In this paper, we compared and analyzed for safety 1.2m rectangular anchor block and arch-type root anchor block. First, numerical analysis was performed three-dimensional nonlinear method by numerical model test using finite element analysis program "Visual FEA". Then, measure displacement of the surface of the earth after construct each anchor block at 14M electric pole and increase loads through field verification tests for safety evaluation.

키워드

참고문헌

  1. Editorial department, "Design basis2", KEPCO, 2008
  2. KEOCO Distribution Line Automation, "Distribution Line Execution Standard", 2001. 6
  3. Braja, M. DAS, "Principles of Soil Mechanics", ELSEVIER, 2009
  4. M. J. Pender, "Aseismic pile foundation desing analysis", Bulletin of the Newzealand national society for earthe quake engineering. vol. 26, No, 1, Narch 1993
  5. Braja, M. DAS, "Principles of Geotechnical Engineering", ELSEVIER, 2012
  6. Seong-Yul Ahn, "Getting Started with finite element analysis by Visual FEA", SytecEnc, 2003. 8
  7. Jae-Young Lee, "Apply to finite element analysis by VISUAL FEA", Gunsulbook, 2006. 5
  8. Jeom-Sik Kim other 6, "The Construction Quailty Comparation and Analysis by Electric Poles Construction Method", Korean Institute of Illuminating and Electrical Installation Engineers Annual Fall Conference, pp.247-249, 2009
  9. Jeom-Sik Kim other 3, "A comparative analysis of stability by numerical models for arch-type root anchor block", Korean Institute of Illuminating and Electrical Installation Engineers Spring Annual Spring Conference, pp. 169-171. 2011
  10. Tae-Bong Ahn, "Lateral Displacement Analysis of Concrete Electric Pole Foundation Grounds", Journal of the Korean Illuminating and Electrical Installation Engineers Vol. 23, No.5, pp.42-49, May 2009 https://doi.org/10.5207/JIEIE.2009.23.5.042
  11. Tae-Bong Ahn, "Horizontal Stress Analysis of Electric Pole using Earth Pressure Cell from Mock-up Tension Test", Journal of the Korean Illuminating and Electrical Installation Engineers Vol.24, No.8, pp.62-69, 2010 https://doi.org/10.5207/JIEIE.2010.24.8.062
  12. Dong-Myung Kim, "Research of Stress Distribution and Loading Weight on Concrete Electric Pole Considering Field Condition", Journal of the Korean Illuminating and Electrical Installation Engineers Vol. 18, No.5, pp.183-188, September 2004