Abstract
The moment responses of electric pole foundations for a railroad were investigated using real-scale load tests. Large overturning moments were applied to two square rigid piles with a 1.1 m width and a 2.2 m embedded depth. Two different installation methods-with and without a form-were applied to evaluate the influence of the form work on the moment capacities of the foundations. The reduction of ground strength caused by the excavation without a form is more pronounce than the decrease of frictional strength due to the smooth concrete surface with a form. From the test results, it is found that the current design method which applies a proportional coefficient to consider the effect of a form work is not appropriate. When the normal and frictional stressed is considered separately, the effect of a form work can be estimated reasonably by reducing the friction angle between soil and foundation by 20%.
철도선로에 설치되는 전철주기초의 모멘트에 대한 거동을 파악하기 위한 실물 재하시험을 수행하였다. 현장타설방식으로 설치된 폭 1.1m, 깊이 2.2m의 정사각형 전철주기초 2본에 대하여 실제 조건과 동일한 모멘트 위주의 하중을 가하여 기초의 항복모멘트를 확인하였다. 거푸집 설치 여부가 기초의 저항모멘트에 미치는 영향을 평가하기 위하여 동일한 조건에서 거푸집을 설치한 경우와 그렇지 않은 경우에 대하여 시험하였다. 거푸집 설치 효과로 흙과 지반의 접촉면이 매끈해지면서 발생하는 마찰력 감소보다는, 거푸집 미설치 시 굴착지반의 이완에 의한 기초 주변지반의 강도 감소 효과가 더 크게 나타나는 것으로 나타났다. 비례계수를 사용하여 포괄적으로 전철주기초의 저항모멘트를 산정하는 현행 설계방법으로는 거푸집의 설치효과를 적절히 고려할 수 없었으며, 연직응력과 마찰력을 분리하여 저항모멘트를 산정하는 경우에는 기초와 지반의 마찰각을 20% 감소시킴으로써 거푸집 설치효과에 대한 합리적인 고려가 가능하였다.