• Title/Summary/Keyword: Electrical wiring

Search Result 202, Processing Time 0.033 seconds

The structrue and wideband electrical characteristics of premises telecommunicatin wiring (구내통신의 배선구조와 광대역 전기적 특성)

  • 이강식;김창락;류명주;서태석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.9A
    • /
    • pp.2165-2172
    • /
    • 1998
  • Existing premises telecommucation wiring ad been installed for efficient telephone service. But premises wiring is currently ready to be reused as media for wideband digital services and Fiber-to-the-curb architecture. Electrical properties of premises wiring link have not characateized above frequencies for voice service. Accurte measurement of these characteristics are exssential for studies fof wideband ditital transmission system. On the other hand, the transmission qualities of premises wiring have been known to be worst in telecommunications access networks. So the knowledge of premises wiring sturucture as well as electrical properties is needed to improve the performance of premises wiring. In this paper, the structure of premises wiring is described in detail and electrical characteristics (characteristic impedance, SRL, attnuation, NEXT) about premises cables and stelecommucations link of representative apartment complex sare measured and naalyzed ove r16MHz range which is UTP Cat3 bandwidth.

  • PDF

An Experimental Study on Short Circuit Characteristics by the Interior Wiring Length (옥내배선 길이에 따른 단락 특성의 실험적 연구)

  • Song, J.Y.;Kim, J.P.;Cho, Y.J.;Choi, D.M.;Oh, B.Y.;Kil, G.S.
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.4
    • /
    • pp.38-42
    • /
    • 2012
  • This paper describes electrical fire on residential environment such as apartment and detached house caused by defect of interior wiring. We carried out experimental study on short circuit characteristics by the interior wiring length. We were measured arc current, arc energy and interrupting time of earth leakage current circuit breaker(ELB), when an interior wiring break out short circuit in residential environment. From the experiment results, the longer of the interior wiring, the magnitude of arc current decreased and the interrupting time of ELB increased. When applied the A maker's ELB, the strength of arc current and interrupting time of ELB was 254 A and 245 ms respectively at 30 m interior wiring length. In 3 m interior wiring length, arc current and interrupting time was 716 A and 4.24 ms respectively. Arc energy was dependent on the magnitude of arc current and the interrupting time of ELB, the longer the interrupting time, arc energy increasing. In this paper, minimum arc energy was 277 J using C maker's ELB and 3 m interior wiring length(arc current 283 A, interrupting time of breaker 6.28 ms). Therefore in the residential environment, short circuit caused by defect of the interior wiring lead to electrical fire.

A Study on the Establishment of Preventive Measures for Electric Fires Using the 4M Technique (4M 기법을 활용한 전기화재 예방대책 수립 연구)

  • Oh, Teakhum;Park, Chanseok
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.4
    • /
    • pp.23-29
    • /
    • 2021
  • The purpose of this study is to reduce the probability of occurrence of electric fires as a preemptive preventive measure, and to strengthen the capability of preventing electric fires by strengthening the cooperative function between electric fire-related departments and establishing a cooperative system. In this study, the general aspects of electric fires were identified by reviewing the literature such as ignition mechanisms of electric fires. And the major electrical fires that occurred in the last 10 years were classified into ignition factors (short circuit, overload/overcurrent, and earth leakage/ground fault) and ignition sources (wiring/wiring appliances, electrical equipment/household appliances). And the 4M technique was used to analyze the potential causes of ignition at the fire site and to suggest preventive measures. In the case In this study, out of 48 electrical fires in the past 10 years, 16 short-circuit fires, 3 overload/overcurrent fires, 3 short-circuit and earth fault fires, 16 fires in wiring/wiring appliances, and 10 fires in electrical equipment/home appliances classified as cases. And prevention measures were presented in terms of human, machine, media, and management by using the 4M technique. For the preemptive prevention of electric fires, strengthening the compulsory electrical safety inspection and making it mandatory to report when new or expanding electric facilities, charging a fee for electric safety inspection for detached houses and granting benefits subject to inspection completion, improvement of the electric safety voluntary inspection table and safety indications; It was suggested as a policy to organize and operate electrical safety inspection personnel in a two-person team (mixed), establish a close work cooperation system with related organizations, and strengthen electrical safety education and publicity.

A Study on Implementation for the PCB Design Simulator (PCB 디자인 시뮬레이터 구현에 관한 연구)

  • 김현호;우경환;이천희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.296-296
    • /
    • 2000
  • This paper describes the features of a transmission line and a wiring, and a design rule based on a demanded condition for a wiring. Like as the simulation of a circuit, by tracking the wiring path among parts that are disposed on PCB, we analyze the feature of the corresponding wiring using the design formula and rule. We implement a signal integrity simulator, which is capable of electrical and electronic simulation for the feature of a wiring signal and the corresponding signal, and the results are demonstrated.

  • PDF

A Study on the Fire Risk of Black Box Wiring in Motor Vehicle (자동차의 블랙박스 와이어링 화재 위험성에 관한 연구)

  • Kang, Sin-Dong;Kim, Ju-Hee;Choi, Jun-Pyo;Kim, Jae-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.22-28
    • /
    • 2017
  • According to the National Fire Data System (NFDS), more than 5,000 vehicle fires have occurred every year for the last 10 years. Vehicle fires are primarily caused by mechanical (breaking system and engine), electrical (wiring and battery), and chemical (oil and fuel gas leakage) problems. The electrical factor has increased with the installation of driver convenience equipment. For example, today, the black box is widely used to provide video data recording of motor vehicle accidents. The black box consists of a front camera, rear camera, and wires. The black box wires are directly connected to the junction box or fuse box from the start battery that operates to provide normal on power supplying for engine stop. It is extremely dangerous when the wires short circuit due to insulation aging, mechanical and electrical stress, etc. In this study, the black box wiring fire risk have been analyzed and investigated when the steady state and abnormal operations, and under the following conditions: wiring arrangements with a high temperature condition, insulation aging, poor contact, and short circuits. The results showed that black box wiring short circuits had a higher fire risk than the other fire hazard elements. To prevent fire hazards caused by black box wiring, the black boxes must be installed by qualified service personnel. Do not modify the wiring, remove the fuse and secure the wiring using cable ties or insulation tape.

A Study on The Effect of Power conversion system for De-wiring Trolley wire by Electric Railway System (전기철도 전차선 이선이 전력변환장치에 미치는 영향 연구)

  • Shin, Seung-Chul;Kim, Jae-Chul;Han, Seong-Ho;Lee, Su-Gil
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.381-383
    • /
    • 2006
  • A de-wiring trolley wire usually makes the electrical system complex and may have an adverse effect on the electrical system inside the train. It is important to analyze the effect on trains in de-wiring trolley wire. we accomplished an equivalent model of the electric train system. We used PSCAD/EMTDC, an electromagnetic transient program. The result of this study can be used as a facility design to use a power conversion system filter and needs to prove through actual field data in the main circuit of an electric train for a precise analysis about effect of de-wiring.

  • PDF

Extraction of Series Arc Signals Based on Wavelet Transform in an Indoor Wiring System

  • Ji, Hong-Keun;Cho, Young-Jin;Wang, Guoming;Hwang, Seong-Cheol;Kil, Gyung-Suk
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.4
    • /
    • pp.221-224
    • /
    • 2017
  • This paper dealt with the extraction of series arc signals based on wavelet transform in order to improve the accuracy of arc detection in indoor wiring systems. Three types of arc sources including a cord-cord, a terminal-cord, and an outlet-plug were fabricated to simulate typical arc defects. An arc generator fabricated according to UL 1699 was used to generate arcs. The optimal mother wavelet was selected as bior1.5 by calculating the correlation coefficients between the detected single current pulse and the wavelet. The detected arc current signals were then decomposed into eight levels using the discrete wavelet transform that implements the multi-resolution analysis method. By analyzing the decomposed components, the detail components D6, D7, and D8 were associated with arc signals, which were used for signal reconstruction. From the result, it was verified that the proposed method can be used for the extraction of the series arc signal from the AC mains, which is expected to be applied to further analysis of arc signals in indoor wiring systems.

The Role of a Wiring Model in Switching Cell Transients: the PiN Diode Turn-off Case

  • Jedidi, Atef;Garrab, Hatem;Morel, Herve;Besbes, Kamel
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.561-569
    • /
    • 2017
  • Power converter design requires simulation accuracy. In addition to the requirement of accurate models of power semiconductor devices, this paper highlights the role of considering a very good description of the converter circuit layout for an accurate simulation of its electrical behavior. This paper considers a simple experimental circuit including one switching cell where a MOSFET transistor controls the diode under test. The turn-off transients of the diode are captured, over which the circuit wiring has a major influence. This paper investigates the necessity for accurate modeling of the experimental test circuit wiring and the MOSFET transistor. It shows that a simple wiring inductance as the circuit wiring representation is insufficient. An adequate model and identification of the model parameters are then discussed. Results are validated through experimental and simulation results.

A Study on the Wiring Plan Considering Construction and Frame Performance Degradation of BIPV System (BIPV시스템 시공 및 프레임 성능저하를 고려한 배선처리방안 제시에 관한 연구)

  • Oh, Min-Seok;Kim, Gi-Cheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.4
    • /
    • pp.33-42
    • /
    • 2018
  • In the application of the BIPV system, it is expected that the workability is lowered due to the difficulty in securing the space for wiring in the frame and the performance of the frame due to the wiring hole processing is lowered. Therefore, In this study, we propose a method to improve the wiring of the inner space of the BIPV frame, and through the simulation evaluation process, the thermal and condensation performance are secured by complementing the problems caused by the hole machining, and the time and effort required for BIPV construction are reduced. For this purpose, a wiring treatment method using a flange insertion tube was proposed, and the thermal and condensation performance was evaluated through simulation analysis.

Development of the High-Reliability PLC-CAN Communication Module for Construction Equipment (건설 중장비용 고신뢰성 PLC-CAN 통신 모듈 개발)

  • Ku, Ja-Yl;Jang, Se-Bong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.228-234
    • /
    • 2014
  • In the case of construction equipment, internal wiring has a very complicated structure such as an electrical wiring and hydraulic equipments. Because of these complex wiring, a lot of time is spent on maintenance and equipment manufacturing. In this paper, we design and implementation of the high-reliability PLC(Power Line Communication) -CAN(Controller Area Network) communication module to reduce electrical wiring of the construction equipment.