 1.62kg/m이며, 마이크로시멘트의 평균주입량은 49.6kg/공이며 주입 1m당으로 환산하면 Lugeon값 10미만의 지층에서는 3.86kg/m로 나타났다. 단층대 구간에서는 보통 포틀랜드시멘트의 평균주입량이 40.0kg/공이며, 1m당으로 환산하면 Lugeon값 10미만의 지층에서는 2.75kg/m이며, 마이크로 시멘트는 평균주입량이 56.5kg/공, 주입 1m당으로 환산하면 Lugeon값 10미만의 지층에서는 3.15kg/m로 나타났다. 마이크로시멘트의 주입압은 보통 포틀랜드시멘트에 비해 상대적으로 낮았으며, 그라우팅 개선효과 역시 상대적으로 양호한 것으로 나타났다. 그라우팅 효과확인을 위한 물리검층의 초음파텔레뷰어 해석결과 상대암반강도는 주입전 $250{\sim}750\;kgf/cm^2$, 주입후는 $400{\sim}800\;kgf/cm^2$으로 그라우팅에 의한 암반강도의 상승을 확인할 수 있었고, 시추공영상촬영 분석에서는 시추코어만으로 얻기 힘든 시멘트 충진구간을 직접 확인할 수 있었다. 초음파텔레뷰어의 경우 파쇄대의 분포 및 암반강도 측정을 통한 그라우팅 파악은 가능하였으나 파쇄대 충진물을 확인할 수가 없는 단점이 있었고 이를 시추공영상촬영을 통해 보완할 수 있었다. 다만 물리검층의 경우 그라우팅에 의한 공의 손실로 동일공에 의한 반복 조사가 아닌 경우가 대부분이어서 그라우팅 효과에 대한 정확한 비교가 어려웠으며 추후 이를 보완하기 위한 계속적인 연구가 필요할 것으로 사료된다.

  • PDF

Performance Enhancement Architecture for HLR System Based on Distributed Mobile Embedded System (분산 모바일 임베디드 시스템 기반의 새로운 위치정보 관리 시스템)

  • Kim Jang Hwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.12B
    • /
    • pp.1022-1036
    • /
    • 2004
  • In mobile cellular network the ever-changing location of a mobile host necessitates the continuous tracking of its current position and efficient management of location information. A database called Home Location Register(HLR) plays a major role in location management in this distributed environment, providing table management, index management, and backup management facilities. The objectives of this paper are to identify the p개blems of the current HLR system through rigorous analysis, to suggest solutions to them, and to propose a new architecture for the HLR system. In the HLR system, a main memory database system is used to provide real-time accesses and updates of subscriber's information. Thus it is suggested that the improvement bemade to support better real-time facilities, to manage subscriber's information more reliably, and to accommodate more subscribers. In this paper, I propose an efficient backup method that takes into account the characteristics of HLR database transactions. The retrieval speed and the memory usage of the two-level index method are better than those of the T-tree index method. Insertion md deletion overhead of the chained bucket hashing method is less than that of modified linear hashing method. In the proposed backup method, I use two kinds of dirty flags in order to solve the performance degradation problem caused by frequent registration-location operations. Performance analysis has been performed to evaluate the proposed techniques based on a system with subscribers. The results show that, in comparison with the current techniques, the memory requirement is reduced by more than 62%,directory operations, and backup operation by more than 80%.

Basic Study on the Characteristics of Wooden Sidewalk Pavement Material using Wood Waste Chip (폐목재 칩을 활용한 목질계 보도포장재의 특성에 대한 기초연구)

  • Choi, Jae Jin;Song, Jin Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3D
    • /
    • pp.413-420
    • /
    • 2011
  • An experiment was conducted to suggest the road pavement material combining wooden chip crushed from little useful roots and branches from logging sites or wood waste from construction sites with urethane resin. For the specimen, the mass ratio of urethane resin to construction wood waste chip/lumber waster chip was set to three different levels of 0.5, 0.75, and 1.0, which was measured, mixed with mixer, and molded; 7 days after, tensile strength test, elasticity test using golf balls and steel balls, permeability coefficient measurement, and flammability test were executed. As the result, the tensile strength of the specimen at the dry state in the air exhibited the range of 0.2-1.1MPa, and there was no change after 7 days of aging. When submerged in water, however, the strength was partially diminished; the diminishing rate was greater for less urethane resin usage, and therefore it appears desirable to set the mass ratio of resin to the wood waste chip over 0.75 to consider the moisture intrusion by precipitation and such. As the result of elasticity test, the GB and SB coefficients of the specimen using wood waste chips and urethane resin were measured to be low at below 20%, exhibiting excellent elasticity as road pavement material. Also, the permeability coefficient was over 0.5mm/sec for specimens of all combinations, exceeding the standard value required after construction for permeable pavement material, and the flammability of wood-type pavement material was evaluated to have no practical issues.

Case histories on design alternatives during excavation of underground LPG storage cavern and traffic tunnel using TSP survey (TSP 탐사를 이용한 지하유류저장공동 및 도로터널의 시공 중 설계변경 사례 고찰)

  • Cha Sung-Soo;Kim Se-Hoon;Yun Sang-Pil;Bae Jung-Sik;Lee Jin-Moo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 1999.08a
    • /
    • pp.117-136
    • /
    • 1999
  • The geophysical survey at pre-investigation stage can hardly provide the detailed information on geological structure of site which has difficulty in access and thick overburden. The TSP (VSP applied in tunnel) survey at post-investigation stage can show the detailed geology ahead of tunnel and around cavern. The TSP survey was carried out at the Pyongtaek LPG storage cavern site during the cavern excavation and provided the location and orientation of the fault inferred below Namyangho. In order to confirm the result of TSP survey four boreholes were drilled in access tunnel. The fault was also detected by borehole survey and the location was coincided with the result of TSP survey. Depend on the result of TSP survey and core logging, the design such as cavern layout and length could have been changed. As another case history the TSP survey was performed at the Mumeuje road tunnel which has poor geological information due to thick overburden. The support design was also changed on the base of TSP survey.

  • PDF

Principles and application of DC resistivity tomography and borehole radar survey. (전기비저항 토모그래피와 시추공 레이다 탐사의 원리 및 응용)

  • Kim Jung-Ho;Yi Myeong-Jong;Cho Seong-Jun;Song Yoon-Ho;Chung Seung-Hwan
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 1999.08a
    • /
    • pp.92-116
    • /
    • 1999
  • Tomographic approaches to image underground structure using electrical properties, can be divided into DC resistivity, electromagnetic, and radar tomography, based on the operating frequency. DC resistivity and radar tomography methods have been recently applied to site investigation for engineering purpose in Korea. This paper review these two tomography methods, through the case histories acquired in Korea. As another method of borehole radar survey, borehole radar reflection method is included, and its inherent problem and solution are discussed, how to find the azimuth angle of reflector using direction-finding-antenna. Since the velocity anisotropy of radar wave has been commonly encountered in field data, anisotropic radar tomography is discussed in this paper. In DC resistivity tomography, two subjects are focussed, electrode arrays, and borehole effect owing to the conductive fluid in borehole. Using the numerical modeling data, various kinds of electrode ways are compared, and borehole effect is illustrated. Most of the case histories presented in this paper are compared with known geology, core logging data, and/or Televiewer images.

  • PDF

Interpretation on the subsurface velocity structure by seismic refraction survey in tunnel and slope (탄성파 굴절법 탐사를 이용한 지반 속도분포 해석-터널 및 절토 사면에의 적용 사례)

  • You Youngjune;Cho Chang Soo;Park Yong Soo;Yoo In Kol
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 1999.08a
    • /
    • pp.48-64
    • /
    • 1999
  • For quantitative evaluation of geotechnical engineering properties such as rippability and diggability, clear interpretation on the subsurface velocity structures should be preceded by figuring out top soil, weathered and soft rock layers, shape of basement, fracture zones, geologic boundary and etc. from the seismic refraction data. It is very important to set up suitable field parameters, which are the configuration of profile and its length, spacings of geophones and sources and topographic conditions, for increasing field data quality Geophone spacing of 3 to 5m is recommended in the land slope area for house land development and 5 to 10m in the tunnel site. In refraction tomography technique, the number of source points should be more than a half of available channel number of instrument, which can make topographic effect ignorable. Compared with core logging data, it is shown that the velocity range of the soil is less than 700m/s, weathered rock 700${\~}$1,200m/s, soft rock 1,200${\~}$1,800m/s. And the upper limit of P-wave velocity for rippability is estimated 1,200 to 1,800m/s in land slope area of gneiss. In case of tunnel site, it is recommended in tunnel design and construction to consider that tunnel is in contact with soft rock layer where three lineaments intersecting each other are recognized from the results of the other survey.

  • PDF

The e-Business Component Construction based on Distributed Component Specification (분산 컴포넌트 명세를 통한 e-비즈니스 컴포넌트 구축)

  • Kim, Haeng-Gon;Choe, Ha-Jeong;Han, Eun-Ju
    • The KIPS Transactions:PartD
    • /
    • v.8D no.6
    • /
    • pp.705-714
    • /
    • 2001
  • The computing systems of today expanded business trade and distributed business process Internet. More and more systems are developed from components with exactly reusability, independency, and portability. Component based development is focused on advanced concepts rater than passive manipulation or source code in class library. The primary component construction in CBD. However, lead to an additional cost for reconstructing the new component with CBD model. It also difficult to serve component information with rapidly and exactly, which normalization model are not established, frequency user logging in Web caused overload. A lot of difficult issues and aspects of Component Based Development have to be investigated to develop good component-based products. There is no established normalization model which will guarantee a proper treatment of components. This paper elaborates on some of those aspects of web application to adapt user requirement with exactly and rapidly. Distributed components in this paper are used in the most tiny size on network and suggest the network-addressable interface based on business domain. We also discuss the internal and external specifications for grasping component internal and external relations of user requirements to be analyzed. The specifications are stored on Servlets after dividing the information between session and entity as an EJB (Enterprise JavaBeans) that are reusable unit size in business domain. The reusable units are used in business component through query to get business component. As a major contribution, we propose a systems model for registration, auto-arrange, search, test, and download component, which covers component reusability and component customization.

  • PDF

A Case Study on Seismic Refraction Tomography Survey for Subsurface Structure Interpretation (지하구조 해석을 위한 탄성파 굴절법 토모그라피 탐사 사례연구)

  • 유영준;유인걸;송무영
    • The Journal of Engineering Geology
    • /
    • v.11 no.2
    • /
    • pp.163-174
    • /
    • 2001
  • For quantitative evaluation of geotechnical engineering properties such as rippability and diggability, clear interpretation on the subsUJiace velocity structures should be preceded by figuring out top soil, weathered and soft rock layers, shape of basement, fracture zones, geologic boundary and etC. from the seismic refraction data. It is very important to set up suitable field parameters, which are the configuration of profile and its length, spacings of geophones and sources and topographic conditions, for increasing field data Quality. Geophone spacing of 3 to 5m is reconunended in the land slope area of house land development site. In refraction tomography technique, the number of source points should be more than a Cluarter of available channel number of instrument and the subsurface structure interpretation can be decreased the artifact of inversion by topographic effect. Compared with core logging data, it is shown that the velocity range of the soil is less than 700m/s, weathered rock 700~1,200m/s, soft rock 1,200~1,800m/s on the velocity tomogram section. And the upper limit of P-wave velocity for rippability is estimated 1,200 to 1,800m/s in land slope area of gneiss.

  • PDF

The Analysis of Geothermal Gradient at Icheon Hot Spa Area (이천 온천원보호지구의 지온경사 해석)

  • Lee, Chol-Woo;Moon, Sang-Ho
    • The Journal of Engineering Geology
    • /
    • v.18 no.2
    • /
    • pp.185-190
    • /
    • 2008
  • Nine wells have been developed for uses of thermal waters at the Icheon hot spa area. Drilling depths of those hot spring wells range from 166 to 294 m and their piezometric heads are located at about 50 m below the surface. Using the differences between the surface and bottom temperatures within all boreholes, we can simply estimate geothermal gradient in this area. Thus, we obtained the highest, lowest and average gradient values as $64^{\circ}C/km$ from SB-2 well, $45^{\circ}C/km$ from SB-1 well and approximately $54.28^{\circ}C/km$, respectively. However, observing the MRD-2 well additionally drilled into the depth of 996 m, we found out that this study area has widely experienced the temperature disturbance due to thermal groundwater penetration through the fracture systems within the depth of 720 m. Unlikely this phenomenon, we can conclude that the groundwater flow below the depth of 720 m does not exist. Therefore, using only those temperature data below the 720 m depth, we can estimate reasonable geo-thermal gradient values as $33^{\circ}C/km$ in this study area. Pumping test shows that outflowing temperature is $36^{\circ}C$ corresponding to the temperature logging data at 720 m depth.