• Title/Summary/Keyword: Electric probe

Search Result 230, Processing Time 0.026 seconds

Development of API module program for automatic tool compensation on machining center (머시닝센터의 자동공구보정을 위한 API모듈용 프로그램개발)

  • 정상화;신현성;김현욱
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.100-105
    • /
    • 2002
  • In general, manufacturing error originated in bad material, machine tool defection, tool defection, and tool breakage. When the manufacturing process is stable, the error is come from the tool wear. In common on-machine measurement, teaching probe and touch sensor are widely used, however in this thesis the automatic tool compensation system using electric touch point measuring system is developed and evaluated, and effective operating is proposed.

  • PDF

Development and Evaluation of Automatic Tool Compensation System (공구감시 시스템의 보정장치 개발과 평가에 관한 연구)

  • 정상화;신현성;차경래
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.5
    • /
    • pp.93-99
    • /
    • 2002
  • In general, manufacturing error is originated from bad material, machine tool defection and tool breakage. When the manufacturing process is stable, the most of error come from the tool wear. In common on-machine measurement teaching probe and touch sensor are widely used however in this paper the electric touch point type automatic tool compensation system is developed the performance of it is validated and effective operating is proposed.

RF Compatibility Test Results of COMS satellite with Launch Vehicle (천리안위성의 발사체와의 전자파 적합성 시험결과 분석)

  • CHOI, Jae-Dong
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.215-217
    • /
    • 2010
  • This paper describes the test results of radiated compatibility with Ariane 5 launcher performed on the COMS Satellite test facility. Firstly, the Radiated Emission test results are analyzed in compliance with the Radiated Susceptibility requirement specification of Ariane 5 launcher. The satellite nominal operation is monitored during injection a radiated electric field corresponding to the launcher emissions levels in critical frequency ranges. And also, E-field are measured through a probe located at external units level in order to assess the EMC safety margin in Radiated mode.

  • PDF

Temperature-compensated Resistivity Probe - Development and Application (온도보상형 전기비저항 프로브 - 개발 및 적용)

  • Jung, Soon-Hyuck;Yoon, Hyung-Koo;Lee, Jong-Sub
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.1
    • /
    • pp.51-60
    • /
    • 2011
  • Electrical resistivity is applied for understanding details about layers and obtaining basic properties of soils to various measurement devices. The objective of this study is development of TRP(Temperature-compensated Resistivity Probe), analysis about effects of temperature changes during cone penetration test, and observation of characteristics of cone penetration. In order to observation of temperature changes according to a diameter difference of resistivity cone probe, the cone which has wedge type cone tip is made to two types, 2mm and 5mm. Temperature sensor is attached at 15mm below from cone tip because of an electrical interference with elecrical resistance probe. Delectrical connector is used to prevent electric disturbance between motor type penetrating machine and electrical resistivity cone probe. Application tests are carried out in acrylic cell whose diameter is 30cm with uniform Jumunjin sand according to densification caused by blows. The test results indicate that the temperature is increased uniformly during penetration and a tendency, characteristics of cone penetration, is discovered during altering state of soils. This study suggests that the temperature effects and characteristics of penetration should be considered in penetrating tests in order to conduct an accurate ground investigation using TRP(Temperature-compensated Resistivity Probe).

A study on the Lubricational Characteristics Line Contact Frictional Mechanism (선접촉 마찰기구를 이용한 윤활특성에 관한 연구)

  • Chi, Chang-Heon;Lee, Chong-Soon;Rhee, Bong-Goo
    • Tribology and Lubricants
    • /
    • v.3 no.1
    • /
    • pp.47-51
    • /
    • 1987
  • The purpose of this paper is to study the lubrication characteristics which is occured in contact surface of two meterials. In this study, experimental apparatus which was modelling of the Cold rolling was used. Electric resistance, the temperature variation and the friction coefficient, between Disk and Roller were measured by respectively electric circuit system, temperature probe, and strain gauge. The experiment carried on the disk velocity range of 10m/min to 1000m/min in loading weight 2kg to 18kg.

Visible Light Spectrum of H2 Plasma Generated a Commercial Electric Power in the Parallel Plate Reactor (상용전원 평행판전극 방전장치에서 수소플라스마의 가시광선스펙트럼)

  • Choi, Woon Sang;Ji, Taek Sang;Kang, Sung Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.15-20
    • /
    • 1999
  • Visible light spectrum emitted from $H_2$ plasma in the parallel plate reactor using a commercial electric power are investigated by optical emission spectroscopy. Intensity of visible light is measured as a function of $H_2$ pressure and discharging power, and the intensity is compared with plasma density measured with the probe. As a result, the intensity is affected by plasma density and the plasma density is controlled the $H_2$ pressure and the discharging power.

  • PDF

Analysis of Electrical Property on Inductively Coupled Ar Plasma for Gas Pressure (유도결합형 Ar 플라즈마의 압력에 따른 전기적 특성분석)

  • 조주웅;이영환;김광수;허인성;최용성;박대희
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.3
    • /
    • pp.133-136
    • /
    • 2004
  • Low-Pressure inductively coupled RF discharge sources have important industrial applications mainly because they can provide a high-density electrodeless plasma source with low ion energy and low power loss. In an inductive discharge, the RF power is coupled to the plasma by an electromagnetic interaction with the current flowing in a coil. In this paper, the experiments have been focussed on the electric characteristic and carried out using a single Langmuir probe. The internal electric characteristics of inductively coupled Ar RF discharge at 13.56(MHz) have been measured over a wide range of power at gas pressure ranging from 1∼70(mTorr).

A Study on Measurement for Endmill Dia. using Electric Contact Method (공구마모보정을 위한 전기접점식 자동공구 보정시스템 개발)

  • 정상화;신형성;나윤철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.445-449
    • /
    • 2001
  • The tool wear that is developed by long-term machining in mold manufacturing with machining center makes a severe influence to the accuracy and the surface roughness. In this reason, tool-wear supervising system which has guaranteed high accuracy and high speed is needed to improve the measurement quality. Touching probe and touch sensor are widely used to measure the tool profile at on-machine measurement. In this paper, using the newly developed electric touch point measuring system, the Automatic Tool Compensation System is developed to correct the error of tool diameter resulted from the wear, and the operating method of this system is also provided.

  • PDF

Ar Gas properties of Inductively Coupled Plasma for Input Power (유도결합형 플라즈마에서 압력에 따른 Ar Gas의 특성분석)

  • Jo, Ju-Ung;Lee, Y.H.;Her, In-Sung;Kim, Kwang-Soo;Choi, Yong-Sung;Lee, Jong-Chan;Park, Dea-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1704-1706
    • /
    • 2003
  • Low-Pressure inductively coupled RF discharge sources have important industrial applications mainly because they can provide a high-density electrodeless plasma source with low ion energy and low power loss. In an inductive discharge, the RF power is coupled to the plasma by an electromagnetic interaction with the current flowing in a coil. In this paper, the experiments have been focussed on the electric characteristic and carried out using a single Langmuir probe. The internal electric characteristics of inductively coupled Ar RF discharge at 13.56 [MHz] have been measured over a wide range of power at gas pressure ranging from $1{\sim}70$ [mTorr].

  • PDF

A novel preparation of polyaniline in presence electric and magnetic fields

  • Hosseini, Seyed Hossein;Gohari, S. Jamal
    • Advances in materials Research
    • /
    • v.2 no.4
    • /
    • pp.209-219
    • /
    • 2013
  • We have described primary studies on conductivity and molecular weight of polyaniline separately in the electric and magnetic fields when it is used in a field effect experimental configuration. We report further studies on doped in-situ deposited polyaniline. First we have chemically synthesized polyaniline by ammonium peroxodisulfate in acidic aques and organic solutions at different times. Then we measured mass and conductivity and obtained the best time of polymerizations. In continue, we repeated these reactions separately under different electric and magnetic fields in constant time and measured mass and conductivity. The polyaniline is characterized by gel permeation chromatography (GPC), UV-Visible spectroscopy and electrical conductivity. High molecular weight polyanilines are synthesized under electric field, $M_w$ = 520000-680000 g/mol, with $M_w/M_n$ = 2-2.5. The UV-Visible spectra of polyanilines oxidized by ammonium peroxodisulfate and protonated with dodecylbenzenesulfonic acid (PANi-DBSA), in N-methylpyrolidone (NMP), show a smeared polaron peak shifted into the visible. Electrical conductivity of polyanilines has been studied by four-probe method. The conductivity of the films of emeraldine protonated by DBSA cast from NMP are higher than 500 and 25 S/cm under 10 KV/m of potential) electric field and 0.1 T magnetic field, respectively. It shows an enhanced resistance to ageing too. By the next steps, we carried chemical polymerization at the best electric and magnetic fields at different times. Finally, resulted in finding the best time and amount of the fields. The longer polymerization time and the higher magnetic field can lead to degradation of polyaniline films and decrease conductivity and molecular mass.