• Title/Summary/Keyword: IT Field

Search Result 30,841, Processing Time 0.054 seconds

Fabrication and magnetic properties of hexagonal BaFe12O19 ferrite obtained by magnetic-field-assisted hydrothermal process

  • Zhang, Min;Dai, Jianming;Liu, Qiangchun;Li, Qiang;Zi, Zhenfa
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1426-1430
    • /
    • 2018
  • High magnetic field effects on the microstructure and magnetic properties of $BaFe_{12}O_{19}$ hexaferrites synthesized hydrothermal method have been investigated. The obtained results indicate that the lattice constant decreases gradually as the magnetic field strength increases, which may be attributed to the lattice distortion resulted from the high magnetic field. Polycrystalline $BaFe_{12}O_{19}$ samples prepared under magnetic field strength at zero and 5 T are single phase. It is found that application of external magnetic field during synthesis can induce orientated growth of the hexaferrite crystals along the easy magnetic axis. The magnetic properties can be effectively regulated by an application of high magnetic fields. It is observed that the $BaFe_{12}O_{19}$ prepared under a 5 T magnetic field exhibits a higher room-temperature saturation magnetization (66.3 emu/g) than that of the sample (43.6 emu/g) obtained without magnetic field. The results can be explained as the enhanced crystalline, improvement of $Fe^{3+}$ ions occupancy and the oriented growth induced by the external magnetic field. The growing orientation of particles gives rise to increased coercivity due to the enhancement in shape anisotropy. It is expected that an application of magnetic field during the formation of magnetic nanoparticles could be a promising technique to modify magnetic properties with excellent performance.

Film Thickness Dependence of Ac High Field for Low Density Polyethylene (저밀도 폴리에틸렌의 고전계 파형에 대한 필름 두께 의존성)

  • Choi, Yong-Sung;Wee, Sung-Dong;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.45-49
    • /
    • 2008
  • Polyethylene is widely used as the insulator for power cable. To investigate the conduction mechanism for power cable insulation under ac high field, it is very important to acquire the dissipation current under actual running field. Recently, we have developed the unique system, which make possible to observe the nonlinear dissipation current waveform. In this system, to observe the nonlinear properties with high accuracy, capacitive current component is canceled by using inverse capacitive current signal instead of using the bridge circuit for canceling it. We have already reported that the dissipation currents of $40\;{\mu}m$ thick LDPE film at 10 kV/mm and over 140 Hz, it starts to show nonlinearity and odd number's harmonics were getting large. To investigate the conduction mechanis ms in this region, especially space charge effect, various kinds of estimation, such as time variations of instantaneous resistivity for one cycle, FFT spectra of dissipation current waveforms and so on, has been examined. As the results of these estimations, it was found that the dissipation current will depend on not only the instantaneous value of electric field but also the time differential of applied electric field due to taking a balance between applied field and internal field. Furthermore, two large peaks of dissipation current for each half cycle were observed under certain condition. In this paper, to clarify the reason why it shows two peaks for each half cycle, the film thickness dependences of dissipation current waveforms were observed by using the three different thickness LDPE films.

  • PDF

A study on the effect of the condition number in the magnetic field mapping of the Air-Core solenoid

  • Huang, Li;Lee, Sangjin
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.2
    • /
    • pp.31-35
    • /
    • 2015
  • Mapping is a useful tool in the magnetic field analysis and design. In some specific research area, such as the nuclear magnetic resonance (NMR) or the magnetic resonance imaging (MRI), it is important to map the magnetic field in the interesting space with high accuracy. In this paper, an indirect mapping method in the center volume of an air-core solenoid is presented, based on the solution of the Laplace's equation for the field. Through the mathematical analysis on the mapping calculation, we know that the condition number of the matrix, generated by the measurement points, can greatly affect the error of mapping result. Two different arrangement methods of the measurement points in field mapping are described in this paper: helical cylindrical line (HCL) method and parallel cylindrical line (PCL) method. According to the condition number, the HCL method is recommended to measure the field components using one probe. As a simple example, we mapped the magnetic fields in a MRI main magnet system. Comparing the results in the different methods, it is feasible and convenient to apply the condition number to reduce the error in the field mapping calculation. Finally, some guidelines were presented for the magnetic field mapping in the center volume of the air-core solenoid.

The generation and characteristics of the dominant field in CTL cell (CTL cell에서의 우세장 발생과 특성)

  • Park, Unghee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.5
    • /
    • pp.1055-1063
    • /
    • 2013
  • CTL cell that is one of the standard electromagnetic generation equipment can measure the characteristic of the electromagnetic susceptibility and the electromagnetic interference. In case of being input the same magnitude signal with the phase difference of 0o or the phase difference of 180o at two input ports of CTL cell to be the fundamental resonant frequency(TE011) of 2.20GHz, the characteristics of the electric field and the magnetic field at the uniform area were measured. And, it measured the electric field characteristic due to the variation of the input power, the test position and the input frequency under the dominant E-field and the dominant H-field of CTL cell. Using these mesuremed data, it examined the operation characteristic and the available frequency band of CTL cell.

The Development of Electromagnetic Field Analysis Software for Virtual Training (가상 교육용 전자장 해석 프로그램 개발)

  • Wee, Sang Bong;Kim, Ki Beom
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.2 no.2
    • /
    • pp.55-60
    • /
    • 2010
  • We usually encounter Electro-magnetics phenomenons and only feel some part of that, but it is hard to feel it visually. Moreover understanding physically and quantitatively is not a easy work. These electrostatic field theory, magnetostatic field theory and interchange magnetic field theory combined with electromagnetic field are formulated experimentally and theoretically by James Clerk Maxwell in 1873. Electromagnetic field takes electro-magnetic phenomenons as a expansion of formula originated in Maxwell equations. Since this is based on expansion of formula, it is hard to understand for many students not only middle school and high school students learning it at the first time but also college students studying physics as a elementary class and even majors in electromagnetic field. The program is developed as a visual aid to cope with these problems, and even to deal with complex problem to estimate solution using numerical method.

  • PDF

A Study on Protective Coordination Setting of Positive Offset Mho Loss of Field Relay (Positive Offset Mho 계자 상실 계전기 보호 협조 정정에 관한 연구)

  • Kim, Kwnag-Hyun;Park, Ji-Kyung;Kim, Jun-Hyeok;Kim, Doo-Ung;Kang, Sung-Bum;Kim, Chul-Hwan;Lyu, Young-Sik;Yang, Jeong-Jae;Ko, Yun-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1326-1333
    • /
    • 2016
  • It is important to clear the fault and prevent resulting in damage to power system. Although the frequency of generator internal fault is relatively low, it can lead to incalculable damage to power system as well as generator. Especially, loss of field on generator can cause the generator to lose synchronism for a short time if it is not removed promptly. Therefore, it is needed to conduct research on loss of field relay for detecting or clearing the loss of field. However, the setting of the relay may vary in generator operator or engineer, and the relay is not coordinated well with other elements associated with loss of field. In this paper, we address specifically the coordination of positive offset mho loss of field relay which is one of the protection schemes for loss of field. Computer simulations are performed by using ElectroMagnetic Transients Program-Restructured Version (EMTP-RV) based on actual data.

Analysis and Comparison about NPS of Plane Field and Alpine Field (평지밭과 고랭지밭의 비점오염에 대한 분석과 비교)

  • Choi, Yong-hun;Won, Chul-hee;Seo, Ji-yeon;Shin, Min-Hwan;Yang, Hee-jeong;Lim, Kyoung-jae;Choi, Joong-dae
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.682-688
    • /
    • 2009
  • A plane field and a sloped field located at low-land plane and alpine areas, respectively, were monitored with respect to runoff, water quality and fertilizer uses from March to December, 2008. Runoff volume and Non-Point Source (NPS) loads were estimated and analyzed with respect to fertilizer uses. Total TN and TP loads from the sloped field were higher than those from plane field because of larger chemical uses in the alpine field than in the plane field. Organic matter load from plane field was higher than that from sloped field because more organic compost was applied to plane field than to sloped field. Event Mean Concentration (EMC) of measured water quality indices were relatively higher in both fields. Organic matter load per 1 mm rainfall were higher in plane field and TN and TP loads per 1 mm rainfall were higher in sloped field than those in respective comparing field. It was concluded that the type and application method of fertilizer could play an important role in the estimation of NPS pollution loads and the development of Best Management Practices (BMPs). However, it was recommended that long-term monitoring is necessary to better describe the relationship between fertilizer uses and water quality from agricultural fields because numerous natural and management factors other than fertilizer also affect runoff quality.

A Study on Present Condition and Educational Improvement Plan of Building Services System (건축설비 관련 현황과 교육면에서의 개선방향 고찰)

  • Lee, Chul-Goo
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.12 no.3
    • /
    • pp.50-57
    • /
    • 2013
  • The education of building services field at university is not enough, although the field has become to be very important in architectural engineering. This lack of education is one of the reason that the level of domestic building services field is lower than that in developed countries. Present conditions of related laws, fields of work after graduation and education at university in building services field have been studied, and education conditions have been investigated divided into four-year architectural engineering course and five-year architecture course. Though building services field has become more important at university education, the number of credits and professor of the field is still small than other fields of architectural engineering. More practical curriculums are necessary to meet the expectation of companies, and it will be one of the method to meet it that criteria of curriculum constitution is according to ABEEK(Accreditation Board for Engineering Education of Korea) in more architectural engineering department.

A Study on the Outlet Drain Discharge from Paddy Field (논의 배수물꼬의 유량에 관한 기초연구)

  • 최진규;김현영;손재권
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.2
    • /
    • pp.134-142
    • /
    • 1997
  • This study was performed to evaluate the drain runoff characteristics from one paddy field, and to provide the basic data required for the determination of flood discharge and unit drainage water for drainage improvement and farmland consolidation. For this purpose, under the assumption that drain discharge from paddy field was similar to outflow of reservoir, runoff model based on storage equation was applied to the experimental field, and simulated results were compared to the measured discharge at weir point. To estimate effective storage volume of paddy field with water depth, 4 regression formula were examined such as linear, exponential, power, and combined. From the observed runoff characteristics, it was shown to be 3.3~16.3${\ell}$/sec in weir discharge, 57.2~98% in runoff ratio, and relative error of simulated result was 3.0~39.4%, 8.5 ~56.0 % for peak flow and runoff ratio, respectively. Curve number by SCS method was calculated as mean value of 96.4 using measured rainfall and runoff data, it was considered relatively high because paddy field has generally flooding depth contrary to the upland watershed area.

  • PDF

On the Time-Mean Drift Force Acting on a Floating Offshore Structure in Wave (부유식 해양구조물에 작용하는 시감평균 파표류력에 관한 고찰)

  • 홍도천
    • Journal of Ocean Engineering and Technology
    • /
    • v.16 no.3
    • /
    • pp.8-18
    • /
    • 2002
  • Formulation of the far-field method for the prediction of time-mean hydrodynamic force and moment acting on a 3-D surface-piercing body in waves is reviewed. It is found that the inequality between the weight of the floating body and its buoyancy force permits the replacement of the fluid particles inside the control surface by the fluid particles outside the control surface. Under such circumstances, momentum exchanges across the control surface make the time-mean value of the time rate of the momentum of the fluid inside the control surface non-vanishing. It is a second-order quantity which is hard to calculate by the far-field method. The drift forces and moments on half-immersed ellipsoids are calculated by both the far-field method and the near-field method. The discrepancy between two numerical results is presented and discussed.