• Title/Summary/Keyword: Field Experimental Design

Search Result 1,255, Processing Time 0.036 seconds

Basic Features and Facts of Herbicide Evaluation for Efficacy and Phytotoxicity in Korea (제초제의 효능과 약해 평가상의 당면과제)

  • Yong-Woong Kwon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.23 no.3
    • /
    • pp.19-30
    • /
    • 1978
  • Use of herbicides in Korean agriculture has increased rapidly in recent years accompanying with ever-increasing pressure of farm labor shortage. Herbicides occupied already the second place in the rank of pesticides consumption in 1977. The agricultural experiment stations have carried out over 50 trials of chemical weed control each year since 1968. These research works and registration trials contributed much to the present wide use of herbicides. The pesticide management act amended in 1977 requires reevaluation of pesticides for their efficacy every 5 year-term. However, the development of sound weed control program and recommendations has been hempered very much by the lack of qualified workers of weed control research in agricultural experiment stations and in the institute for pesticide registration trial. Critical review of the past research works on herbicide evaluation and the present status indicates strong need for 1) the characterization of the nature of local and national weed problem, 2) the improvement of ability of the staffs in charge of weed control research through appropriate training on the basics and experimental techniques, and 3) organization and activities of weed control research committee. Furthermore, the present article attempts to clarify commonly misled points in the establishment of herbicide evaluation plan, in the design and execution of field trials, and in the assessment of trial results of the past works from the viewpoint of the basic principles with some case studies for resolution of specific enigmas.

  • PDF

Hybrid Rubber Mount by Using Magnetic Force (자력을 이용한 하이브리드 고무 마운트)

  • Ahn, Young Kong;Kim, Dong-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.3
    • /
    • pp.236-246
    • /
    • 2014
  • This paper presents a hybrid rubber mount with magnet to isolate effectively the vibration in vehicle, forklift, and so on. The hybrid mount does not have any controller of the magnetic force. Dynamic stiffness of the mount is reduced by only magnetic suction according to the applied magnetic field and damping coefficient increased. Performance of conventional rubber mount with using electromagnet has been investigated by MTS Tester. The governing equation of the hybrid mount was derived and verified by comparison with experimental and theoretical results. The equation can be used practically and usefully in the design of the mount and analysis of the mounting system. The hybrid mount provides excellent performance in vibration isolation and its structure is very simpler than active with controller and a semi-active mount with a functional fluid. Furthermore, production cost of the mount using permanent magnets is very lower than that of the active mount with electromagnets. Therefore, commercial potential of the mount is very high.

A System Design and Implementation for Geotechnical Engineering Field Application of Drone (드론의 지반공학분야 활용을 위한 시스템 설계 및 구현)

  • Kim, Taesik;Jung, Jinman;Min, Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.3
    • /
    • pp.173-178
    • /
    • 2016
  • Many studies have been carried out on monitoring the target by cooperating a drone with remote sensors recently. This monitoring system uses static sensors to measure environmental data and drones to collect measured data. In geotechnical engineering, inspectors go around measuring the safety of construction site and it is impractical to compose a network among numerous sensors in terms of the cost efficiency. In this paper, we propose a data collection system based on interaction between a drone and a few sensors that are installed around the target structure for geotechnical projects. Through experimental results, we also verify the availability and the time and cost efficiency of the proposed system comparing with using inspectors.

A Study on the Sensor for Measuring the High Frequency Magnetic Fields (고주파자계측정용 센서에 관한 연구)

  • Lee, Bok-Hee;Jeong, Seung-Soo;Park, Hyung-Ki;Paek, Yong-Hyun;Yim, Dong-Mook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.114-117
    • /
    • 1992
  • This paper presents the design and calibration methods of self-integrated magnetic sensor. Also the distance response measurement of magnetic field produced a transient large current and the frequency response measurement are carried out As the integrating resistance increases. the sensitivity of the sensor is improved, but the decay time constant of response decreases, Also the experimental results are well agreed with the theoretical analysis of the equivalent circuit.

  • PDF

Prediction of Change in Equivalent Circuit Parameters of Transformer Winding Due to Axial Deformation using Sweep Frequency Response Analysis

  • Sathya, M. Arul;Usa, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.983-989
    • /
    • 2015
  • Power transformer is one of the major and key apparatus in electric power system. Monitoring and diagnosis of transformer fault is necessary for improving the life period of transformer. The failures caused by short circuits are one of the causes of transformer outages. The short circuit currents induce excessive forces in the transformer windings which result in winding deformation affecting the mechanical and electrical characteristics of the winding. In the present work, a transformer producing only the radial flux under short circuit is considered. The corresponding axial displacement profile of the windings is computed using Finite Element Method based transient structural analysis and thus obtained displacements are compared with the experimental result. The change in inter disc capacitance and mutual inductance of the deformed windings due to different short circuit currents are computed using Finite Element Method based field analyses and the corresponding Sweep Frequency Responses are computed using the modified electrical equivalent circuit. From the change in the first resonant frequency, the winding movement can be quantified which will be useful for estimating the mechanical withstand capability of the winding for different short circuit currents in the design stage itself.

Numerical analysis of steady and transient processes in a directional solidification system

  • Lin, Ting-Kang;Lin, Chung-Hao;Chen, Ching-Yao
    • Coupled systems mechanics
    • /
    • v.5 no.4
    • /
    • pp.341-353
    • /
    • 2016
  • Manufactures of multi-crystalline silicon ingots by means of the directional solidification system (DSS) is important to the solar photovoltaic (PV) cell industry. The quality of the ingots, including the grain size and morphology, is highly related to the shape of the crystal-melt interface during the crystal growth process. We performed numerical simulations to analyze the thermo-fluid field and the shape of the crystal-melt interface both for steady conditions and transient processes. The steady simulations are first validated and then applied to improve the hot zone design in the furnace. The numerical results reveal that, an additional guiding plate weakens the strength of vortex and improves the desired profile of the crystal-melt interface. Based on the steady solutions at an early stage, detailed transient processes of crystal growth can be simulated. Accuracy of the results is supported by comparing the evolutions of crystal heights with the experimental measurements. The excellent agreements demonstrate the applicability of the present numerical methods in simulating a practical and complex system of directional solidification system.

Plasma Leptin and Performance of Purebred and Backcrossed Hereford throughout Grazing and Feedlot Fattening

  • Vega, R.A.;Hidari, H.;Matsunaga, N.;Kuwayama, H.;Manalo, D.D.;Lee, H.G.;Hata, H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.7
    • /
    • pp.954-959
    • /
    • 2004
  • In a herd of 24 spring-born steers, plasma leptin and performance of selected purebred (n=5) and backcrossed Hereford (n=5) were compared in a year-round summer grazing and winter feedlot fattening. Bimonthly blood collection and body weight measurement were accomplished. The plasma samples were analyzed for leptin, insulin, total cholesterol, triglyceride, NEFA and glucose. The experimental design utilized one-way ANOVA with breed as the treatment. The purebred obtained higher plasma NEFA (p<0.001) compared to backcross, regardless of seasonal feeding systems (SFS). The backcross showed gradual increase and nonresponsiveness of plasma leptin to SFS. During summer grazing, attenuation of plasma leptin and sudden elevation when shifted to winter feedlot fattening were observed in purebred. Plasma leptin obtained linear relationship with body weight of purebred (r=0.53;p<0.001) and backcrossed Hereford (r=0.49; p<0.01). The purebred and backcrossed Hereford, when shifted to summer grazing, resulted to sustained and restricted daily gain, respectively. Therefore, cattle breeds of higher growth potential exhibit significant elevation of plasma leptin after 400 kg BW, when animal starts to deposit significant body fat.

Design of Predistortion Linearizer using Common-Gate MESFET (공통 게이트 MESFET를 이용한 전치왜곡 선형화기 설계)

  • 주성남;박청룡;최조천;최충현;김갑기
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.53-56
    • /
    • 2003
  • A linear power amplifier is particularly emphasized on the CDMA system using a linear modulation scheme, because IMD which cause adjacent channel interference and co channel Interference is mostly generated in a nonlinear power amplifier. In this paper, a new type of linearization technique proposed. It is presented that balanced MESFET predistortion linearizer added. Experimental result are present for Korea PCS frequency band. The implemented linearizer is applied to a 30dBm class. A power amplifier for simulation performance. Two-tone signals at 1850 MHz and 1851.23 MHz are injected into the main power amplifier. The main power amplifier with a 12.1dB gain and a P1dB of 30 dBm(two-tone) was utlized. The reduction of IMD is around 22dB.

  • PDF

Gyroscopic Stability and Drag Characteristics Study of Canard-Installed Course Correction Munition (조종날개가 장착된 탄도수정탄의 자이로안정성 및 항력 특성 연구)

  • Bae, Ju Hyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.376-383
    • /
    • 2017
  • This paper describes the gyroscopic stability and the drag characteristics of the smart munition with a course correction fuze(CCF). A ballistic analysis was conducted to figure out the effect of the canards on the gyroscopic stability of the projectile. The analysis used the commercial ammunition performance evaluation software: Projectile Design and Analysis System(PRODAS). In particular, we compared the PRODAS analysis results to real field test results to investigate the influence of the CCF mounted projectile. In addition, some ballistic simulations were carried out to provide the conditions suitable for wind tunnel tests. Experimental results show that the added drag force by the canards is almost uniform regardless of the Mach number when the projectile is at the normal position where the angle of rotation and the angle of attack are both 0 degrees. However, as the angle of attack of the projectile increases, the additional drag force depends on the deflection of the canards.

A Study of rotor-stator interaction in an axial fan (축류송풍기의 동익과 정익 사이 간격변화에 따른 유동간섭에 관한 연구)

  • Rim, In-Won;Seon, Ho-Su;Joo, Won-Gu;Cho, Kang-Rae
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.819-824
    • /
    • 2000
  • The flow inside an axial turbomachinery must be unsteady. Rotor-stator interaction by two blade rows influences performance, the generation of noise and vibration. So, it will be necessary to study the rotor-stator interaction for the design of an axial fan in which the axial gap between two blade rows is small. In this study, rotor-stator interaction is investigated by experimental methods. The research fan has one stage which consists of 24 rotor blades and 22 stator blades. Three-dimensional velocities measured using $45^{\circ}$ slanted hot wire probe and total pressure is measured using Kiel total pressure probe between rotor and stator with the axial 25%, 55%, 145% of chord length,. This study describes the influence of rotor-stator gap on the flow pattern, performance and loss. The efficiency curve show that the change of the rotor-stator gap make difference in the efficiency. And, the 3-dimensional velocity distribution show that the potential interaction between the rotor and the stator have a great effect on the flow field downstream of rotor, where there are wake flow. various vortices in hub region and leakage vortex in casing region etc.

  • PDF