This paper describes electrical fire on residential environment such as apartment and detached house caused by defect of interior wiring. We carried out experimental study on short circuit characteristics by the interior wiring length. We were measured arc current, arc energy and interrupting time of earth leakage current circuit breaker(ELB), when an interior wiring break out short circuit in residential environment. From the experiment results, the longer of the interior wiring, the magnitude of arc current decreased and the interrupting time of ELB increased. When applied the A maker's ELB, the strength of arc current and interrupting time of ELB was 254 A and 245 ms respectively at 30 m interior wiring length. In 3 m interior wiring length, arc current and interrupting time was 716 A and 4.24 ms respectively. Arc energy was dependent on the magnitude of arc current and the interrupting time of ELB, the longer the interrupting time, arc energy increasing. In this paper, minimum arc energy was 277 J using C maker's ELB and 3 m interior wiring length(arc current 283 A, interrupting time of breaker 6.28 ms). Therefore in the residential environment, short circuit caused by defect of the interior wiring lead to electrical fire.

Keywords

References

  1. 소방방재청, 국가화재정보센터, http://www.nfds.go.kr
  2. W. F. Cooper, Electrical Safety Engineering, pp. 250-257, 3th Edition, 1993.
  3. A. A. Hattangadi, Electrical Fires and Failures, pp. 24-60, Mcgraw-Hill, 2000.
  4. 원종수, "전기화재-전기기기의 출화요인과 감식", 한국화재소방학회논문지, Vol. 2, No. 2, pp. 51-58, 1988.
  5. Tammy Gammon, John Matthews, "Arcing-Fault Models for Low-Voltage Power System", IEEE, pp, 119-126, 2000.
  6. 길경석, 지홍근, 박대원, 김일권, 김영일, 조영진, "병렬아크의 고속 차단에 관한 연구", 한국조명전기설비학회 논문지, Vol. 22, No. 12, pp. 95-100, 2008.
  7. 이상호, 오홍석, "전기화재예방을 위한 EFPCD 동작 특성에 관한 연구", 한국화재소방학회논문지, Vol. 12, No. 3, pp. 3-11, 2002.