Abstract
Nine wells have been developed for uses of thermal waters at the Icheon hot spa area. Drilling depths of those hot spring wells range from 166 to 294 m and their piezometric heads are located at about 50 m below the surface. Using the differences between the surface and bottom temperatures within all boreholes, we can simply estimate geothermal gradient in this area. Thus, we obtained the highest, lowest and average gradient values as $64^{\circ}C/km$ from SB-2 well, $45^{\circ}C/km$ from SB-1 well and approximately $54.28^{\circ}C/km$, respectively. However, observing the MRD-2 well additionally drilled into the depth of 996 m, we found out that this study area has widely experienced the temperature disturbance due to thermal groundwater penetration through the fracture systems within the depth of 720 m. Unlikely this phenomenon, we can conclude that the groundwater flow below the depth of 720 m does not exist. Therefore, using only those temperature data below the 720 m depth, we can estimate reasonable geo-thermal gradient values as $33^{\circ}C/km$ in this study area. Pumping test shows that outflowing temperature is $36^{\circ}C$ corresponding to the temperature logging data at 720 m depth.
Keywords
Icheon hot spa area; geothermal gradient; bottom temperature; groundwater;
Citations & Related Records
연도 인용수 순위
  • Reference
1 김형찬, 이사로, 송무영, 2002, 남한지역의 암상 및 지질 시대별 지온경사율 관계 분석, 자원환경지질학회지, 제 35권, 제 2호, pp. 163-170
2 임정웅, 이철우, 배두종, 문상호, 이종철, 이승구, 성기성, 1998. 1, 이천(안흥)지구 온천공 영향평가 조사보고서, 98-1, No. 259, p. 253
3 Beck, A.E. and N. Balling, 1988, Determination of virgin rock temperatures: Handbook of terrestrial heatflow density determination: ed. by R. Haenel, Kluwer Academic Publishers, pp. 75-85
4 이춘기, 한욱, 이상우, 2000.9, 서울의 동북지역 지온측점 에서 기온에 따른 지온의 반응 양상, 지질학회지 제 36권, 제 3호, pp. 325-334
5 김형찬, 송무영, 1999, 지온경사 산출을 위한 효율적인 온도검층자료 이용방법 연구, 자원환경지질학회지, Vol. 32, No. 5, pp. 503-517
6 문상호, 이철우, 염병우, 김형찬, 성기성, 1999. 1, 이천(안흥)지구 온천자원평가조사 보고서, 99-1, No. 264, p. 110