• Title/Summary/Keyword: Drug-eluting stents

Search Result 36, Processing Time 0.02 seconds

Controlled Release of Paclitaxel from Biodegradable Polymer Films for Drug-Eluting Stents (약물방출 스텐트용 생분해성 고분자 필름으로부터 파크리탁셀의 조절 방출)

  • Kim, Si-Eun;Lee, Bong-Soo;Kim, Jin-Hyang;Park, Kwi-Deok;Han, Dong-Keun
    • Polymer(Korea)
    • /
    • v.34 no.2
    • /
    • pp.172-177
    • /
    • 2010
  • Although many researchers have studied the efficacy of paclitaxel (PTX) on many cells during the last two decades, little work has been reported on the importance of release kinetics inhibiting cell proliferation. The aim of this study is to examine the release behavior of the PTX on various biodegradable polymers such as poly(lactic-co-glycolic acid)(PLGA), poly-L-lactide (PLLA), and polycaprolactone (PCL) for drug-eluting stents (DES). The PTX from the fabricated films was released for 8 weeks and the degree of degradation of the films was observed by FE-SEM. Although the degradation time of PCL was the slowest, the PTX release rate was the fastest among them and followed by PLGA and PLLA with the equivalent PTX concentration. It suggests that hydrophobic drug such as PTX from polymer with low $T_g$ like PCL could be moved easily and released rapidly in body temperature.

Numerical Study of Flow Pattern and Drug Deposition in Drug-Eluting Stent (약물분출 스텐트 주위 유동형태와 약물침전에 대한 수치해석)

  • Seo, Tae-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.10
    • /
    • pp.1053-1060
    • /
    • 2011
  • This study is performed to determine the drug concentration profiles of drug-eluting stents (DES) for an ideal circular ring stent and intertwined stent models for various Reynolds numbers (Re = 200, 400, and 800). The Navier.Stokes equations coupled with the advection-diffusion equation are solved numerically in order to determine how the flow patterns and drug deposition are affected in the in-stent and post-stent regions where flow separation and recirculation occur. The presence of DES within the arterial segment affects the local drug distribution in the flow field. As a result, the drug concentration for the intertwined stent is higher over the in-stent region in comparison with the ideal stents. For a given stent geometry, the local drug concentration in the in-stent region decreases with Reynolds number, while for a given Reynolds number, the local drug concentration is relatively insensitive to the stent geometry. The results show that drug concentration along the arterial wall is significantly higher within the in-stent and post-stent regions for the intertwined stent geometry than for the ideal stent geometries.

A Novel Deposition Method of PLGA Nanoparticles on Coronary Stents

  • Joo, Jae-Ryang;Nam, Hye-Yeong;Nam, So-Hee;Baek, In-Su;Pakr, Jong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.1085-1087
    • /
    • 2009
  • Bare metal stents which were used to treat coronary artery disease have several biochemical problems. Polymerbased drug-eluting stents (DES) have opened up a new paradigm in the treatment of in-stent restenosis. Many studies and research programmes have proved that DES can prevent restenosis. In our study, paclitaxel-loaded poly (lactic-co-glycolic acid) (PLGA) nanoparticles have been deposited along the three dimensional scaffold of coronary stents by a method using self-assembling properties of colloidal particles. We found that the nanoparticles were deposited uniformly and closely packed. The amount of paclitaxel was easily controlled by the drug content of the nanoparticles and the deposition count.

Precise ultrasonic coating and controlled release of sirolimus with biodegradable polymers for drug-eluting stent

  • Joung, Yoon Ki;Jang, Bu Nam;Kang, Jong Hee;Han, Dong Keun
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.1 no.1
    • /
    • pp.13-25
    • /
    • 2014
  • In the current study, a drug-eluting stent coated with biodegradable polymers and sirolimus was developed by using an ultrasonic nanocoater and characterized in aspects of surface smoothness and coating thickness. In addition, in vitro release profiles of sirolimus by changing top coating layer with different biodegradable polymers were investigated. Smooth surfaces with variable thickness could be fabricated by optimizing polymer concentration, flow rate, nozzle-tip distance, gas pressure, various solvents and ultrasonic power. Smooth surface could be generated by using volatile solvents (acetone, chloroform, and methylene chloride) or post-treating with solvent vapor. Coating thickness could be controlled by varying injection volume or polymer concentration, and higher concentration could reduce the coating time while obtaining the same thickness. The thickness measurement was the most effectively performed by a conventional cutting method among three different methods that were investigated in this study. Release profiles of sirolimus were effectively controlled by changing polymers for top layer. PLGA made the release rate 3 times faster than PDLLA and PLLA and all top layers prevented burst release at the initial phase of profiles. Our results will provide useful and informative knowledge for developing drug-eluting stents, especially coated with biodegradable polymers.

Thermal Process for Enhancing Mechanical Strength of PLGA Nanoparticle Layers on Coronary Stents

  • Joo, Jae-Ryang;Nam, Hye-Yeong;Nam, So-Hee;Baek, In-Su;Park, Jong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.9
    • /
    • pp.1985-1988
    • /
    • 2009
  • Poly (lactic-co-glycolic acid) (PLGA) nanoparticles loading paclitaxel have been deposited on coronary stents by self-assembling properties of colloidal particles. The layers of the nanoparticles were enhanced to a sufficient mechanical strength by a thermal process under the proper temperature and humidity conditions. In vitro release studies proved the controlled paclitaxel release of the nanoparticle layers. This technique gives rise to a new range of applications for nanoparticles and drug-eluting stents.

Comparison between Basic and Inverse Dual Drug and Peptide-coated Stents in a Porcine Restenosis Model

  • Jang, Eun-Jae;Lee, So-Youn;Bae, In-Ho;Park, Dae Sung;Jeong, Myung Ho;Park, Jun-Kyu
    • Applied Chemistry for Engineering
    • /
    • v.31 no.5
    • /
    • pp.502-508
    • /
    • 2020
  • Dual drug-eluting stents (DES) is a primary treatment method for coronary arterial diseases in current interventional cardiology practice. However, their pathological results according to the sequence of coating of drugs have not been reported yet. The peptide-dopamine dissolved in acetonitrile was coated onto the Chonnam National University Hospital (CNUH) stent using an electrospinning coating machine. For secondary coating (e.g., sirolimus coating, designated as SPS), sirolimus (SRL) and poly lactic-glycolic acid (PLGA) were mixed in tetrahydrofuran (THF), and the solution was then coated on the CNUH stent that had underwent the primary peptide coating using an electrospinning and spray technique. Next, the peptide-dopamine was coated on the SRL-PLGA coated stent (PSS). In this study, it was confirmed that endothelialization was promoted without being significantly affected by the coating order (SPS or PSS). The sequence of drug and peptide coating may affect the development of restenosis and PSS was effective in the prevention of restenosis compared to that of using SPS.

Clinical Outcomes of Stent Thrombosis after Drug-Eluting Coronary Stent Implantation (약물방출 관상동맥 스텐트 시술 후 스텐트 혈전증 발생 환자의 임상경과)

  • Kim, In-Soo;Jeong, Myoung-Ho;Han, Jae-Bok;Jang, Young Ill;Jang, Seong-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.880-892
    • /
    • 2013
  • Stent thrombosis after successful drug-eluting stent(DES) implantation has been reported in around 1% of patients in clinical trials. However, the increased risk of ST associated with DES remains a matter of concern. From 1 June 2003 to 30 June 2013, we investigated clinical characteristics, in-hospital outcomes in 10,273 patients who underwent percutaneous coronary intervention in the Heart Center of CNUH. Overall incidence of ST was 1.30% (134 patients). The incidence of ST according to the stent generations and the timing of ST (n=total, early vs. late vs. very late) were 0.79% (n=81, 26 vs. 12 vs. 43) in first-generation, 0.38% (n=39, 21 vs. 9 vs. 9) in second-generation and 0.14% (n=14, 8 vs 3 vs. 3) in third-generation, (p=0.70). The mortality from ST was significantly higher in early ST group compared to the late and very late ST groups (18.2% vs. 8.3% vs. 3.6%, p=0.042). Overall incidence of ST after DES implantation was 1.30% (134 patients). The in-hospital mortality was significantly higher in early ST group compared to the late and very late ST groups.

Comparison of the One-year Follow-up Results after Coronary Bypass Surgery versus Percutaneous Coronary Intervention with Drug-eluting Stents in Patients with Left Main Coronary Artery Disease (좌주간지 병변에 대한 약물방출스텐트시술과 관상동맥우회수술의 1년 추적결과 비교)

  • Choi, Jin-Ho;Lim, Cheong;Park, Kay-Hyun;Chung, Eui-Suk;Chung, Woo-Young;Chae, In-Ho;Choi, Dong-Ju
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.210-215
    • /
    • 2008
  • Background: Drug-eluting stents are contributing to the exponential growth of percutaneous coronary intervention, and even in the patients with left main coronary artery disease, owing to the decreased restenosis rate. Our study aimed at comparing the one-year results after coronary artery bypass grafting versus percutaneous coronary intervention with drug-eluting stents in patients with left main coronary artery disease. Material and Method: Those patients who underwent coronary bypass surgery or stenting at our hospital under the diagnosis of left main coronary artery disease were divided in two groups. The variables for comparison were the preoperative disease severity, the length of the hospital stay, the early mortality and the cumulative incidence of mortality, myocardial infarction and repeated revascularization. Result: There were 101 cases in the surgery group and 78 cases in the stent group. Age, gender, the risk factors, the left ventricular ejection fraction and the proportion of acute coronary syndrome showed no significant differences between the two groups. The surgery group showed a more severe condition according to the Euroscore, a greater incidence of urgency, a longer hospital stay and a greater incidence of multi-vessel disease. The early mortality and one-year cumulative mortality were not different between the groups. The Euroscore-matched comparison for the surgery group (41 patients) and the stent group (78 patients) showed no significant differences in the Euroscore, age, gender, risk factors and the proportion of acute coronary syndrome. The surgery group in the Euroscore-matched comparison showed more multi-vessel disease and a longer hospital stay. The surgery group showed lower early mortality and lower one-year cumulative mortality, but this was statistically insignificant (0% vs 2.6%, respectively, p=0.55; 0% vs 6.6%, respectively, p=0.30). The rates of repeated revascularization and major adverse events (death or myocardial infarct) were lower in the CABG group, but this was not statistically significant (13.3% vs 6.3%, respectively, p=0.48; 10.0% vs 0%, respectively, p=0.09). Conclusion: Percutaneous coronary intervention using drug-eluting stents in low-risk patients with left main coronary artery disease resulted in a shortened length of the hospital stay, as compared with that of the CABG group of patients. However, the patients who underwent percutaneous coronary intervention using drug-eluting stents showed a tendency for an increased rate of repeated revascularization and higher one-year cumulative mortality. Further studies with large populations and longer follow-up will be necessary to reaffirm our findings.