• Title/Summary/Keyword: High resolution MS

Search Result 211, Processing Time 0.021 seconds

Development of A High-Speed Digital Maximum Selector Circuit With Internal Trigger-Signal Generator (내부 트리거 발생회로를 이용한 고속의 디지털 Maximum Selector 회로의 설계)

  • Yoon, Myung-Chul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.2
    • /
    • pp.55-60
    • /
    • 2011
  • Most of neural network chips use an analog-type maximum selector circuit (MS). As the increase of integration level, the analog MS has difficulties in achieving sufficient resolution. Contrary, the digital-type MS is easy to get high resolution but slower than its analog counterparts. A new high-speed digital MS circuit called MSIT (Maximum Selector with Internal Trigger-signal) is presented in this paper. The MSIT has been designed to achieves both the high reliability by using trigger-signals and high speed by removing the unnecessary waiting times. The response time of MSIT is 3.4ns for 32 data with 10-bit resolution in the simulation with 1.2V, $0.13{\mu}m$-process model parameters, which is much faster than its analog counterparts. It shows that digital MS circuits like MSIT can achieve higher speed as well as higher resolution than analog MS circuits.

Analysis of Ultra Pure Sulfuric Acid for Semiconductor Using High Resolution ICP-MS (고분해능 ICP-MS를 이용한 반도체용 고순도 황산 분석)

  • Heo, Y.W.;GiI, J.I.;Lim, H.B.
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.311-315
    • /
    • 1998
  • Ultra trace metal impurities of high-purity sulfuric acid for semiconductor process have been determined in the concentration of lower than ppb (ng/g) level using high resolution inductively coupled plasma mass spectrometer (HR-ICP-MS).The acid samples were evaporated and concentrated by the factor of 20. No clement in the acids exceeded 1ppb level and most of the clements were determined below 10ppt (pg/g). Elements without spectral interference in mass spectrum, such as In, V, Mn, etc, were determined in the concentration of below 1 ppt level The recoveries in the range of 72% to 127.2% for 0.5 ppb spiked sample were obtained.

  • PDF

Establishment of the Analytical Method for Residual Pharmaceuticals in Raw Water Using Online Sample Preparation and High Resolution Orbitrap LC/ESI-MS (온라인 자동화 시료 전처리 및 HR Orbitrap LC/ESI-MS를 이용한 환경시료 중 잔류 의약물질 분석방법 확립)

  • Hwang, Yoonjung;Sin, Sanghee;Park, Jongsuk
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.3
    • /
    • pp.409-419
    • /
    • 2013
  • In this study, the analytical method for 27 residual pharmaceuticals in raw water was developed. Online sample preconcentration/extraction and analysis with high resolution Orbitrap mass spectrometry (LC-ESI/Orbitrap MS) were performed. The calibration curves showed good linearities (above $r^2$ = 0.998) in the range of 5 ~ 1,000 ng/L. The method detection limit and the limit of quantification were 1.1 ~ 10.0 ng/L and 3.4 ~ 31.7 ng/L, respectively. Recoveries of the target compounds were between 70.1% and 115.8% (except cefadroxil, cefradine, vancomycin, and iopromide (50.2 ~ 67.0%)). The optimized analytical method can be useful to determine the residual pharmaceuticals in raw water.

Fusion Techniques Comparison of GeoEye-1 Imagery

  • Kim, Yong-Hyun;Kim, Yong-Il;Kim, Youn-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.6
    • /
    • pp.517-529
    • /
    • 2009
  • Many satellite image fusion techniques have been developed in order to produce a high resolution multispectral (MS) image by combining a high resolution panchromatic (PAN) image and a low resolution MS image. Heretofore, most high resolution image fusion techniques have used IKONOS and QuickBird images. Recently, GeoEye-1, offering the highest resolution of any commercial imaging system, was launched. In this study, we have experimented with GeoEye-1 images in order to evaluate which fusion algorithms are suitable for these images. This paper presents compares and evaluates the efficiency of five image fusion techniques, the $\grave{a}$ trous algorithm based additive wavelet transformation (AWT) fusion techniques, the Principal Component analysis (PCA) fusion technique, Gram-Schmidt (GS) spectral sharpening, Pansharp, and the Smoothing Filter based Intensity Modulation (SFIM) fusion technique, for the fusion of a GeoEye-1 image. The results of the experiment show that the AWT fusion techniques maintain more spatial detail of the PAN image and spectral information of the MS image than other image fusion techniques. Also, the Pansharp technique maintains information of the original PAN and MS images as well as the AWT fusion technique.

A Study of the Potential Interference of ArC+ on the Direct Determination of Trivalent Chromium and Hexavalent Chromium Using Ion Chromatography Coupled with ICP-MS

  • Nam, Sang-Ho;Park, Young-Il;Kim, Jae-Jin;Han, Sun-Ho;Kim, Won-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.4
    • /
    • pp.447-451
    • /
    • 2004
  • Low and high resolution inductively coupled plasma mass spectrometry (ICP-MS) coupled with ion chromatography (IC) has been investigated for speciation of Cr(III) and Cr(VI). In particular, the interference of ArC^+formed by the carbon in a sample on the simultaneous determination of Cr(III) and Cr(VI) has been studied. In chemical speciation, this study shows that quadrupole type ICP-MS with low resolution has a limitation of simultaneous determination fo chromium species if the sample contains the carbon elements. The interference problems can be solved by high resolution ICP-MS.

Development of a SHA with 100 MS/s for High-Speed ADC Circuits (고속 ADC 회로를 위한 100 MS/s의 샘플링의 SHA 설계)

  • Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.2
    • /
    • pp.295-301
    • /
    • 2012
  • In this article, we have designed SHA, which has 12 Bit resolution at an input signal range of 1 $V_{pp}$ and operates at a sampling speed of 100 MS/s in order to use at front of high speed ADC. SFDR(Spurious Free Dynamic Range) of the proposed system drops to approximately 66.3 dB resolution when the input frequency is 5 MHz, and the sampling frequency is 100 MHz, however, the circuit without a feedthrough has 12 bit resolution with approximately 73 dB.

Gas Chromatography-High Resolution Tandem Mass Spectrometry Using a GC-APPI-LIT Orbitrap for Complex Volatile Compounds Analysis

  • Lee, Young-Jin;Smith, Erica A.;Jun, Ji-Hyun
    • Mass Spectrometry Letters
    • /
    • v.3 no.2
    • /
    • pp.29-38
    • /
    • 2012
  • A new approach of volatile compounds analysis is proposed using a linear ion trap Orbitrap mass spectrometer coupled with gas chromatography through an atmospheric pressure photoionization interface. In the proposed GC-HRMS/MS approach, direct chemical composition analysis is made for the precursor ions in high resolution MS spectra and the structural identifications were made through the database search of high quality MS/MS spectra. Successful analysis of a complex perfume sample was demonstrated and compared with GC-EI-Q and GC-EI-TOF. The current approach is complementary to conventional GC-EI-MS analysis and can identify low abundance co-eluting compounds. Toluene co-sprayed as a dopant through API probe significantly enhanced ionization of certain compounds and reduced oxidation during the ionization.

Evaluation of pesticide residue analysis of dieldrin in soil using a high resolution gas chromatograph/mass spectrometer (HR-GC/MS)

  • Hwang, Jae-Bok;Park, Tae-Seon
    • Korean Journal of Agricultural Science
    • /
    • v.43 no.4
    • /
    • pp.634-640
    • /
    • 2016
  • The objective of this study was to evaluate the effectiveness of using HR-GC/MS for the rapid screening of dieldrin residues in soils. Persistent organic pollutants (POPs) of organochlorine pesticides such as dieldrin, were analyzed in sedimentary rock and granite rock collected from greenhouses, Niigata, Japan. Dieldrin remains in Japanese farming soils, more than 40 years after their use as insecticides was prohibited. The averages in soil moisture ranged from 2.79% to 7.20% in soils derived from sedimentary rock and from 25.59% to 31.40% in soils derived from granite rock. Mean concentrations of dieldrin residues in sedimentary rock and granite rock were $39.7ng\;g^{-1}$ and $40.51ng\;g^{-1}$, respectively. Dieldrin residue was detected at a slightly higher concentration in granite rock than sedimentary rock samples. There was no consistency between the two soils or between surface and subsurface soils. The coefficients of variation of the two soils were 10.6% and 8.7%, respectively. These results suggest that our high-resolution mass spectrometry detector (HR-GC/MS) is effective at analyzing residual organochlorine pesticides in soil. In order to increase the precision and sensitivity for chemical analysis of POPs, high-resolution gas chromatography coupled with a HR-GC/MS is highly recommended.

A Design on the A/D converter with architective of ${\sum}-{\Delta}$ (${\sum}-{\Delta}$ modulator의 구조를 갖는A/D 변환기 설계)

  • 윤정식;정정화
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.1C
    • /
    • pp.14-23
    • /
    • 2003
  • This thesis proposes a sigma-delta modulator architecture with 2 Ms/s data rate and 12 bit resolution. A sigma-delta modulate has the features of oversampling and noise shaping. With these features, it can be connected with low resolution A/D converter to achieve higher resolution A/D converter. Most previous researches have been concentrated on high resolution but low data rate applications, e.g. audio applications. But, in order to be applied to various applications such as wireless data communication, researches on sigma-delta modulator architecture for higher data rate are required. The proposed sigma-delta modulator architecture has the sampling rate of 16 times Nyquist rate to achieve high data rate, and consists of a cascade of two 2nd order sigma-delta modulator to get relatively high resolution. The experimental result shows that the proposed architecture achieves 12-bit resolution at 2 Ms/s data rate.

Method for Restoring the Spatial Resolution of KOMPSAT-3A MIR Image (KOMPSAT-3A 중적외선 영상의 공간해상도 복원 기법)

  • Oh, Kwan-Young;Lee, Kwang-Jae;Jung, Hyung-Sup;Park, Sung-Hwan;Kim, Jeong-Cheol
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_4
    • /
    • pp.1391-1401
    • /
    • 2019
  • The KOMPSAT-3A is a high-resolution optical satellite launched in 2015 by Korea Aerospace Research Institute (KARI). KOMPSAT-3A provides Panchromatic (PAN-0.55 m), Multispectral (MS-2.2 m), and Mid-wavelength infrared (MIROR-5.5 m) image. However, due to security or military problems, MIROR image with 5.5m spatial resolution are provided down sampled at 33 m spatial resolution (MIRrd). In this study, we propose spatial sharpening method to improve the spatial resolution of MIRrd image (33 m) using virtual High Frequency (HF) image and optimal fusion factor. Using MS image and MIRrd image, we generated virtual high resolution (5.5 m) MIRORfus image and then compared them to actual high-resolution MIROR image. The test results show that the proposed method merges the spatial resolution of MS image and the spectral information of MIRrd image efficiently.