• Title/Summary/Keyword: Korean Paper

Search Result 170,828, Processing Time 0.173 seconds

Accurate Quality Control Method of Bone Mineral Density Measurement -Focus on Dual Energy X-ray Absorptiometry- (골밀도 측정의 정확한 정도관리방법 -이중 에너지 방사선 흡수법을 중심으로-)

  • Kim, Ho-Sung;Dong, Kyung-Rae;Ryu, Young-Hwan
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.361-370
    • /
    • 2009
  • The image quality management of bone mineral density is the responsibility and duty of radiologists who carry out examinations. However, inaccurate conclusions due to lack of understanding and ignorance regarding the methodology of image quality management can be a fatal error to the patient. Therefore, objective of this paper is to understand proper image quality management and enumerate methods for examiners and patients, thereby ensuring the reliability of bone mineral density exams. The accuracy and precision of bone mineral density measurements must be at the highest level so that actual biological changes can be detected with even slight changes in bone mineral density. Accuracy and precision should be continuously preserved for image quality of machines. Those factors will contribute to ensure the reliability in bone mineral density exams. Proper equipment management or control methods are set with correcting equipment each morning and after image quality management, a phantom, recommended from the manufacturer, is used for ten to twenty-five measurements in search of a mean value with a permissible range of ${\pm}1.5%$ set as standard. There needs to be daily measurement inspections on the phantom or at least inspections three times a week in order to confirm the existence or nonexistence of changes in values in actual bone mineral density. in addition, bone mineral density measurements were evaluated and recorded following the rules of Shewhart control chart. This type of management has to be conducted for the installation and movement of equipment. For the management methods of inspectors, evaluation of the measurement precision was conducted by testing the reproducibility of the exact same figures without any real biological changes occurring during reinspection. Bone mineral density inspection was applied as the measurement method for patients either taking two measurements thirty times or three measurements fifteen times. An important point when taking measurements was after a measurement whether it was the second or third examination, it was required to descend from the table and then reascend. With a 95% confidence level, the precision error produced from the measurement bone mineral figures came to 2.77 times the minimum of the biological bone mineral density change. The value produced can be stated as the least significant change (LSC) and in the case the value is greater, it can be stated as a section of genuine biological change. From the initial inspection to equipment moving and shifter, management must be carried out and continued in order to achieve the effects. The enforcement of proper quality control of radiologists performing bone mineral density inspections which brings about the durability extensions of equipment and accurate results of calculations will help the assurance of reliable inspections.

  • PDF

The Development of On-Line Statistics Program for Radiation Oncology (방사선종양학과 On-line 통계처리프로그램의 개발)

  • Kim Yoon-Jong;Lee Dong-Hoon;Ji Young-Hoon;Lee Dong-Han;Jo Chul-Ku;Kim Mi-Sook;Ru Sung-Rul;Hong Seung-Hong
    • Radiation Oncology Journal
    • /
    • v.19 no.4
    • /
    • pp.369-380
    • /
    • 2001
  • Purpose : By developing on-line statistics program to record the information of radiation oncology to share the information with internet. It is possible to supply basic reference data for administrative plans to improve radiation oncology. Materials and methods : The information of radiation oncology statistics had been collected by paper forms about 52 hospitals in the past. Now, we can input the data by internet web browsers. The statistics program used windows NT 4.0 operation system, Internal Information Server 4.0 (IIS4.0) as a web server and the Microsoft Access MDB. We used Structured Query Language (SQL), Visual Basic, VBScript and JAVAScript to display the statistics according to years and hospitals. Results : This program shows present conditions about man power, research, therapy machines, technics, brachytherapy, clinic statistics, radiation safety management, institution, quality assurance and radioisotopes in radiation oncology department. The database consists of 38 inputs and 6 outputs windows. Statistical output windows can be increased continuously according to user's need. Conclusion : We have developed statistics program to process all of the data in department of radiation oncology for reference information. Users easily could input the data by internet web browsers and share the information.

  • PDF

The Extended Site Assessment Procedure Based on Knowledge of Biodegradability to Evaluate the Applicability of Intrinsic Remediation (자연내재복원기술(Intrinsic Remediation)적용을 위한 오염지역 평가과정 개발)

  • ;Robert M. Cowan
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.3
    • /
    • pp.3-21
    • /
    • 1997
  • The remediation of contamiated sites using currently available remediation technologies requires long term treatment and huge costs, and it is uncertain to achieve the remediation goal to drop contamination level to either back-ground or health-based standards by using such technologies. Intrinsic remediation technology is the remediation technology that relies on the mechanisms of natural attenuation for the containment and elimination of contaminants in subsurface environments. Initial costs for the intrinsic remediation may be higher than conventional treatment technologies because the most comprehensive site assessment for intrinsic remediation is required. Total remediation cost, however may be the lowest among the presently employed technologies. The applicability of intrinsic remediation in the contaminated sites should be theroughly investigated to achieve the remedial goal of the technology. This paper provides the frame of the extended site assessment procedure based on knowledge of biodegradability to evaluate the applicability of intrinsic remediation. This site assessment procedure is composed of 5 steps such as preliminary site screening, assessment of the current knowledge of biodegradability, selecting the appropriate approach, analyzing the contaminant fate and transport and planning the monitoring schedule. In the step 1, followings are to be decided 1) whether to go on the the detailed assessment or not based on the rules of thumb concerning the biodegradability of organic compounds, 2) which protocol document is selected to follow for detailed site assessment according to the site characteristics, contaminants and the relative distance between the contamination and potential receptors. In the step 2, the database for biodegradability are searched and evaluated. In the step 3, the appropriate biodegradability pathways for the contaminated site is selected. In the step 4, the fate and transport of the contaminants at the site are analyzed through modeling. In the step 5, the monitoring schedule is planned according to the result of the modeling. Through this procedure, users may able to have the rational and systematic informations for the application of intrinsic remediation. Also the collected data and informations can be used as the basic to re-select the other remediation technology if it reaches a conclusion not to applicate intrinsic remediation technology at the site from the site assessment procedure.

  • PDF

STUDIES ON THE CYSTINE COMPONENT IN THE SERICULTURAL PROTEINS OF BOMBYX MORI L. (가잠사단백질의 각과정에서의 Cystine 성분에 대한 연구)

  • Choe, Byong-Hee
    • Journal of Sericultural and Entomological Science
    • /
    • v.2
    • /
    • pp.1-31
    • /
    • 1962
  • The purpose of this treatise is to prove the presence of cystine in silk fiber through wide sampling throughout all the sericultural processes of Bombyx mori.; also to show that disulfide cross linkages exist in the silk fiber. The conclusions reached were as follows: 1. Crystalline cystine was obtained from silk fibroin using Folin's Method. 2. Analytical data showing the cystine content of silk fiber and its related materials were obtained using Sullvan's Method as follows: Material Percent Cystine A. Mulberry leaf protein 0.175 B. Silkworm egg 0.33 C. Silkworm Body, matured, fat extracted, without silk gland 0.41 D. Silk gland, matured 1.23 E. Silkworm feces none F. Silkworm pupa, fat extracted 0.30 G. Silkworm moth, fat extracted 0.60 H. Raw Silk 0.22 I. Fibroin 0.175 J. Sericin 0.30 3. The presence of cystine in the silkworm was substantiated the existence of 0.175 % methionine in mulberry leaves and 0.12% methionine in the silk gland. 4. Part of the sulfhydryl compounds in the silk gland is believed to transfer to serine and methionine, with the former being secreted into the liquid silk finally as silk fiber and the latter used for nutritive purposes in the growing of silk gland tissue. 5. The cystine content is variable by mulberry species, silkworm species, sex, breeding process, and other culturing environments. 6. Hybrid silkworms require more nutritive amino acids for effective growth than the original parents, and secrete less of them as silk fiber. 7. From such an observation, the amino acid composition of silk fiber is believed to be fairly flexible. Cystine if included in the amorphous part of the fiber, especially in sericin. 8. The result from enriching the silkworm diet with pure cystine or wool cystine did not result in any advantage, therefore it is believed that the natural cystine and methionine contents in the mulberry leafaregoodenoughforsilkwormnutrition. 9. The disulfide cross linkage in silk fiber was verified by using the Harris Method. Contraction took place following the treatment of the fiber with various salts and acids. Comparisons were made with wool fiber. 10. During these experiments, the fibrious structure of silk fiber and the net-globular liquid form were photographed microscopically. It is believed that the globules of liquid silk are net-formed by the inter attraction of the OH ion of the globular peptide and the H ion of water as shown by the hair cracking behavior of the film. The net-globular protein precipitation from the mulberry protein solution showed that mulberry is a proper diet for the formation of fibrous protein in the silk fiber. 11. The significance of the presence of cystine in silk fiber as emphasized in this paper should result in modification of the general conception that cystine is absent from this fiber. NOTICE: A part of this treatise was presented at the annual Korea Sericultural Society meeting held in 1961.

  • PDF

Partial Anomalous Pulmonary Venous Connection to the Superior Vena Cava

  • Lee, Sub;Kim, Han-Woong;Kang, Hyoung-Seok;Bae, Chi-Hoon;Jheon, Sang-Hoon;Kwon, Oh-Choon;Ahn, Wook-Su
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.672-679
    • /
    • 2001
  • Background: Surgical correction of partial anomalous pulmonary venous connection to the superior vena cava has been associated with postoperative venous obstruction and sinus node dysfunction. In this paper we describe our current approach and its short-term results. Material and Method: Between April 1999 and January 2000, 5 consecutive patients, ranging from 2 months to 66 years old, underwent corrective operation for partial anomalous pulmonary venous connection to the superior vena cava at Sejong General Hospital and Daegu Catholic University Medical Center. Surgical correction involved diversion of the pulmonary venous drainage to the left atrium using a right atrial flap(2 patients) or prosthetic patch(3 patients) with division of the superior vena cava superior to the restore site of the pulmonary veins and reimplantation on the right atrial appendage to restore systemic venous drainage. Result: All patients were discharged between postoperative day 9 and 15 without complications. One Russian boy returned to his country, therefore, he was lost to follow-up after discharge. Remaining 4 patients were asymptomatic and in normal regular sinus rhythm at a mean follow-up of 17.75$\pm$4.27 months. Follow-up echocardiographic study (range, 12 to 24 months) revealed no incidence of narrowing of the venous pathways or of residual shunt. Conclusion: Our current approach is relatively simple and reproducible in achieving unobstructive pulmonay venous and SVC pathways. By avoiding incision across the cavoatrial junction, surgical injury to the sinus node and its artery may be minimized. The presented surgical technique can be safely and effectively applied to the selected patients.

  • PDF

When Robots Meet the Elderly: The Contexts of Interaction and the Role of Mediators (노인과 로봇은 어떻게 만나는가: 상호작용의 조건과 매개자의 역할)

  • Shin, Heesun;Jeon, Chihyung
    • Journal of Science and Technology Studies
    • /
    • v.18 no.2
    • /
    • pp.135-179
    • /
    • 2018
  • How do robots interact with the elderly? In this paper, we analyze the contexts of interaction between robots and the elderly and the role of mediators in initiating, facilitating, and maintaining the interaction. We do not attempt to evaluate the robot's performance or measure the impact of robots on the elderly. Instead, we focus on the circumstances and contexts within which a robot is situated as it interacts with the elderly. Our premise is that the success of human-robot interaction does not depend solely on the robot's technical capability, but also on the pre-arranged settings and local contingencies at the site of interaction. We select three television shows that feature robots for the elderly and one "dementia-prevention" robot in a regional healthcare center as our sites for observing robot-elderly interaction: "Grandma's Robot"(tvN), "Co-existence Experiment''(JTBC), "Future Diary"(MBC), and the Silbot class in Suwon. By analyzing verbal and non-verbal interactions between the elderly and the robots in these programs, we point out that in most cases the robots and the elderly do not meet one-to-one; the interaction is usually mediated by an actor who is not an old person. These mediators are not temporary or secondary components in the robot-elderly interaction; they play a key role in the relationship by arranging the first meeting, triggering initial interactions, and carefully observing unfolding interactions. At critical moments, the mediators prevent the interaction from falling apart by intervening verbally or physically. Based on our observation of the robot-elderly interaction, we argue that we can better understand and evaluate the human-robot interaction in general by paying attention to the existence and role of the mediators. We suggest that researchers in human-robot interaction should expand their analytical focus from one-to-one interactions between humans and robots to human-robot-human interactions in diverse real-world situations.

A Study on the Continuing Education of Dental Technicians (치과기공사의 보수교육에 관한 연구(I) -보수교육 실태와 인식을 중심으로 -)

  • Moon, Je-Hyuk
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.179-198
    • /
    • 2000
  • Since dental prosthesis is made possible only when dental technicians give themselves to the study of knowledge and the acquisition of updated skills, continuing education is of great importance in that it makes up for the efforts of dental technicians. Accordingly, continuing education relates to a system designed to contribute to the enhancement of the talents of dental technicians and the dental health of the nation. Specialized knowledge and information may work as the best weapon to preserve their jbs. This is true of this modern society where no one can expecth to survive without acquiring knowledge and information constantly for work is getting more classified and more divirsifide. This paper is dedicated to take a look at the current condition of the continuing education of dental technicians and to come up with measure to make general evaluation and to improve continuing education. This research resorts to 609 questionnaires among 6433 copies save unfaithfully responded 34 copos with 6.431 dental technicians as the subjects enrolled in the Dental technician Association. The collected questionnaires consist of 365 dental technicians living in Seoul and of 244 ones, Which account for 11.8 percent of dental technicians enrolled in the association. Because dental technicians live more in local areas than Seoul, the generalization of this survey leaves something to be desired. I have come up with the following findings. 1. 6,431 dental technicians, or 36.3 percent of an total of 14,956 licensed dental technicians, were admitted as numbers of the Dental Tachnician Association as of October 31, 1999. In the '98 continuing education. 4,141 dental technicians among 4,711 dental technicians got relevant training, and in the '99 continuing education, 4,075 technicians, or 75.9 percent of 5,365 technicians got relevant training while 1,290 technicians or 24.2 percent, fail to get relevant training. 2. The survey has it that 38.1 percent of dental technicians are ignorant of the laws on continuing education, and that technicians staying in local communities(146 persons, or 61.6%) take more part in education than those living in the capital of Korea(159 persons, or 146%), and that the older they are, the more money they earn, the more carrer they have, the higher position they hold, the more part they take in education 3. According to the survey, those who have the experience of getting training more than three times account for 52 persons(16.8%) in Seoul and 47 persons(22.4%) in local districts(p<0.01). In terms of sanctions in relation to continuing education, 26 dental technicians(4.6%) say that they have ever gotten sanctions, and 533 dental technicians(95.4%) say that they haven't. And those who were absent from continuing education(72 technicians : 13.51%) didn't get any sanction. 4. In terms of the degree of understanding continuing education, local technicians(46.8% : 110 persons) have a higher understanding of continuing education than their countparts staying in Seoul(36.0% : 130). Continuing education is not the ultimate goal itself. It should be changed to motivate those who get education to be willing to take part in contunuing education, and to help dental technicians in a practical and specific way. And the branch societies should be developde to engage in more specialized and classified expert fields. Of course, the curriculum should be so selected that the conceptions of dental technicians may be reflected to the maximum extent, and the ultimate effores should be made to effect diversity in the ways of educational methods and to perfect the preparation of continuing education on the part of instructors. Regulations should be established in relation to continuing education with a veiew to enhancing the participation of continuing education and its effectiveness. The supervision of the Ministry of Health and Welfare is of great importance in this context. The regulation of continuing education is not administrative regulation, but the expression of national will to guarantee the medical service of the nation at highest level. Therefore, it is necessary that the Ministry of Health and Welfare should change their understanding of the needs for the continuing education of dental experts, and that the expertise of government employees in charge of continuing education should be expanded. It goes without saying that the government should suppory continuing education in a financial way so as to supply the person in charge of public welfare and control the quality of national medicine.

  • PDF

Gadoteridol's Signal Change according to TR, TE Parameters in T1 Image (T1영상에서 TR, TE 매개변수에 따른 Gadoteridol의 신호강도 변화)

  • Jeong, Hyun Keun;Jeong, Hyun Do;Nam, Ki Chang;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.9
    • /
    • pp.117-124
    • /
    • 2015
  • In this paper, we introduce how to control TR, TE physical MR parameters for managing $H_1$ spin's SI(Signal Intensity) which is combined with gadolinium following administration MR agent in T1 effect for diagnostic usefulness. we used MRI phantom made with 0.5 mol Gadoteridol. This phantom was scanned by FSE sequence with different TR, TE parameters. In this study, to make T1 effect, TR was 200, 250, 300, 350, 400, 450, 500, 550, 600 msec. In addition to, TE was 6.2, 12.4, 18.6, 21.6 msec. The results were as follows ; Each RSP(Reaction Starting Point) was 100, 50, 40, 30 mmol in TE 6.2, 12.4, 18.6, 21.6 msec being irrelevant to TR. In MPSI(Max Peak Signal Intensity), 4 mmol was showed in TR 200 msec while peak signal was decreased to low concentration mol in TR 250-600 msec. In terms of RA(Reaction Area), the highest SI was TE 6.2 msec in TR 200-600msec. According to the study, we are able to recognize it is possible to control enhance rates by managing TR and TE of MR parameters; moreover, we expect that enhanced T1 image in MR clinical field can be performed in a practical way with this quantitative data.

Low-Power CMOS On-Chip Voltage Reference Circuits (저전력 CMOS On-Chip 기준전압 발생회로)

  • Kwon, Duck-Ki;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of IKEEE
    • /
    • v.4 no.2 s.7
    • /
    • pp.181-191
    • /
    • 2000
  • In this paper, two schemes of generating reference voltages using enhancement-mode MOS transistors and resistors are proposed. The first one is a voltage-mode scheme where the temperature compensation is made by summing a voltage component proportional to a threshold voltage and a voltage component proportional to a thermal voltage. In the second one, that is a current-mode scheme, the temperature compensation is made by summing a current component proportional to a threshold voltage and a current component proportional to a thermal voltage. The designed circuits have been simulated using a $0.65{\mu}m$ n-well CMOS process parameters. The voltage-mode circuit has a temperature coefficient less than $48.0ppm/^{\circ}C$ and a power-supply(VDD) coefficient less than 0.21%/V for a temperature range of $-30^{\circ}C{\sim}130^{\circ}C$ and a VDD range of $3V{\sim}12V$. The current-mode circuit has a temperature coefficient less than $38.2ppm/^{\circ}C$ and a VDD coefficient less than 0.8%/V for $-30^{\circ}C{\sim}130^{\circ}C\;and\; 4V{\sim}12V$. The power consumption of the voltage-mode and current-mode circuits are $27{\mu}W\;and\;65{\mu}W$ respectively for 5V and $30^{\circ}C$. Measurement results show that the voltage-mode reference circuit has a VDD coefficient less than 0.63%/V for $30^{\circ}C{\sim}100^{\circ}C$ and has a temperature coefficient less than $490ppm/^{\circ}C\;for\;3V{\sim}6V$. The proposed reference circuits are simple and thus easy to design. The proposed current-mode reference circuit can be designed to generate a wide range of reference voltages.

  • PDF

A Study On Design of ZigBee Chip Communication Module for Remote Radiation Measurement (원격 방사선 측정을 위한 ZigBee 원칩형 통신 모듈 설계에 대한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.552-558
    • /
    • 2014
  • This paper suggests how to design a ZigBee-chip-based communication module to remotely measure radiation level. The suggested communication module consists of two control processors for the chip as generally required to configure a ZigBee system, and one chip module to configure a ZigBee RF device. The ZigBee-chip-based communication module for remote radiation measurement consists of a wireless communication controller; sensor and high-voltage generator; charger and power supply circuit; wired communication part; and RF circuit and antenna. The wireless communication controller is to control wireless communication for ZigBee and to measure radiation level remotely. The sensor and high-voltage generator generates 500 V in two consecutive series to amplify and filter pulses of radiation detected by G-M Tube. The charger and power supply circuit part is to charge lithium-ion battery and supply power to one-chip processors. The wired communication part serves as a RS-485/422 interface to enable USB interface and wired remote communication for interfacing with PC and debugging. RF circuit and antenna applies an RLC passive component for chip antenna to configure BALUN and antenna impedance matching circuit, allowing wireless communication. After configuring the ZigBee-chip-based communication module, tests were conducted to measure radiation level remotely: data were successfully transmitted in 10-meter and 100-meter distances, measuring radiation level in a remote condition. The communication module allows an environment where radiation level can be remotely measured in an economically beneficial way as it not only consumes less electricity but also costs less. By securing linearity of a radiation measuring device and by minimizing the device itself, it is possible to set up an environment where radiation can be measured in a reliable manner, and radiation level is monitored real-time.