• Title/Summary/Keyword: Electrochemical immunoassay

Search Result 17, Processing Time 0.016 seconds

The Coordination of Pyridyl-N to Pentacyanoferrate for the Electrochemical Detecting Small Organic Molecules

  • Choi, Young-Bong;Jeon, Won-Yong;Kim, Hyug-Han
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.2
    • /
    • pp.595-599
    • /
    • 2013
  • The coordination of pyridyl-N to pentacyanoferrate for the detection of small organic antigens in solution is presented. The unique contribution of this paper is the direct conjugation of pyridyl-N in small organic antigens to pentacyanoferrate. Pentacyanoferrate is promising as an electrochemical label owing to its good electro-chemical properties, which can be utilized to generate an electrical signal in homogeneous electrochemical immunoassays. The facilely synthesized pyridyl-N to pentacyanoferrate was characterized by the electrochemical and spectroscopic methods. Hippuric acid (HA) has been detected competitively on the interaction of free HA and pentacyanoferrate-(4-aminomethylpyridine-hippuric acid) (Fe-HA) to its antibody, with the detection limit of 0.50 ${\mu}g\;mL^{-1}$. While pentacyanoferrate-based immunoassay is in its simplicity and infancy, the proposed immunoassay offers attractive opportunities for developing pyridyl-N-based the electrochemical detection of small organic antigens in the health care area.

Electrochemical Immunoassay based on the Dopamine-antigen Conjugate for Detecting Hippuric Acid (항원인 마뇨산에 결합된 도파민을 이용한 전기화학적 면역 분석법)

  • Choi, Young-Bong;Jeon, Won-Yong;Kim, Hyug-Han
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.3
    • /
    • pp.172-178
    • /
    • 2014
  • In this work, we describe an electrochemical immunosensor for simple, fast and quantitative detection of a urinary hippuric acid (HA). Urinary HA, of molecular weight 180 DA, is one of the major metabolites and biological indicators in toluene-exposed humans. Simple and ubiquitous monitoring of exposure to toluene is very important in occupational health care. We propose the electrochemical immunoassay based on the dopamine-antigen conjugate for detecting hippuric acid. Our electrochemical immunoassay system employs a conjugate of dopamine (DA) as an electrochemical active molecule and hippuric acid (HA) as an antigen. As an electrochemical aspect, dopamine (DA) containing two hydroxyl group can show excellent redox signal. Also, dopamine-tethered hippuric acid (DA-HA) shows the reversible redox signal in the immunoassay. The competition between HA and DA-HA generated electric signals proportional to HA concentration. The electrochemical immunoassay was performed with DA-HA on the screen printed carbon electrodes (SPCEs), and then applies the mixture antigen (HA) and HA-antibody. The electrical signals were proportional to HA in the range of 0.010~2.500 mg/mL which is enough range to be used for the point-of-care.

Electrochemical Immunoassay for Detecting Hippuric Acid Based on the Interaction of Osmium-Antigen Conjugate Films with Antibody on Screen Printed Carbon Electrodes

  • Choi, Young-Bong;Jeon, Won-Yong;Kim, Hyug-Han
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.5
    • /
    • pp.1485-1490
    • /
    • 2012
  • An electrochemical immunoassay based on osmium-hippuric acid (HA) conjugate films onto the electrode is presented for the detection of urinary HA. This is the first report on the use of the oxidative electropolymerization of 5-amino-1,10-phenanthroline (5-$NH_2$-phen) for immobilizing an antigen, osmium-conjugated HA. As a redox mediator, [Os(5-amino-1,10-phenanthroline)$_2$(4-aminomethylpyridine-HA)Cl]$^{+/2+}$ (Os-phen-HA) was successfully synthesized and electropolymerized onto the screen-printed carbon electrodes (SPCEs). The interaction between osmium-HA conjugate films and antibody-HA ($anti$-HA) was performed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The electrical signals were linearly proportional to urinary HA in the range of 0.1-5.0 mg/mL, which is sufficient for use as an immunosensor using a cutoff concentration of 2.0 mg/mL in urine samples. The proposed electrochemical immunoassay method can be extended to various applications for detecting a wide range of different small antigens in the health care area.

Electrochemical Method for Detecting Hippuric Acid Using Osmium-antigen Conjugate on the Gold Nanoparticles Modified Screen-printed Carbon Electrodes

  • Choi, Young-Bong;Kim, Hyug-Han
    • Journal of Electrochemical Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.57-61
    • /
    • 2011
  • This paper describes an electrochemical immunoassay for simple, fast and quantitative detection of a urinary hippuric acid which is one of major biological indicator in toluene-exposed humans. The electrochemical system of immunoassay was based on the directly osmium complex conjugated with hippuric acid. With the competition between free hippuric acid (HA) and the osmium-hippuric acid conjugate (Os-HA) to bind with antibody hippuric acid (Anti-HA) coated onto gold nanoparticles, the electrical signals were proportional to urinary hippuric acid (HA) in the range of 0.01-5 mg/mL which is enough range to be used for in-field or point-of-care (POC) diagnosis. The proposed electrochemical method can be extended to the applications to detect a wide range of different small molecules in the field of health care.

Simple Electrochemical Immunosensor for the Determination of Rabbit IgG Using Osmium Redox Polymer Films

  • Choi, Young-Bong;Lee, Seung-Hwa;Tae, Gun-Sik
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.3
    • /
    • pp.229-232
    • /
    • 2007
  • An amperometric immunosensor for the determination of rabbit IgG is proposed. The immunoassay utilizes a screen-printed carbon electrode on which osmium redox polymer is electrodeposited. This immunoassay detects 0.1 ng/ml of rabbit IgG, which is ${\sim}10^2$ fold higher than the most sensitive enzyme amplified amperometric immunoassay. The assay utilizes a screen-printed carbon electrode which was pre-coated by a co-electrodeposited film of an electron conducting redox hydrogel and a rabbit IgG. The rabbit IgG in the electron conducting film conjugates captures, when present, the anti-rabbit IgG. The captured anti-rabbit-IgG is labeled with horseradish peroxidase (HRP) which catalyzes the two-electron reduction of $H_2O_2$ to water. Because the redox hydrogel electrically connects HRP reaction centers to the electrode, completion of the sandwich converts the film from non-electrocatalytic to electro-catalytic for the reduction of $H_2O_2$ to $H_2O$ when the electrode is poised at 200 mV vs. Ag/AgCl.

Simple Electrochemical Immunosensor for the Detection of Hippuric Acid on the Screen-printed Carbon Electrode Modified Gold Nanoparticles

  • Choi, Young-Bong;Tae, Gun-Sik
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.1
    • /
    • pp.44-49
    • /
    • 2011
  • This paper describes an electrochemical immunosensor for simple, fast and quantitative detection of a urinary hippuric acid which is one of major biological indicator in toluene-exposed humans. The feature of this electrochemical system for immunoassay of hippuric acid is based on the direct conjugation of ferrocene to a hippuric acid. With the competition between the ferrocene-hippuric acid complex and hippuric acid for binding to the anti-hippuric acid monoclonal antibody coated onto gold nanoparticles, the electrical signals are turned out to be proportional to urinary hippuric acid in the range of 0.01-10 mg/mL, which is enough to be used for the point-of-care. The proposed electrochemical method could extend its applications to detect a wide range of different small molecules of antigens in the health care area.

Integration of immunohistochemical reactions into Electrochemical and Optical Analyses of Biochips (면역 조직화학 반응이 통합된 바이오칩의 전기화학 및 광학적 분석)

  • Choi Hyoung Gil;Hong Eun Kyoung;Lee Seung-Won;Yoon Hyun C.
    • KSBB Journal
    • /
    • v.20 no.2 s.91
    • /
    • pp.123-128
    • /
    • 2005
  • We have addressed two important issues of immunosensing biochips, including the construction of antibody functionalized suface for efficient affinity reactions and the development of a signal registration strategy that converts biospecific reactions into highly quantifiable electrochemical and/or optical signals. The developed immunoassay reaction is an integrated version of enzyme-mediated immunoprecipitaion reaction, which is widely used in immunohistochemistry, and electrochemical signaling reaction. For the evaluation of analytical performance of fabricated immunosensing biochips, signaling for mouse IgG in antiserum was conducted. Applications of the developed strategy have been found for the evaluation of histology chemicals and for the signal amplification for array-type biochip analysis.

The Principles and Metrical Applications of Immunocsensors (면역센서의 원리와 의학적 응용)

  • 김의락;백세환
    • KSBB Journal
    • /
    • v.17 no.2
    • /
    • pp.121-136
    • /
    • 2002
  • Immunosensors are of great interest because of their potential utility as specific, simple, label-free, direct detection means and provision of reduction in size, cost and time of analysis comparing with conventional immunoassay. In the last two decades, many reports have been published on the use of immunosensors for a wide range of applications to clinical diagnostics, pharmaceutical chemistry, environmental monitoring, biotechnology and food industries. There are also numerous transduction techniques developed such as electrochemical techniques, piezoelectric crystal, and surface plasmon resonance receiving much attention for the direct monitoring of immune reactions at solid surfaces. In this article, the principles, characteristics, structures, fonctions and clinical applications of immunosensors were reviewed