• 제목/요약/키워드: Electric Pole

검색결과 249건 처리시간 0.028초

동계 배전부하 특성분석 (An Analysis on the Winter Season's Distribution Load Characteristics)

  • 박창호;조성수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.935-938
    • /
    • 1998
  • This paper presents the method of load management to measure the winter season's load characteristics of distribution pole transformers. The proposed load model constructed used by the quadratic load correlation coefficients. To verify the estimated model, we compared with linear model by calculation results. The results can contribute an improvement of conventional load management method.

  • PDF

EMTDC로 구현한 제주-해남 HVDC 시스템의 사고모의 및 AC Protection (Fault Simulation and AC side Protection of Cheju-Haenam HVDC using EMTDC)

  • 박상호;전영수;김수열;임성주;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.372-374
    • /
    • 2002
  • 제주-해남 HVDC 시스템의 #1, #2 Pole이 동시 운전 중에 동기조상기가 탈락할 경우, HVDC시스템의 운전모드 절체와 제주기력 #2, #3호기의 출력변화 등을 EMTDC 프로그램으로 시뮬레이션 하였다. 또한 HVDC 시스템의 AC측 보호계전기를 계전 알고리즘을 이용하여 EMTDC 모델로 구현하고 제주 교류계통에서 사고 발생시 HVDC 시스템의 보호를 검토하였다.

  • PDF

전력자동화서비스를 위한 광네트워크 설계 및 모뎀개발 (The Development of the Optical Network for the Automation Systems in Electric Power Companies)

  • 김명수;현덕화;조선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2543-2545
    • /
    • 2002
  • There are many applicable services such as remote metering, load control, distribution line automation, Pole transformer Monitoring having their own networks in the electric power company. The application of the optical network technology as the back-born network to the Automation Systems in KEPCO is potentially beneficial in reliability, speed, and expandability. The 1-core and 2-core optical modems were developed and used by the Distribution Automation System. But, They had some disadvantages and advantages. So, We designed the new optical modems applied each advantages. This paper presents some of design efforts and test results for the multi-channel optical modem at KRPRI.

  • PDF

기초근가와 기존근가의 하중에 따른 변위 비교분석 (A Comparative Analysis of Displacement Measurement of the Earth Surface by Load for Root Anchor Block and Rectangle Anchor Block)

  • 문성원;김점식;김도영;박용범
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.863-869
    • /
    • 2013
  • In this paper, we compared and analyzed for safety 1.2m rectangular anchor block and arch-type root anchor block. First, numerical analysis was performed three-dimensional nonlinear method by numerical model test using finite element analysis program "Visual FEA". Then, measure displacement of the surface of the earth after construct each anchor block at 14M electric pole and increase loads through field verification tests for safety evaluation.

General Characteristic of Fractional Slot Double Layer Concentrated Winding Synchronous Machine

  • Seo, Un-Jae;Chun, Yon-Do;Choi, Jae-Hak;Chung, Shi-Uk;Han, Pil-Wan;Koo, Dae-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.282-287
    • /
    • 2013
  • The concentrated winding configurations offer significant advantage for reducing end windings. These machines are generally used in low speed high torque application due to relatively low copper loss. However, numbers of fractional slot construction make the designer hard to properly choose pole and slot numbers for the certain application. This paper provides the general information of possible fractional slot concentrated double layer winding machine.

주상변압기 부하 상관식 조정에 관한 실증적 연구 (Practical Study on Adjustment of Load Correlation Equations of Pole Transformer)

  • 박창호;김두봉;김기현;배주천;윤상윤;김재철
    • 조명전기설비학회논문지
    • /
    • 제14권1호
    • /
    • pp.102-108
    • /
    • 2000
  • 본 논문은 주상변압기의 부하관리를 위한 부하 상관식 조정에 관한 실증적 연구 결과를 제시하였다. 부하 상관식 조정을 위하여 주상 변압기의 사용전력량[kWh]과 최대 부하[A] 사이의 상관 관계를 분석하였다. 또한 상관식의 정확성을 높이기 위하여 12개의 지역 패턴으로 분류하였다. 그리고 각 지역 패턴에 24개씩의 표본 주상 변압기를 선정하였다. 부하 상관식에 사용된 데이터의 신뢰성을 위하여 표본 주상변압기에 부하관리기를 설치하였다. 온-라인 데이터 취득을 통하여, 데이터 베이스를 구축하였다. 부하 상관식 조정에 있어서 본 논문에서는 두 부분에 대해 고려를 하였다. 그중 하나는 부하 상관식의 적합성 또 하나는 과부하로 인한 주상변압기 손실 방지이다. 최종적으로 1, 2차 상관함수를 병용하는 상관식올 제안하였다. 또한 사례 연구를 통하여 제안한 부하 상관식이 기존에 사용하는 상관식 보다 오차 비율이 감소했음을 입증하였다.

  • PDF

Design and Realization of a Digital PV Simulator with a Push-Pull Forward Circuit

  • Zhang, Jike;Wang, Shengtie;Wang, Zhihe;Tian, Lixin
    • Journal of Power Electronics
    • /
    • 제14권3호
    • /
    • pp.444-457
    • /
    • 2014
  • This paper presents the design and realization of a digital PV simulator with a Push-Pull Forward (PPF) circuit based on the principle of modular hardware and configurable software. A PPF circuit is chosen as the main circuit to restrain the magnetic biasing of the core for a DC-DC converter and to reduce the spike of the turn-off voltage across every switch. Control and I/O interface based on a personal computer (PC) and multifunction data acquisition card, can conveniently achieve the data acquisition and configuration of the control algorithm and interface due to the abundant software resources of computers. In addition, the control program developed in Matlab/Simulink can conveniently construct and adjust both the models and parameters. It can also run in real-time under the external mode of Simulink by loading the modules of the Real-Time Windows Target. The mathematic models of the Push-Pull Forward circuit and the digital PV simulator are established in this paper by the state-space averaging method. The pole-zero cancellation technique is employed and then its controller parameters are systematically designed based on the performance analysis of the root loci of the closed current loop with $k_i$ and $R_L$ as variables. A fuzzy PI controller based on the Takagi-Sugeno fuzzy model is applied to regulate the controller parameters self-adaptively according to the change of $R_L$ and the operating point of the PV simulator to match the controller parameters with $R_L$. The stationary and dynamic performances of the PV simulator are tested by experiments, and the experimental results show that the PV simulator has the merits of a wide effective working range, high steady-state accuracy and good dynamic performances.

거푸집 설치 방법에 따른 철도 전철주기초의 모멘트 저항 거동 (Moment Resisting Behaviors of Railway Electric Pole Foundation According to Form Work Methods)

  • 이수형;이승현
    • 한국산학기술학회논문지
    • /
    • 제14권1호
    • /
    • pp.411-417
    • /
    • 2013
  • 철도선로에 설치되는 전철주기초의 모멘트에 대한 거동을 파악하기 위한 실물 재하시험을 수행하였다. 현장타설방식으로 설치된 폭 1.1m, 깊이 2.2m의 정사각형 전철주기초 2본에 대하여 실제 조건과 동일한 모멘트 위주의 하중을 가하여 기초의 항복모멘트를 확인하였다. 거푸집 설치 여부가 기초의 저항모멘트에 미치는 영향을 평가하기 위하여 동일한 조건에서 거푸집을 설치한 경우와 그렇지 않은 경우에 대하여 시험하였다. 거푸집 설치 효과로 흙과 지반의 접촉면이 매끈해지면서 발생하는 마찰력 감소보다는, 거푸집 미설치 시 굴착지반의 이완에 의한 기초 주변지반의 강도 감소 효과가 더 크게 나타나는 것으로 나타났다. 비례계수를 사용하여 포괄적으로 전철주기초의 저항모멘트를 산정하는 현행 설계방법으로는 거푸집의 설치효과를 적절히 고려할 수 없었으며, 연직응력과 마찰력을 분리하여 저항모멘트를 산정하는 경우에는 기초와 지반의 마찰각을 20% 감소시킴으로써 거푸집 설치효과에 대한 합리적인 고려가 가능하였다.

부하관리 개선을 위한 부하 상관계수 산정에 관한 연구 (Adjustment of load correlation coefficient for advanced load management)

  • 박창호;조성수;김기현;임진순;김두봉;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1267-1269
    • /
    • 1999
  • This paper studies on arrangement of load correlation coefficient for advanced load management. To accurate load correlation coefficient, we used two real factors, electrical energy(kWh) and peak load current of pole transformers, acquired by measuring instrument. Out of several correlation equations, we find that the quadratic equation is the most accurate to express peak load current and working electrical energy. If the data is located in the outside of ${\pm}3{\sigma}$ it is discarded. For load management, we rearranged load correlation coefficient considering +2${\sigma}$ at load correlation equation. Comparing conventional load correlation coefficient with rearranged one, we can get the result of error reduced and it is adjacent to the actual data. It will be used peak load forecasting from working electrical energy and we are able to prevent from the damaging of pole transformer due to overload.

  • PDF

Optimal Speed Control of Hybrid Electric Vehicles

  • Yadav, Anil Kumar;Gaur, Prerna;Jha, Shyama Kant;Gupta, J.R.P.;Mittal, A.P.
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.393-400
    • /
    • 2011
  • The main objective of this paper is to control the speed of Nonlinear Hybrid Electric Vehicle (HEV) by controlling the throttle position. Various control techniques such as well known Proportional-Integral-Derivative (PID) controller in conjunction with state feedback controller (SFC) such as Pole Placement Technique (PPT), Observer Based Controller (OBC) and Linear Quadratic Regulator (LQR) Controller are designed. Some Intelligent control techniques e.g. fuzzy logic PD, Fuzzy logic PI along with Adaptive Controller such as Self Organizing Controller (SOC) is also designed. The design objective in this research paper is to provide smooth throttle movement, zero steady-state speed error, and to maintain a Selected Vehicle (SV) speed. A comparative study is carried out in order to identify the superiority of optimal control technique so as to get improved fuel economy, reduced pollution, improved driving safety and reduced manufacturing costs.