• 제목/요약/키워드: Heater electrode

검색결과 44건 처리시간 0.022초

유한요소법에 의한 적층형 세라믹 히터의 전극 패턴 최적화 (Optimization of Electrode Pattern for Multilayer Ceramic Heater by Finite Element Method)

  • 한윤수;김시연;여동훈
    • 한국전기전자재료학회논문지
    • /
    • 제30권12호
    • /
    • pp.776-781
    • /
    • 2017
  • In this study, we investigated the effect of electrode pattern design on the thermal shock resistance and temperature uniformity of a ceramic heater. A cordierite substrate with a low thermal expansion coefficient was fabricated by tape casting, and a tungsten electrode was printed and used as a heating element. The temperature distribution of the ceramic heater was calculated by a finite-element method (FEM) by considering various electrode patterns, and the tensile stress distribution due to the thermal stress was calculated. In the electrode pattern with a single-line width, the central part of the ceramic heater was heated to the maximum temperature, and the position of the ceramic heater having a double-line width was changed to the maximum temperature, depending on the position of the minimum line width pattern. The highest tensile stress was found along the edges of the ceramic heater. The temperature gradient at the edge determined the tensile stress intensity. The smallest tensile stress was observed for electrode pattern D, which was expected to be advantageous in resisting thermal shock failures in ceramic heaters.

발열 전극에 따른 상변화 메모리 소자의 전자장 및 열 해석 (Electromagnetic and Thermal Analysis of Phase Change Memory Device with Heater Electrode)

  • 장낙원;마석범;김홍승
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권4호
    • /
    • pp.410-416
    • /
    • 2007
  • PRAM (Phase change random access memory) is one of the most promising candidates for next generation non-volatile memories. However, the high reset current is one major obstacle to develop a high density PRAM. One way of the reset current reduction is to change the heater electrode material. In this paper, to reduce the reset current for phase transition, we have investigated the effect of heater electrode material parameters using finite element analysis. From the simulation. the reset current of PRAM cell is reduced from 2.0 mA to 0.72 mA as the electrical conductivity of heater is decreased from $1.0{\times}10^6\;(1/{\Omega}{\cdot}m$) to $1.0{\times}10^4\;(1/{\Omega}{\cdot}m$). As the thermal conductivity of heater is decreased, the reset current is slightly reduced. But the reset current of PRAM cell is not changed as the specific heat of heater is changed.

은나노선/Ni 산화물 고내열성 하이브리드 투명전극의 형성 (Fabrications of Silver Nanowire/NiO Based High Thermal-Resistance Hybrid Transparent Electrode)

  • 정성훈;이승훈;김도근
    • 한국표면공학회지
    • /
    • 제50권6호
    • /
    • pp.486-491
    • /
    • 2017
  • Silver nanowire (AgNW) transparent electrode is one of next generations of flexible and transparent electrode. The electrode shows high conductivity and high transparency comparable to ITO. However, the electrode is weak against heat. The wires are separated into nanodots at temperature above $200^{\circ}C$. It causes the electrical resistance increase. Moreover, it is vulnerable to oxygen and moisture in the atmosphere. The improvement of thermal and moisture resistance of silver nanowire transparent electrode is the most important for commercializing. We proposed silver nanowires transparent electrode which is capped with very thin nickel oxide layer. The nickel oxide layer is five nanometers of thickness, but the heat and moisture resistance of the transparent electrode is effectively improved. The AgNW/NiO electrode can endure at $300^{\circ}C$ of temperature for 30 minutes, and resistance is not increased for 180 hours at $85^{\circ}C$ of temperature and 85% of relative humidity. We showed an applications of transparent and flexible heater using the electrode, the heater is operated more than $180^{\circ}C$ of temperature.

원형 다중전극을 이용한 DNA 조작소자 (Micromachined DNA Manipulation Device Using Circular Multi-Electrodes)

  • 문상준;윤재영;남홍길;지연태;이승섭
    • 대한기계학회논문집A
    • /
    • 제27권7호
    • /
    • pp.1071-1075
    • /
    • 2003
  • In this paper, we present a DNA manipulation device in the reaction chamber, which consists of a center electrode and circular outer electrodes of a reaction unit. The charged bio-molecules, DNA, are manipulated by the charge of the electrode in reaction unit. Controlling the induced dynamic electric field between the center electrode and the outer electrodes, concentration / repulsion / manipulation of bio-molecules are enabled at a periphery of electrode. Concentration of the fluorescent DNA at the center electrode is observed by applying +2V. Subsequently, applying -2V, the concentrated DNA is repelled rapidly from the center electrode, which makes dispersion completely in 0.5second. Furthermore, repeated applying +1V/-1V every 5 seconds at each outer electrode, we can circulate the DNA. We also investigate a micro-heater and sensor for DNA manipulation and reaction temperature. The coefficient of heat-resistance and heater temperature characteristic is 0.0043 and 100$^{\circ}C$/sec, respectively.

솔레노이드형 고온초전도코일 모의전극계에서 부분 및 완전파괴전압특성 연구 (A Study of PBD and BD Voltage Characteristics in the Simulate Electrode System of Solenoid Type High Temperature Superconducting Coils)

  • 석복렬
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.94-98
    • /
    • 2002
  • The Partial breakdown (PBD) and complete breakdown (BD) voltage characteristics in a composite insulation system of glass fiber reinforced plastics (GFRP) and liquid nitrogen are investigated to find the PBB and BD characteristics in solenoid type high temperature superconducting (HTS) coils at quench. The electrode system used is made from a coaxial spiral coil-to-cylindrical electrode with an insulation barrier and spacers, and is immersed in liquid nitrogen. A heater is mounted inside the coil electrode to generate boiling which occurs on quenched superconducting coils. The experimental results show that: (1) breakdown voltages are affected severely by the risetime of the applied voltage and the PBD inception voltage, (2) two kinds of BD mechanisms are found depending on the shape of the spacer, length of cooling channel and heater power.

마이크로 가스센서를 위한 저전력 마이크로 히터의 제조 I. 유한요소법에 의한 열분포해석 (Fabrication of Low Power Micro-heater for Micro-Gas Sensor I. The Thermal Distribution Analysis by The Finite Element Method)

  • 정완영;임준우;이덕동;노보루 야마조에
    • 센서학회지
    • /
    • 제6권4호
    • /
    • pp.337-345
    • /
    • 1997
  • 마이크로 가스센서 제조를 위해 PSG/$Si_{3}N_{4}$를 다이아프램으로 하고 Pt 패턴을 히터로 하는 마이크로 히터를 설계하였다. 백금히터와 감지막을 위한 백금전극을 동일평면에 설계하여 하나의 노광공정으로 실현하도록 센서의 형태를 가정하였다. 마이크로 가스센서의 가열부의 열적거동을 유한요소법에 의해 수치해석하므로써 다이아프램부분의 온도분포, 소비전력 및 감지막부분의 온도분포를 예측할 수 있었다. 본 연구에서 제안된 히터와 감지막이 동일 평면에 이웃하는 구조의 센서와 일반적 마이크로센서구조인 감지막/절연막/히터의 구조를 갖는 센서의 열적거동을 비교 분석하였다.

  • PDF

연속흐름 중합효소연쇄반응칩 제작을 위한 인듐 산화막 전극의 특성분석 (Characteristics of Indium-Tin-Oxide electrode for continuous-flow PCR chip)

  • 정승룡;이인제;김준혁;김한수;김재완;최영진;강치중;김용상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1386-1387
    • /
    • 2006
  • PDMS와 ITO 유리를 이용하여 continuous-flow PCR chip을 제작하였다. PDMS를 이용하여 microchannel을 형성하여 주었고, ITO electrode를 heater와 sensor로 사용하기 위하여 반도체 공정을 통해 패턴을 형성하였다. microchannel내에 흐르는 시료의 온도를 제어하기 위하여 heater와 sensor를 calibration을 하였다. ITO heater는 인가된 전압에 대해 매우 선형적인 발열을 하였으며, ITO sensor는 온도에 대해 선형적인 저항 변화를 나타낸 바, 그 결과 continuous-flow PCR chip의 정확한 온도 제어가 가능하였다.

  • PDF

스크린 프린팅 공정에 의해 제조된 비데용 Ag-Pd 봉형 발열체의 내구성 및 물성 평가 (Durability and Characteristics of Ag-Pd Rod Heater for Bidet Fabricated by Screen Printing Process )

  • 박태웅;현다은;김익수;이성철;이연숙;김용남;이동원;오종민
    • 한국전기전자재료학회논문지
    • /
    • 제36권1호
    • /
    • pp.81-87
    • /
    • 2023
  • Heaters using the resistance heating principle are used in various industrial fields that require heat and are also essentially used in bidet among small home appliances. A planar heater and a coil-inserted heater mounted on a conventional commercially used bidet have disadvantages and limitations of complicated manufacturing process and local heating. In this study, silver-palladium (Ag-Pd) powder material was used for a screen-printing process that is more advantageous in achieving simplification than the existing process, and a rod-type heater for bidet was manufactured. The on-off cycle test under actual conditions was conducted to confirm the durability and the capability of the fabricated heater, and the fabricated heater operated more than 2,600 on-off cycles, which means it could be applied for a commercial product. In addition, through the on-off cycles under harsh conditions, the cause of failure was identified after the test that the durability limit temperature of the heater was 850℃. Through Ag-Pd rod heater in this study, it is expected to contribute to the efficient development of electrode materials for heaters and the improvement of the durability of heaters in the future.

단층 탄소나노튜브의 일산화질소 가스에 대한 감응특성과 열처리 효과 (NO Gas Sensing Characteristics of Single-Walled Carbon Nanotubes and Heating Effect)

  • 김민주;윤광현;허증수
    • 센서학회지
    • /
    • 제13권4호
    • /
    • pp.292-297
    • /
    • 2004
  • Carbon nanotubes (CNT) were synthesized by arc-discharge method. To fabricate CNT sensor, CNT powder was dispersed in ${\alpha}$-Terpinol($C_{10}H_{17}OH$) solution. The CNT tilms were fabricated by screen printing method on the interdigitated Pt/Pd alloy electrode. The microstructure of CNT film was observed by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). In order to investigate the gas sensing characteristics of the film, the CNT film was experimented to measure NO response and recovery time. The CNT sensor with a heater was compared to that without a heater. And this sensor shows better reproductibility and faster recovery time than another CNT sensors. We suggest the possibility to utilize a CNT as new sensing materials for environmental monitoring.

동일면상에 heater와 감지전극을 형성한 마이크로가스센서의 제작 및 특성 (Characteristics and Fabrication of Micro-Gas Sensors with Heater and Sensing Electrode on the Same Plane)

  • 임준우;이상문;강봉휘;정완영;이덕동
    • 센서학회지
    • /
    • 제8권2호
    • /
    • pp.115-123
    • /
    • 1999
  • PSG(800nm)/$Si_3N_4$ (150nm)로 구성된 유전체 membrane 윗면에 heater와 감지전극을 등일면상에 동시에 형성하였다. 제작된 소자의 전체 면적은 $3.78{\times}3.78mm^2$이고, diaphragm의 면적은 $1.5{\times}1.5mm^2$이며, 감지막치 면적은 $0.24{\times}0.24mm^2$였다. 그리고 diaphragm내의 열분포 분석을 유한요소법을 이용하여 수행하였으며, 실제로 제작된 소자의 열분포와 비교하였다. 소비전력은 동작온도 $350^{\circ}C$에서 약 85mW였다. Sn 금속막을 상온과 $232^{\circ}C$의 두 가지 기판온도에서 열증착하였고, 이를 $650^{\circ}C$의 산소분위기에서 3시간 열산화함으로써 $SnO_2$ 감지막을 형성하였다. 그리고 이를 SEM과 XRD로 특성을 분석하였다. 제작된 소자에 대해서 온도 및 습도에 대한 감지막의 영향 및 부탄가스에 대한 반응특성도 조사하였다.

  • PDF