• 제목/요약/키워드: Electrical input impedance

검색결과 232건 처리시간 0.027초

전력선 통신에서의 전자파 장해에 관한 연구 (A Study of Electromagnetic Interference in Power Line Communication)

  • 이진택;천동완;박영진;이원태;신철재
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권12호
    • /
    • pp.620-625
    • /
    • 2004
  • In this paper, we studied the emissive electric field due to the communication signal and the noise in medium voltage power-line. There are many types of conductive noise in power-line channel, which gives rise to radiation. And if the DMT carrier signal was excited, the current by this term was added to the current by noise and, generate radiation. We calculated input impedance by means of signal input network model of medium voltage power-line channel for calculating these currents. We calculated currents by input impedance and, calculated the emissive electric field by this calculated currents. From the measurement results, we knew that the measured results are very similar to the calculated results and if the input signal power level was higher than -40 dBm, the emissive electric field exceeds FCC radiation limit level 69.5 dB$\mu$V/m.

손실성 물질 근접 시 안테나 성능변화 (Antenna Performance Variation near a Lossy Material)

  • 이재원;위상혁;김영수;양훈기;육종관
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.353-356
    • /
    • 2005
  • There have been many researches on the antenna performance degradation with the presence of the human body around the antenna structure to accomodate personal communication service [1][2]. To better understand the human body effects on the antenna resonance, radiation pattern, and input impedance, simulation was carried out with changing of the distance between antenna and lossy material. Effects on the antenna performance by the surrounding materials are also important in the case of the RFID system. It is desirable that the tag antennas for RFID system must reveal isotropic radiation pattern as well as attain the good impedance matching. In this paper, we investigated the antenna resonance and input impedance characteristic when there exist a lossy material sphere near various types of antenna at 900 MHz. In short antenna resonance was mostly affected by lossy material in the case of a rectangular loop antenna, and impedance variation was smallest in the case of a halfwave dipole.

  • PDF

생체임피던스 측정을 위한 새로운 부트스트래핑 회로와 전송선로 모델링 (New bootstrapping circuit and transmission line modeling for bioimpedance measurement)

  • 김영필;권석영;황인덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 A
    • /
    • pp.179-182
    • /
    • 2003
  • A simulation on bootstrapping circuit has been performed by modelling a coaxial cable as a transmission line. It is shown that the bootstrapping circuit could be unstable due to the transmission line effect though an ideal amplifier is used. While the conventional bootstrapping circuit does not cancel the input capacitance of the input buffer, a new bootstrapping circuit that cancels input capacitance of the input buffer has been proposed. The proposed bootstrapping circuit consists of the input buffer of which gam is larger than 1 and a feedback resistor to control the loop gain. The proposed bootstrapping circuit has higher input impedance than that of the conventional circuit.

  • PDF

유비쿼터스 헬스 케어 적용을 위한 의자 부착형 무선 심전도 측정 시스템 구현 (Implementation of Wireless ECG Measurement System Attaching in Chair for Ubiquitous Health Care Environment)

  • 예수영;백승완;김지철;전계록
    • 한국전기전자재료학회논문지
    • /
    • 제21권8호
    • /
    • pp.776-781
    • /
    • 2008
  • In this study, ubiquitous health care system attaching in chair to monitor ECG for health care was developed at the unconsciousness state. The system conveniently and simple measured ECG at non-consciousness. We measured the contact impedance to skin-electrode of metal mesh electrodes of the system. Contact impedance enable the electrode to use for ECG measurement. The results are that the impedance of the metal mesh electrodes according to sizes is low when the size is 4$cm^2$. As the result, when the size of the metal mesh electrode is 4$cm^2$, the electrode is fit for ECG measurement. We can acquired by positing the arm on the metal mesh electrode. The ECG signal was detected using a high-input-impedance bio-amplifier, and then passed filter circuitry. The measured signal transmitted to a PC through the bluetooth wireless communication and monitored. Data of the non-constrained ECG system attaching in chair is noise-data when comparing metal mesh electrode with the Ag/Agcl electrode but the data is significant to monitor ECG for check the body state.

Three Dimensional Finite Element Analysis for Piezoelectric Transformer

  • Joo, Hyun-Woo;Lee, Chang-Hwan;Jung, Hyun-Kyo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권3호
    • /
    • pp.98-103
    • /
    • 2001
  • This paper presents the numerical analysis of piezoelectric devices using three-dimensional finite element analysis. The characteristic of piezoelectric transducer, such as mechanical displacement and electrical are analyzed and the validity is confirmed by experiments Applying the finite element routine to a piezoelectric transformer, the resonance features electrical impedance. the ratio of step-up voltage and vibration mode of piezoelectric transformer are calculated numerically By using three-dimensional finite element method effects of width variation to resonance features, electrical input impedance and the voltage step-up ratio for a piezoelectric transformer, can be considered in design procedure.

범용 임피던스 변환회로를 이용한 압전 단결정 진동자의 제동용량 제어 (Clamped capacitance control of a piezoelectric single crystal vibrator using a generalized impedance converter circuit)

  • 김정순;김무준
    • 한국음향학회지
    • /
    • 제37권1호
    • /
    • pp.46-52
    • /
    • 2018
  • 압전변압기에 사용되는 압전 단결정은 높은 입력 임피던스로 인하여 파워전송용량이 높지 않다는 문제점이 있다. 따라서 본 연구에서는 연산증폭기를 사용한 범용 임피던스 변환(General Impedance Convert, GIC) 회로로 구현된 정전용량 증가회로를 압전 단결정 진동자의 전기단자에 연결함으로써 입력임피던스를 저하시켜 파워전송용량을 향상시킬 수 있는 방법을 제안하였다. $128^{\circ}$회전 Y판 $LiNbO_3$ 단결정 진동자에 설계 제작된 정전용량 증가회로를 적용하여 구동 특성을 측정한 결과, 입력임피턴스는 25 % 감소, 전기-기계결합계수는 30 % 증가, 전압변환 특성에 있어서는 약 17~30배의 출력파워용량이 증가됨을 확인하였다.

Input Impedance and Current Feedforward Control of Single-Phase Boost PFC Converters

  • Park, Sungmin;Park, Sung-Yeul;Bazzi, Ali M.
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.577-586
    • /
    • 2015
  • The combination of voltage feedforward and feedback control is a conventional approach for correcting the power factor in single-phase ac-dc boost converters. The feedback duty ratio increases significantly with an increase of the line frequency and input inductance. Therefore, the performance of the conventional approach is highly dependent on the bandwidth of the feedback controller. As a result, the input power quality can be significantly exacerbated due to uncompensated duty ratios if the feedback controller is limited. This paper proposes an input impedance and current feedforward control method to reduce the control portion of the feedback controller. The findings in this paper are 1) the theoretical derivation and analysis of variations of line frequency and input inductance on a power factor correction approach, 2) guaranteed consistent performance in a wide range of conditions, and 3) that a low switching frequency can be utilized by the proposed method. A MATLAB/Simulink model and a 1.2kW dual boost converter are built to demonstrate the effectiveness of the proposed method.

Adjustable-Performace, Single-Ended Input Double-Balanced Mixer

  • Choi, Jin-Yong;Lee, Kyung-Ho;Lee, Sang-Gug
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제1권4호
    • /
    • pp.248-252
    • /
    • 2001
  • A noble single-ended input, double-balanced mixer topology is proposed. The mixer incorporates the common-source amplifier input stage with inductive degeneration for impedance matching. The analysis based on simulations shows that the overall performance of the mixer is excellent and is adjustable by varying the input transistor size to give best characteristics for the given linearity specifications.

  • PDF

구형 도파관 벽면에 뚫은 반파장 스롯트 안테나의 복사모양과 임피단스 (The Characteristics of Impedance and Radiation Patterns of Half Wave Slot Antenna on the Wide Surface of Rectangular Wave Guide)

  • 양인응;박평길
    • 전기의세계
    • /
    • 제14권1호
    • /
    • pp.26-34
    • /
    • 1965
  • The radiation patterns and impedance of the half wave solt on the wide side of rectangular wave guide are analyzed. The measuring methods and procedures are described. And that the experimental data of the pattern and impedance of the slot are presented which are consistent with the theoretical values. The causes of error are also considered and are believed to be tolerable for the pattern and input impedance measurements. The usefulness of the slot antenna tested are also described.

  • PDF

급격히 꺾인 Taper를 갖는 Traveling-wave Coplanar Waveguide형 $LiNbO_34$전기광학변조기 전송선로의 전기적 특성 (Electrical Properties of Traveling-wave Coplanar Waveguide Transmission Line with a Abruptly broken Input-Output-taper for $LiNbO_3$Optical Modulator Electrode)

  • 정운조;김성구
    • 한국전기전자재료학회논문지
    • /
    • 제13권12호
    • /
    • pp.1051-1057
    • /
    • 2000
  • A traveling-wave CPW(coplanar waveguide) electrode with abruptly broken input/output-taper for LiNbO$_3$optical modulator was designed and fabricated. The electrical characteristics of traveling-wave electrode on z-cut LiNbO$_3$crystal with SiO$_2$buffer layers were measured by network analyzer. To confirm the possibility of the electro-optic modulator electrode, detailed calculations of the impedance, microwave effective index and attenuation constants are presented as a function of the microwave electrode thickness, but the buffer layer thickness is fixed as 1${\mu}{\textrm}{m}$. These characteristics are discussed from the viewpoint of the device optimization and are expected to be design guides for the LiNbO$_3$modulator’s electrodes.

  • PDF