• Title/Summary/Keyword: Electronic monitoring

Search Result 1,283, Processing Time 0.033 seconds

REAL-TIME MONITORING TECHNOLOGY OF RAILWAY ELECTRIFICATION SYSTEM (철도시스템 전기설비의 실시간 모니터링 기술)

  • Park, Young;Jung, Ho-Sung;Kim, Hyung-Chul;Jeong, Kyu-Won;Park, Ki-Yub
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.476-477
    • /
    • 2007
  • The development of real-time monitoring technology provides reliable, timely information of railway maintenance and play a important role in determining the conditions of railway electrification system. Image motoring and wireless communication systems are currently used as remote transducer for real-time monitering. In this paper, we describe a real-time monitoring technology of railway electrification system based on the concept of high-voltage application, using the image processing and telemetry system methodology. the system and its performance for especially with regard to real-time monitering and railway electrification maintenance.

  • PDF

The Development of Network-based Telemetry System for Railway Catenary Inspection (전차선로 검측을 위한 네트워크 기반 델레메트리 시스템 개발)

  • Na, Hae-Kyung;Park, Young;Cho, Yong-Hyeon;Park, Hyun-Jun;Choi, Won-Seok;Kim, Eung-Kwon;Song, Joon-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.478-479
    • /
    • 2007
  • With increasing interest in the reduction of cost for operation and maintenance of overhead catenary system, various methods of condition monitoring have been developed. In this paper, we proposed network-based telemetry system for condition monitoring in railway and acquired data from any kind of sensor in catenary line and structure at high voltage. This development gives the solution for online condition monitoring in railway. To check the validity of our approach in terms of application, we realized network-based telemetry System.

  • PDF

Improved Self Plasma-Optical Emission Spectroscopy for In-situ Plasma Process Monitoring (실시간 플라즈마공정 모니터링을 위한 Self Plasma-Optical Emission Spectroscopy 성능 향상)

  • Jo, Kyung Jae;Hong, Sang Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.2
    • /
    • pp.75-78
    • /
    • 2017
  • We reports improved monitoring performance of Self plasma-optical emission spectroscopy (SP-OES) by augmenting a by-pass tube to a conventional straight (or single) tube type self plasma reactor. SP-OES has been used as a tool for the monitoring of plasma chemistry indirectly in plasma process system. The benefits of SP-OES are low cost and easy installation, but some semiconductor industries who adopted commercialized SP-OES product experiencing less sensitivity and slow sensor response. OH out-gas chemistry monitoring was performed to have a direct comparison of a conventional single type tube and a by-pass type tube, and fluid dynamic simulation on the improved hardware design was also followed. It is observed faster pumping out of OH from the chamber in the by-pass type SP-OES.

  • PDF

Development of a Smart Grid Monitoring System with Anti-Islanding Function for Electric Vehicle Charging (안티아일랜딩 기능을 적용한 전기자동차 충전계통 연계 스마트그리드 모니터링 시스템 개발)

  • Ro, Sunny;Shin, Bum-Sik;Lee, Kyung-Jung;Ki, Young-Hun;Ahn, Hyun-Sik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.31-37
    • /
    • 2012
  • In this paper, we present a smart grid monitoring system connected with electric vehicle charging system using anti-islanding method. Electric vehicles can be charged through remote control of smart grid monitoring system and the charging process may be more stable and more efficient by wireless communication between the Local Area Module and End Modules. It is illustrated by some experiments that electric vehicle charging process may not be interrupted without any serious fault even though the islanding phenomena occurred in the grid if the presented monitoring system was applied to the smart grid system.

Development of Humidity Sensor Based on Ceramic/Metal Halide Composite Films for Non-Contact Biological Signal Monitoring Applications (비접촉 생체신호 모니터링 응용을 위한 세라믹/메탈 할라이드 복합막 기반 습도센서 개발)

  • Park, Tae-Ung;Kim, Ik-Soo;Kim, Min-Ji;Park, Chulhwan;Seo, Eui-kyoung;Oh, Jong-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.4
    • /
    • pp.412-417
    • /
    • 2022
  • Capacitive-type humidity sensors with a high sensitivity and fast response/recovery times have attracted a great attention in non-contact respiration biological signal monitoring applications. However, complicated fabrication processes involving high-temperature heat treatment for the hygroscopic film is essential in the conventional ceramic-based humidity sensors. In this study, a non-toxic ceramic/metal halide (BaTiO3(BT)/NaCl) humidity sensor was prepared at room temperature using a solvent-free aerosol deposition process (AD) without any additional process. Currently prepared BT/NaCl humidity sensor shows an excellent sensitivity (245 pF/RH%) and superior response/recovery times (3s/4s) due to the NaCl ionization effect resulting in an immense interfacial polarization. Furthermore, the non-contact respiration signal variation using the BT/NaCl sensor was determined to be over 700% by maintaining the distance of 20 cm between the individual and the sensor. Through the AD-fabricated sensor in this study, we expect to develop a non-contact biological signal monitoring system that can be applied to various fields such as respiratory disease detection and management, infant respiratory signal observation, and touchless skin moisture sensing button.

PMD Effect on the Clock-based Optimum Dispersion Compensation Monitoring Technique

  • Kim, Sung-Man
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.112-115
    • /
    • 2009
  • We investigate the effect of polarization-mode dispersion (PMD) on the optimum dispersion compensation (ODC) monitoring and nonlinear penalty in optical transmission systems. We report that PMD may reduce the fiber nonlinearity. We also report that the monitoring error of the clock-based ODC monitoring technique decreases after the first-order PMD compensation. A simple explanation of this phenomenon is shown.

Experimental Demonstration and Analytic Derivation of Chromatic Dispersion Monitoring Technique Based on Clock-frequency Component

  • Kim, Sung-Man
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.215-220
    • /
    • 2012
  • In an earlier work, we proposed the chromatic dispersion monitoring technique of non-return to zero (NRZ) signal based on clock-frequency component (CFC) through numerical simulations. However, we have not yet shown any experimental demonstration or analytic derivation of it. In this paper, we show an experimental demonstration and analytic derivation of the proposed chromatic dispersion monitoring technique. We confirm that the experimental results and the analytic results correspond with the simulation results. We also demonstrate that monitoring range and accuracy can be improved by using a simple clock-extraction method.

Actinometric Investigation of In-Situ Optical Emission Spectroscopy Data in SiO2 Plasma Etch

  • Kim, Boom-Soo;Hong, Sang-Jeen
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.3
    • /
    • pp.139-143
    • /
    • 2012
  • Optical emission spectroscopy (OES) is often used for real-time analysis of the plasma processes. OES has been suggested as a primary plasma process monitoring tool. It has the advantage of non-invasive in-situ monitoring capability but selecting the proper wavelengths for the analysis of OES data generally relies on empirically established methods. In this paper, we propose a practical method for the selection of OES wavelength peaks for the analysis of plasma etch process and this is done by investigating reactants and by-product gas species that reside in the plasma etch chamber. Wavelength selection criteria are based on the standard deviation and correlation coefficients. Moreover, chemical actinometry is employed for the normalization of the selected wavelengths. We also present the importance of chemical actinometry of OES data for quantitative analysis of plasma. Then, the suggested OES peak selection method is employed.. This method is used to find out the reason behind abnormal etching of PR erosion during a series of $SiO_2$ etch processes using the same recipe. From the experimental verification, we convinced that OES is not only capable for real-time detection of abnormal plasma process but it is also useful for the analysis of suspicious plasma behavior.

Design and Implementation of Stand-alone Microgrid Monitoring System for Green Energy Independence Island (그린에너지 자립섬을 위한 계통 독립형 마이크로그리드 모니터링 시스템 설계 및 구현)

  • Song, Hwa-Jung;Park, Kyoung-Wook;Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.4
    • /
    • pp.527-532
    • /
    • 2015
  • In domestic island regions, the power supply generally depends on diesel generators due to difficulties of grid connection. To solve this issue, recently, the study on the stand-alone microgrid technology and its test are being actively conducted. In this paper, we propose the stand-alone microgrid integration monitoring system for energy independence island. First, we design the software architecture for monitoring of solar, wind, diesel power generation facilities, transmission and distribution of grid network, and energy storage system. Then, we implement the monitoring software that allows administrators to identify and run the monitoring software easily.

The Embedded Remote Monitoring Diagnosis for Integration Vessel System (디지털 선박 추진 시스템을 위한 임베디드 원격 모니터링 진단)

  • Park, Se-Hyun;Noh, Seok-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.11
    • /
    • pp.2708-2716
    • /
    • 2013
  • This paper presents implementation of embedded remote monitoring diagnosis system which has effective wireless channel structure and communication protocols with user-friendly UI for intelligent digital vessel. Developed system contains integrated vessel monitoring system, server, exclusive mobile terminal and smart phone. We designed an effective dual structure communication channel and simple but effective communication protocol on the monitoring system. Failures of the wireless communication are minimized and the wrong wireless communication channel is immediately replaced. In addition, we developed an effective embedded Linux UI for LCD. The implemented wireless monitoring system was tested and verified on digital vessel.