• Title/Summary/Keyword: Fire Preparation

Search Result 126, Processing Time 0.037 seconds

Comparative Analysis of Preparation Time between Rack-type and Reel-type Fire Hoses (호스걸이형 소방호스와 호스릴 소방호스의 전개시간 비교 분석)

  • Hong, Suk-Hwan;Kim, Seo-Young;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.4
    • /
    • pp.49-53
    • /
    • 2021
  • The objective of this study was to understand which type of fire hose should be placed in indoor fireplug box upon analyzing the preparation time between rack-type fire hose and reel-type one. With respect to the type of hose, rack-type stacking method was used and hose preparation time was measured with 5 times of repeat test, separating men and women. Study results reveal that preparation time of reel-type fire hose took longer than that of rack-type one in both men and women. For both rack-type hose and reel-type hose, preparation time by two persons took shorter than that by one man. Also, preparation time by three persons took shorted than that by two women. Preparation time for both rack-type hose and reel-type one by men took shorter than that by women. In summary, it was confirmed that rack-type hose could be prepared within shorter time than reel-type one. Since the size of drum set in the reel-type fire hose is relatively small, it had some difficulty in preparation of fire hose timely.

Research about Members' Recognition of Crisis Management System to Preparation Phase of Terror Countermove - Focusing on the Fire Fighting Public Service Personnel - (테러대응 준비단계의 위기관리체제 구성원의 인식에 관한 연구 - 소방지방공무원을 중심으로 -)

  • Oh, Tae-Kon
    • Fire Science and Engineering
    • /
    • v.21 no.2 s.66
    • /
    • pp.24-29
    • /
    • 2007
  • This research is accomplished for the purpose of providing fundamental materials to improve the level of prevention consciousness by deducting awareness difference through analyzing awareness level about terror preparation of members of crisis management system - the public service personnel in charge of crisis management in a self-governing body and the fire fighting public service personnel. For this research, That is measured through the priority order survey about a specialty of public service personnel in charge of crisis management and a level of crisis prepartion and a cooperation between crisis management system and etc. As a result of analysis, it is revealed that there is a difference about the priority order of measurement variable to terror preparation but all the members are recognizing the importance of that.

Evaluation on the Properties of Fire Retardant Surface Preparation Mortars (화재 지연형 바탕조정재의 기초물성 평가에 관한 연구)

  • Ryu, Hwa-Sung;Shin, Sang-Heon;Kim, Deuck-Mo;Song, Sung-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.6
    • /
    • pp.559-567
    • /
    • 2018
  • In the case of fire, surface treatment agents used in external insulation finishing methods are substances that are vulnerable to fire due to thin finishes and the combustion of polymers. In this study, it was expected that the performance of surface preparation mortars could be improved by using expandable graphite with excellent thermal performance. Experimental results showed that the mechanical properties of surface preparation mortar were improved by using the fly ash and silica fume. Surface treatment materials using expanded graphite have a characteristic of expanding when a fire occurs. It has been shown that heat-swellable surface treatment materials can reduce the penetration of heat sources into the surface of synthetic insulation.

Comparison Analysis of Ready to Use Time Depending on The Type of Public Fire Hydrant of Fire-fighting Water Facility (소방용수시설의 공설소화전 종류에 따른 사용 준비시간 비교분석)

  • Jeon, Jai-In;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.4
    • /
    • pp.87-92
    • /
    • 2019
  • The purpose of this study is to investigate the preparation time of fire-fighting water for public fire hydrants and ground, underground fire hydrants. The equipment preparation time for stage 1 was 20.50 seconds for ground type and 24.67 seconds for underground type. The reason for this difference in preparation time is that an underground fire hydrant requires additional standpipes to connect to the main conduit of Paru and the underground hydrant, which open the manhole cover. Water tank Maintenance joint with water hose male coupling of the second stage was similar to that of the ground type of 48.50 seconds and underground water tipe of 49.00 seconds. This is because the operation of connecting the fire hose to the maintenance tank of the water tank car is the same. In the third stage, the water pipe connection was 43 seconds for ground type and 174.33 seconds for underground type. The reason why the time for connecting the water pipe to the fire hydrant is large difference is that the underground fire hydrant is opened by opening the manhole cover, After connecting the stand pipe to the fire hydrant, the additional process of connecting the water pipe to the stand pipe is required, which is considered to have greatly increased the time required. The opening of Water Control Valve and spindle Valve in the fourth stage was 66.50 seconds for the ground type and 78.83 seconds for the underground type. This difference is due to the fact that the spindle of the ground fire hydrant is located on the main body and can be easily opened, but the underground type is located next to the main body under the manhole and requires additional time to connect the opening equipment.

Mechanical and Fire Resistance Properties of Surface Preparation Mortar in Buildings Using Expanded Graphite (팽창흑연을 활용한 건축물 외단열 바탕조정재의 역학 및 연소 특성평가)

  • Ryu, Hwa-Sung;Shin, Sang-Heon;Song, Sung-Young;Kim, Deuak-Mo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.4
    • /
    • pp.395-404
    • /
    • 2019
  • In the case of fire, surface treatment agents used in external insulation finishing methods are substances that are vulnerable to fire due to thin finishes and the combustion of polymers. In this study, it was expected that the performance of surface preparation mortars could be improved by using expandable graphite with excellent thermal performance. Experimental results showed that the mechanical properties of surf ace preparation mortar were improved by using the fly ash and silica fume. Surface treatment materials using expanded graphite have a characteristic of expanding when a fire occurs. It has been shown that heat-swellable surface treatment materials can reduce the penetration of heat sources into the surface of synthetic insulation.

Analysis of University Cafeteria Safety Based on Pathfinder Simulation

  • Zechen Zhang;Jaewook Lee;Hasung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.209-217
    • /
    • 2024
  • Recent years have seen a notable increase in fire incidents in university cafeterias, yet the social attention to these occurrences remains limited. Despite quick responses to these incidents preventing loss of life, the need for large-scale evacuation in such high foot traffic areas can cause significant disruptions, economic losses, and panic among students. The potential for stampedes and unpredictable damage during inadequate evacuations underscores the importance of fire safety and evacuation research in these settings. Previous studies have explored evacuation models in various university environments, emphasizing the influence of environmental conditions, personal characteristics, and behavioral patterns on evacuation efficiency. However, research specifically focusing on university cafeterias is scarce. This paper addresses this gap by employing Pathfinder software to analyze fire spread and evacuation safety in a university cafeteria. Pathfinder, an advanced emergency evacuation assessment system, offers realistic 3D simulations, crucial for intuitive and scientific evacuation analysis. The studied cafeteria, encompassing three floors and various functional areas, often exceeds a capacity of 1500 people, primarily students, during peak times. The study includes constructing a model of the cafeteria in Pathfinder and analyzing evacuation scenarios under different fire outbreak conditions on each floor. The paper sets standard safe evacuation criteria (ASET > RSET) and formulates three distinct evacuation scenarios, considering different fire outbreak locations and initial evacuation times on each floor. The simulation results reveal the impact of the fire's location and the evacuation preparation time on the overall evacuation process, highlighting that fires on higher floors or longer evacuation preparation times tend to reduce overall evacuation time.In conclusion, the study emphasizes a multifaceted approach to improve evacuation safety and efficiency in educational settings. Recommendations include expanding staircase widths, optimizing evacuation routes, conducting regular drills, strengthening command during evacuations, and upgrading emergency facilities. The use of information and communication technology for managing emergencies is also suggested. These measures collectively form a comprehensive framework for ensuring safety in educational institutions during fire emergencies.

Operation Room Fire: Caution for Using Electrocautery after Rinsing Operation Field at the End of the Surgery with Alcohol-Based Cleansing Solutions (수술방 화재: 수술 종료 시 알코올 함유 피부 소독액을 이용한 수술부위 세척 이후 전기소작기 사용 주의)

  • Song, Jong Keun;Shin, Hyojeong;Lee, Jun Yong
    • Journal of the Korean Burn Society
    • /
    • v.22 no.2
    • /
    • pp.34-37
    • /
    • 2019
  • Fires in operating rooms rarely occur. However, this type of disaster can complicate almost any surgical procedure. Fuel, heat and oxygen are related with fire outbreak. When ignition sources such as alcohol-based surgical preparation solutions are present, the risk of an operating room fire increases, and burns are more severe in such conditions. Many manufacturers recommend waiting at least three minutes after application to allow complete drying for reduce fire risk. There are a few studies regarding flame burns in the operation room, although most of these studies are related to preoperative skin preparation. However, alcohol containing solutions can be used occasionally for cleansing of the operation field after the surgery, therefore, the surgical team should pay attention to surgical fires, even if they have completed the operation successfully. We present our case of a post-operative flame burn and introduce some precautions that will reduce the risk of alcohol burns.

The Impact of the Government's Earthquake Disaster Response Capabilities and the Legal and Institutional Appropriateness of the Disaster Management System on the Operational Performance of Disaster Management : Focused on Fire Officer's Consciousness (정부의 지진재난 대응역량과 재난관리체계의 법·제도적 적절성이 재난관리 운영성과에 미치는 영향 : 소방공무원의 인식을 중심으로)

  • Youn, SeokMin
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.318-330
    • /
    • 2020
  • Purpose: In this study, the effect of the government's disaster response capabilities and the legal and institutional appropriateness of the disaster management system on the operational performance of disaster management performance were verified. Method: Questionnaire survey was performed for the fire officials, and the surveyed data was statistically analyzed by using SPSS 25.0 program. Result: The main results of this study are as follows. First, the government's earthquake disaster response capability is found to have a significant effect on disaster follow-up management as well as disaster prevention preparation, which is a factor in disaster management performance. Second, it has been shown that the legal and institutional appropriateness of the earthquake disaster management system has a significant impact on disaster follow-up management as well as disaster prevention preparation, which is a factor of disaster management performance. Conclusion: The important policy implications for improving the operation performance of disaster management could be obtained in preparation for earthquakes in Korea.

A Study on escape using elevators in fire emergency (화재 시 승강기를 이용한 피난에 관한 연구)

  • Chung, Eui-Soo
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2007.11a
    • /
    • pp.55-68
    • /
    • 2007
  • Because of not accepted on escape using elevators in fire emergency has some background. In the background elevator hoistway has turn into smoke spread route in fire. The escape that used an elevator was not able to make ends meet; of the big confusion is expected that cannot control the escape adequately, and do that elevator facilities breakdown possibility by the fire water, the escaper shut in car. Therefore ban on elevator service in fire time as a general rule. Recently, a few company promote super high-rise architecture in the country, a fire disaster prevention and human life safety measures preparation for PBD(A Performance Based Fire Protection Design) are studied concretely. And there is the escape example in fire time that used an elevator in the foreign country. You must promote it so that the escape measures that used enclosed stairway and an elevator in charge of a function of the mutual supplement. The result of this research can be used for establishing the standard and regulation for using elevators in fire emergency.

  • PDF

A Study on the Major Standards and Actual Conditions of Evacuation Safety in Child Care Facility (보육시설의 피난안전 관련 주요 기준 분석 및 실태조사에 관한 연구)

  • Park, Jae-Sung
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.93-102
    • /
    • 2009
  • Recently, the number of child care facility and social demand for high quality child care service increase suddenly. Especially, social atmosphere about fire safety is more sensitive in Korea. The majority of the residents in a child care facility are composed of early childhood having difficulty to evacuate, and therefore the number of stories of a building and the appropriateness of a evacuation equipment play an important role in the evacuation safety. In this study, problems and improvements for the evacuation safety are dealt with the present conditions of child care facilities, the comparative analysis between domestic and foreign standards, the research on the actual condition of evacuation equipments, and so on. The study brings to a conclusion that it is necessary to systematize the regulations regarding fire safety, to connect fire-fighting facilities for design standards and operations of emergency preparation equipments, to improve the regulations for fire protection system such as the sprinkler system, and to restrict the facilities having fire hazards.