• Title/Summary/Keyword: Integrity test

Search Result 909, Processing Time 0.03 seconds

An Effective Multiple Transition Pattern Generation Method for Signal Integrity Test on Interconnections (Signal Integrity 연결선 테스트용 다중천이 패턴 생성방안)

  • Kim, Yong-Joon;Kang, Sung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.10
    • /
    • pp.39-44
    • /
    • 2008
  • Scan architecture is very effective design-for-testability technique that is widely used for high testability, however, it requires so much test time due to test vector shifting time. In this paper, an efficient scan test method is presented that is based on the Illinois scan architecture. The proposed method maximizes the common input effect via a scan chain selection scheme. Experimental results show the proposed method requires very short test time and small data volume by increasing the efficiency of common input effect.

Improved Application Test Data Range Selection Method in a Non-Personal Information Identification Environment (개인정보 비식별 환경에서의 개선된 응용프로그램 테스트 데이터 범위 선정 방법)

  • Baek, Song-yi;Lee, Kyung-ho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.30 no.5
    • /
    • pp.823-834
    • /
    • 2020
  • In the past, when the personal information leakage incident of the three card companies, the computer program development was followed by the same strict electronic financial supervision regulations as the operating environment. However, when developing a computerized program, the application data is being verified with the integrity of the test data being compromised because the identification of the scope of conversion of the test data associated with the application is unclear. Therefore, in this paper, we proved by presenting a process and algorithm for selecting a range of sufficient test data conversion targets associated with a specific application.

Structural Joint Integrity Monitoring of Steel Frame Structures Using Impulse Responses (충격응답을 이용한 철골 구조물 접합부의 구조건전성 모니터링)

  • Yi, Jin-Hak;Lee, Kwang-Soo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.145-150
    • /
    • 2008
  • This study proposes an improved AR-model based structural joint integrity monitoring method and a new damage sensitive feature using RMS values of impulse responses. The proposed methods were applied for joint integrity monitoring of a model scale 2-bay and 4-story steel frame structure and it was found that the AR coefficients could be more consistently estimated by adopting the band-pass filter and cross-correlation function to the raw acceleration signals and the joint damages could be successfully monitored by the proposed methods.

  • PDF

Fatigue life evaluation of Electric Car Bogie Frame (전동차 대차 프레임의 피로수명 평가)

  • Seo, Jung-Won;Kwon, Sung-Tae;Kim, Jeong-Guk
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1517-1522
    • /
    • 2007
  • Bogie frame of the electric car is an important structural member for the support of vehicle loading. In general, more than 25 years' durability is necessary. A lot of study has been carried out for the prediction of the structural integrity of the bogie frame in experimental and theoretical domains. The objective of this paper is to estimate the structural integrity of the bogie frame of an electric car, which is under the running test. F.E. analysis of bogie frame was performed to find locations for attaching strain gage and to estimate static stress. Dynamic stress were measured by using strain gage in order to evaluate the structural integrity of the bogie frame.

  • PDF

Ultrasonic Testing of Voids inside Mortar for Structural Integrity Evaluation (구조물 건전도 평가를 위한 모르타르 내 공극 초음파 탐상)

  • Cho, Youn-jin;Rhim, Hong-Chul;Kim, Dae-You
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.91-92
    • /
    • 2016
  • Structural integrity of reinforced concrete structures including nuclear power plants needs to be evaluated on a regular basis. Deterioration inside the concrete structures can be represented by voids. In this study, the varied volume fraction of voids inside mortar specimens was studied as a parameter using ultrasonic testing equipments. Both direct and indirect measurement methods were employed. The results show that there is a clear distinction between the specimens with different void volume fractions.

  • PDF

Comparison of vessel failure probabilities during PTS for Korean nuclear power plants

  • Jhung, M.J.;Choi, Y.H.;Chang, Y.S.
    • Structural Engineering and Mechanics
    • /
    • v.37 no.3
    • /
    • pp.257-265
    • /
    • 2011
  • Plant-specific analyses of 5 types of domestic reactors in Korea are performed to assure the structural integrity of the reactor pressure vessel (RPV) during transients which are expected to initiate pressurized thermal shock (PTS) events. The failure probability of the RPV due to PTS is obtained by performing probabilistic fracture mechanics analysis. The through-wall cracking frequency is calculated and compared to the acceptance criterion. Considering the fluence at the end of life expected by surveillance test, the sufficient safety margin is expected for the structural integrity of all reactor pressure vessels except for the oldest one during the pressurized thermal shock events. If the flaw with aspect ratio of 1/12 is considered to eliminate the conservatism, the acceptance criteria is not exceeded for all plants until the fluence level of $8{\times}10^{19}\;n/cm^2$, generating sufficient margin beyond the design life.

Experimental Characterization and Signal Integrity Verification of Interconnect Lines with Inter-layer Vias

  • Kim, Hye-Won;Kim, Dong-Chul;Eo, Yung-Seon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.11 no.1
    • /
    • pp.15-22
    • /
    • 2011
  • Interconnect lines with inter-layer vias are experimentally characterized by using high-frequency S-parameter measurements. Test patterns are designed and fabricated using a package process. Then they are measured using Vector Network Analyzer (VNA) up to 25 GHz. Modeling a via as a circuit, its model parameters are determined. It is shown that the circuit model has excellent agreement with the measured S-parameters. The signal integrity of the lines with inter-layer vias is evaluated by using the developed circuit model. Thereby, it is shown that via may have a substantially deteriorative effect on the signal integrity of high-speed integrated circuits.

A Study on the Verification of Integrity of Message Structure in Naval Combat Management System

  • Jung, Yong-Gyu
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.12
    • /
    • pp.209-217
    • /
    • 2022
  • Naval CMS(Combat Management System) is linked to various sensors and weapon equipment and use DDS(Data Distribution Service) for efficient data communication between ICU(Interface Control Unit) Node and IPN(Information Processing Node). In order to use DDS, software in the system communicates in an PUB/SUB(Publication/Subscribe) based on DDS topic. If the DDS messages structure in this PUB/SUB method does not match, problems such as incorrect command processing and wrong information delivery occur in sending and receiving application software. To improve this, this paper proposes a DDS message structure integrity verification method. To improve this, this paper proposes a DDS message structure integrity verification method using a hash tree. To verify the applicability of the proposed method to Naval CMS, the message integrity verification rate of the proposed method was measured, and the integrity verification method was applied to CMS and the initialization time of the existing combat management system was compared and the hash tree generation time of the message structures was measured to understand the effect on the operation and development process of CMS. Through this test, It was confirmed that the message structure verification method for system stability proposed in this paper can be applied to the Naval CMS.

Structural Integrity of Small Wind Turbine Composite Blade Using Structural Test and Finite Element Analysis (구조시험 및 유한요소해석을 통한 소형풍력발전용 복합재 블레이드의 구조 안전성 평가)

  • Jang, Yun-Jung;Lee, Jang-Ho;Kang, Ki-Weon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.9
    • /
    • pp.1087-1094
    • /
    • 2012
  • This study deals with structural analysis and testing under loading conditions calculated by computational fluid dynamics for a small composite blade that is utilized in a dual rotor wind turbine system. First, the aerodynamic forces were analyzed at the rated and cutout wind speed to identify the bending moment distribution along the blade length in previous research. Then, full-scale structural tests were conducted according to IEC 61400-2 to evaluate the structural integrity of the composite blade. These results were compared with finite element analysis to identify the accuracy of the structural analysis. Based on these results, it was revealed that the existing blade has a very high safety margin. Then, the layup of the composite blade was redesigned and analyzed using finite element analysis to achieve structural integrity and economic efficiency.

Development of Full-scale Airframe Durability Test Technique (항공기 전기체 내구성시험 기법 개발)

  • Shul, Chang-Won;Yang, Myung-Seog;Lee, Kee-Bhum;Jung, Jae-Kwon;Kang, Hui-Won;Lee, Kyung-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.6
    • /
    • pp.117-125
    • /
    • 2004
  • This paper describes the test technique for the full-scale airframe durability test according to the military handbook(MIL-HDBK-1530) and ASIP(Aircraft Structure Integrity Program) to evaluate structural integrity and to obtain basic data for IPA(Initial Production Approval) of the Korean advanced trainer(T-50). This paper covers the full-scale airframe floating setup technique, the optimized test load simulation method, test rig design technique, test setup design and installation techniques, test safety device design and operation technique, and durability test results. As 1st life durability test was successfully performed, it was confirmed that this method is available in a full-scale airframe structural test.