• Title/Summary/Keyword: K-mismatch

Search Result 896, Processing Time 0.032 seconds

Prediction of Steady-State Stresses within Heat Affected Zone Due to Creep Mismatch in Welded Straight Pipes (직관 용접부의 크리프 특성 불균일에 따른 열영향부 정상상태 응력 예측)

  • Han, Jae-Jun;Kim, Sang-Hyun;Chung, Jin-Taek;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.3
    • /
    • pp.405-412
    • /
    • 2013
  • This paper reports the steady-state stresses within the heat affected zone (HAZ) of a welded straight pipe subject to creep. The creep constants and exponent are varied systematically to see the effect of various mismatches in creep properties on the steady-state creep stresses, via detailed two-dimensional finite element (FE) creep analyses. The weldments consist of the base metal and weld metal with the HAZ, which are characterized using the idealized power creep laws with the same creep exponent. The internal pressure and axial loading are considered to see the effect of the loading mode. To quantify the creep stresses, a creep mismatch factor is introduced as a function of the creep constants and exponent. It is concluded that the ratio of the section-averaged stresses for a mismatched case to those for an evenmatched case are linearly dependent on the mismatch factor. The results are compared with the FE results, including the Type IV region, as well as the R5 procedure.

Mismatch Limit Load Analyses for V-groove Welded Pipe with Through-wall Circumferential Defect in Centre of Weld (원주방향 관통균열이 용접부 중앙에 존재하는 V-그루브 맞대기 용접배관의 한계하중 해석)

  • Kim, Sang-Hyun;Han, Jae-Jun;Chung, Jin-Taek;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.11
    • /
    • pp.1379-1386
    • /
    • 2013
  • The present work reports the mismatch limit loads for a V-groove welded pipe for a circumferential crack using finite element (FE) analyses. To integrate the effect of groove angles on mismatch limit loads, one geometry-related slenderness parameter was modified by relevant geometric parameters including the groove angle, crack depth, and root opening based on plastic deformation patterns in the theory of plasticity. Circumferential through-wall cracks are located at the centre of the weldments with two different groove angles ($45^{\circ}$, $90^{\circ}$). With regard to the loading conditions, axial (longitudinal) tension and bending are applied for all cases. For the parent and weld metal, elastic-perfectly plastic materials are considered to simulate and analyze under- and over-matching conditions in plasticity. The overall results from the proposed solutions are found to be similar to the FE results.

Diffusion-Enhanced Modified Hemodialyzer

  • Lee, Kyung-Soo;Lee, Sa-Ram;Mun, Cho-Hae;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.455-460
    • /
    • 2007
  • Flow mismatch between blood and dialysate is invariably encountered during conventional hemodialysis, and this deteriorates diffusive mass transfer. A modification of a conventional dialyzer was conceived to prevent this mismatch. The modified dialyzer includes two independent blood flow regions (central and peripheral regions), which were achieved by redesigning the dialyzer cap. Resultantly, the blood stream was divided into two concentric dialyzer regions. Solutes clearances obtained using the modified dialyzers were compared with those of conventional dialyzers. Solutes clearances by conventional dialyzers were uniform, but solutes clearances by modified dialyzers were found to be dependent on the simulated blood split into dialyzer central and peripheral regions. Maximal clearances using the modified dialyzer were improved by up to approximately 7.6% for urea and 7.3% for creatinine, as compared with those of conventional dialyzers. More optimizations are required for clinical applications, but the finding that blood flowrates through central and peripheral fiber bundles can be easily regulated is encouraging.

Comparison of Population Genetic Structure of Two Seashore-Dwelling Animal Species, Periwinkle Littorina brevicula and Acorn Barnacle Fistulobalanus albicostatus from Korea

  • Kim, Yuhyun;Lee, Jeounghee;Kim, Hanna;Jung, Jongwoo
    • Animal Systematics, Evolution and Diversity
    • /
    • v.32 no.2
    • /
    • pp.105-111
    • /
    • 2016
  • The genetic structure of marine animals that inhabit the seashore is affected by numerous factors. Of these, gene flow and natural selection during recruitment have strong influences on the genetic structure of seashore-dwelling species that have larval periods. Relative contributions of these two factors to the genetic structure of marine species would be determined mainly by the duration of larval stage. The relationship between larval period and genetic structure of population has been rarely studied in Korea. In this study, genetic variations of cytochrome oxidase subunit I (COI) were analyzed in two dominant species on rocky shore habitats in the Korean peninsula: periwinkle Littorina brevicula and acorn barnacle Fistulobalanus albicostatus. Both species are not strongly structured and may have experienced recent population expansion. Unlike periwinkle, however, barnacle populations have considerable genetic variation, and show a bimodal pattern of mismatch distribution. These results suggest that barnacle populations are more affected by local adaptation rather than gene flow via larval migration. The bimodal patterns of barnacle populations observed in mismatch distribution plots imply that they may have experienced secondary contact. Further studies on seashore-dwelling species are expected to be useful in understanding the evolution of the coastal ecosystem around Korean waters.

A 100~110 GHz LNA and A Coupler Using Standard 65 n CMOS Process (상용 65 n CMOS 공정을 이용한 100~110 GHz 저잡음 증폭기와 커플러)

  • Kim, Jihoon;Park, Hongjong;Kwon, Youngwoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.3
    • /
    • pp.278-285
    • /
    • 2013
  • In this paper, a 100~110 GHz LNA and A coupler using standard 65 n CMOS process is presented. The LNA consists of three common source FET stages. A few layout types are considered to get high gain characteristic of unit common source cell. Also, optimized performance to achieve low noise characteristic and enough gain. Coupler is composed of broadside coupler using multimetal in CMOS fabrication. In the coupler, the metal strip to meet density rule is used, and the coupler is designed with consideration of the metal strip to function properly. Gain of fabricated LNA is 5.64 dB at 100 GHz and 6.39 dB at 110 GHz. Bandwidth is over 10 % and noise figure is 11.66 dB at 100 GHz. Fabricated coupler has shown insertion loss of 2~3 dB at 100~110 GHz band. Magnitude mismatch of coupler is below 1 dB and phase mismatch of coupler is below $5^{\circ}$.

Investigation on the Effect of Strength Mismatch on Residual Stresses in Welds with Different Strength Used in Buried Natural Gas Pipeline (매설 가스 배관 이종금속 용접부의 강도 불일치가 잔류응력에 미치는 영향 고찰)

  • Kim, Jong-Sung;Kim, Woo-Sik;Baek, Jong-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.4
    • /
    • pp.413-421
    • /
    • 2010
  • In this study, residual-stress distributions in welds with different strength used in natural gas pipelines are calculated by using finite-element analysis and simulating a realistic welding process. The temperature and residual-stress analysis results are compared with the real fusion profile and the application results of the Fitness-For-Service assessment code, API 579 in order to validate the finite-element analysis model and procedure. Parametric study is performed to assess the effect of welding and material variables such as mechanical strength mismatch, the strength of weld metal, reinforcement, and heat input on the residual stress distributions. Finally, on the basis of the parametric study results, the effects of these variables on residual stress distributions are investigated. In particular, the strength mismatch between base metals has an insignificant effect on residual-stress distributions.

Assessment of Diffusion-Weighted Imaging-FLAIR Mismatch: Comparison between Conventional FLAIR versus Shorter-Repetition-Time FLAIR at 3T

  • Goh, Byeong Ho;Kim, Eung Yeop
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.2
    • /
    • pp.88-94
    • /
    • 2016
  • Purpose: Fluid-attenuated inversion recovery (FLAIR) imaging can be obtained faster with shorter repletion time (TR), but it gets noisier. We hypothesized that shorter-TR FLAIR obtained at 3 tesla (3T) with a 32-channel coil may be comparable to conventional FLAIR. The aim of this study was to compare the diagnostic value between conventional FLAIR (TR = 9000 ms, FLAIR9000) and shorter-TR FLAIR (TR = 6000 ms, FLAIR6000) at 3T in terms of diffusion-weighted imaging-FLAIR mismatch. Materials and Methods: We recruited 184 patients with acute ischemic stroke (28 patients < 4.5 hours) who had undergone 5-mm diffusion-weighted imaging (DWI) and two successive 5-mm FLAIR images (no gap; in-plane resolution, $0.9{\times}0.9mm$) at 3T with a 32-channel coil. The acquisition times for FLAIR9000 and FLAIR6000 were 108 seconds (generalized autocalibrating partially parallel acquisitions [GRAPPA] = 2) and 60 seconds (GRAPPA = 3), respectively. Two radiologists independently assessed the paired imaging sets (DWI-FLAIR9000 and DWI-FLAIR6000) for the presence of matched hyperintense lesions on each FLAIR imaging. The signal intensity ratios (area of DWI lesion to contralateral normal-appearing region) on both FLAIR imaging sets were compared. Results: DWI-FLAIR9000 mismatch was present in 39 of 184 (21.2%) patients, which was perfectly the same on FLAIR6000. Three of 145 patients (2%) with DWI-matched lesions on FLAIR9000 had discrepancy on FLAIR6000, showing no significant difference (P > 0.05). Interobserver agreement was excellent for both DWI-FLAIR9000 and DWI-FLAIR6000 (k = 0.904 and 0.883, respectively). Between the two FLAIR imaging sets, there was no significant difference of signal intensity ratio (mean, standard deviation; $1.25{\pm}0.20$; $1.24{\pm}0.20$, respectively) (P > 0.05). Conclusion: For the determination of mismatch or match between DWI and FLAIR imaging, there is no significant difference between FLAIR9000 and FLAIR6000 at 3T with a 32-channel coil.

A Charge Pump with Matched Delay Paths for Reduced Timing Mismatch (타이밍 부정합 감소를 위해 정합된 지연경로를 갖는 전하 펌프)

  • Heo, Joo-Il;Heo, Jung;Jeong, Hang-Geun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.5
    • /
    • pp.37-42
    • /
    • 2012
  • In this paper, a new charge pump is proposed to reduce the timing mismatch in the conventional current-steering charge pumps. Conventional current-steering charge pumps used NMOS input stages both for UP and DOWN signals, which resulted in different numbers of stage for UP and DOWN delay paths. The proposed charge pump has equalized the numbers of stages for UP and DOWN signals by using a PMOS stage for the DOWN signal. The simulation results show that the conventional current-steering charge pump has 14ns and 6ns for optimized timing mismatches between UP and DOWN signals for turn-on and turn-off, respectively. On the other hand, the proposed charge pump has improved timing mismatches of 6ns and 5ns for turn-on and turn-off, respectively. As a result, the reference spurs are reduced from -26dBc to -39dBc for the proposed charge pump. The proposed charge pump was designed by using $0.18{\mu}m$ CMOS technology. The measurement results show that the maximum variation of the charging and discharging current over the charge pump output voltage range of 0.3~1.5V is approximately 1.5%.

A Charge Pump Circuit in a Phase Locked Loop for a CMOS X-Ray Detector (CMOS X-Ray 검출기를 위한 위상 고정 루프의 전하 펌프 회로)

  • Hwang, Jun-Sub;Lee, Yong-Man;Cheon, Ji-Min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.5
    • /
    • pp.359-369
    • /
    • 2020
  • In this paper, we proposed a charge pump (CP) circuit that has a wide operating range while reducing the current mismatch for the PLL that generates the main clock of the CMOS X-Ray detector. The operating range and current mismatch of the CP circuit are determined by the characteristics of the current source circuit for the CP circuit. The proposed CP circuit is implemented with a wide operating current mirror bias circuit to secure a wide operating range and a cascode structure with a large output resistance to reduce current mismatch. The proposed wide operating range cascode CP circuit was fabricated as a chip using a 350nm CMOS process, and current matching characteristics were measured using a source measurement unit. At this time, the power supply voltage was 3.3 V and the CP circuit current ICP = 100 ㎂. The operating range of the proposed CP circuit is △VO_Swing=2.7V, and the maximum current mismatch is 5.15 % and the maximum current deviation is 2.64 %. The proposed CP circuit has low current mismatch characteristics and can cope with a wide frequency range, so it can be applied to systems requiring various clock speed.

The Implementation of the Compensation Algorithm of Time Delay for Microwave Polar Transmitters (마이크로파 폴라 송신기의 시간지연 보상 알고리즘 구현)

  • Kim, Min-Soo;Lee, Kun-Joon;Rhee, Young-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.9
    • /
    • pp.790-797
    • /
    • 2015
  • In this paper, We made the microwave polar transmitter based on the software to analyze the synchronization status between the phase signal and the amplitude signal of polar transmitter, and analyzed the result. In order to solve the time delay mismatch problem, we applied simplified compensation algorithm and compared the synchronization status between the two paths before and after compensation. Before compensation, the value of time delay mismatch was the maximum of 97 nsec at 9.3 GHz with the occupied bandwidth of 12 MHz, but after applying the compensation algorithm, the signals between the two paths were synchronized, and we identified the occupied bandwidth could recover to the previous 3.7 MHz.