• Title/Summary/Keyword: Drain engineering

Search Result 987, Processing Time 0.027 seconds

LNA Design Uses Active and Passive Biasing Circuit to Achieve Simultaneous Low Input VSWR and Low Noise (낮은 입력 정재파비와 잡음을 갖는 수동 및 능동 바이어스를 사용한 저잡음증폭기에 관한 연구)

  • Jeon, Joong-Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1263-1268
    • /
    • 2008
  • In this paper, the low noise power amplifier for GaAs FET ATF-10136 is designed and fabricated with active bias circuit and self bias circuit. To supply most suitable voltage and current, active bias circuit is designed. Active biasing offers the advantage that variations in the pinch-off voltage($V_p$) and saturated drain current($I_{DSS}$) will not necessitate a change in either the source or drain resistor value for a given bias condition. The active bias network automatically sets a gate-source voltage($V_{gs}$) for the desired drain voltage and drain current. Using resistive decoupling circuits, a signal at low frequency is dissipated by a resistor. This design method increases the stability of the LNA, suitable for input stage matching and gate source bias. The LNA is fabricated on FR-4 substrate with active and self bias circuit, and integrated in aluminum housing. As a results, the characteristics of the active and self bias circuit LNA implemented more than 13 dB and 14 dB in gain, lower than 1 dB and 1.1 dB in noise figure, 1.7 and 1.8 input VSWR at normalized frequency $1.4{\sim}1.6$, respectively.

An experimental study on the rating of noise emission from water supply and drain installations in apartment bathroom (공동주택 욕실 급배수음 평가방법 제정방안에 관한 실험적 연구)

  • Lee, Tai-Gang;Song, Min-Jeong;Jang, Gil-Soo;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.5-10
    • /
    • 2006
  • This study aims to propose appropriate evaluating method of noise emission from water supply and drain installations in apartment bathroom. Because KS(Korean Standard) about water installations noise in apartment bathroom only are establishing the measurement procedure of it, Evaluation and rating procedure is necessary to improve the sound insulation performance of the apartment and to reduce the apartment dweller's unsatisfaction with the noise. Thus, this study reviewed the standards and evaluating methods about the water supply and drain installations noise of many other country. We measured the noise emission from the installations in many apartment bathroom, and then we calculated the noises to dB(A), N, NC evaluated numbers. We analyze the coefficient of the corelation among the evaluated numbers to induce the appropriate method. As a result, the dB(A) method is most easy to evaluateing and very high corelated wth N and N index, So the dB(A) method is suitable to be adopted KS evaluating procedure of noise emission from water installations in apartment bathroom.

  • PDF

Breakdown Voltage and On-resistance Characteristics of N-channel EDMOS with Dual Work Function Gate (이중 일함수 구조를 적용한 N-채널 EDMOS 소자의 항복전압 및 온-저항 특성)

  • Kim, Min-Sun;Baek, Ki-Ju;Kim, Yeong-Seuk;Na, Kee-Yeol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.9
    • /
    • pp.671-676
    • /
    • 2012
  • In this paper, TCAD assessment of 30-V class n-channel EDMOS (extended drain metal-oxide-semiconductor) transistors with DWFG (dual work function gate) structure are described. Gate of the DWFG EDMOS transistor is composed of both p- and n-type doped region on source and drain side. Additionally, lengths of p- and n-type doped gate region are varied while keeping physical channel length. Two-dimensional device structures are generated trough TSUPREM-4 and their electrical characteristics are investigated with MEDICI. The DWFG EDMOS transistor shows improved electrical characteristics than conventional device - i.e. higher transconductance ($g_m$), better drain output current ($I_{ON}$), reduced specific on-resistances ($R_{ON}$) and higher breakdown characteristics ($BV_{DSS}$).

An Experimental Study on the Subjective Response for Water Supply and Drain Installations in Apartment Bathroom (공동주택 급배수 설비소음의 주관반응에 관한 실험적 연구)

  • Lee, Tai-Gang;Ko, Kwang-Pil;Kim, Hang;Song, Guk-Gon;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.6
    • /
    • pp.663-673
    • /
    • 2008
  • The purpose of this study is to analyze the appropriate evaluation method for the water supply and drain noise of bathroom in apartment and to propose some fundamental idea on its regulation. For this reason, it was studied the acoustical characteristics of water supply and drain noise as modifying the water supply pressure for the washbasins and toilet stools and suggested the optimum evaluation method through psychoacoustic test. As a result of investigation of the levels by evaluating the adjectives and noise sources with 7-step criteria corresponding to each level of plumbing noises and analysis of the correlation between physical evaluation values by comparing the criteria, dB(A), N, and NC, with subject's response, determination coefficient($R^2$) was shown to be relatively fair or higher ranged from 0.65 to 0.92. It is shown that 'Harsh', 'Nervous', 'Unpleasant', 'Distasteful', and 'Repellent' as a second factor are to be appropriate to evaluate plumbing noise. Above these results could be used in basic data establishing KS(Korean Standard) for evaluation and rating procedure and measures reducing these noise.

Analysis of Drain Induced Barrier Lowering for Double Gate MOSFET According to Channel Doping Concentration (채널도핑강도에 대한 이중게이트 MOSFET의 DIBL분석)

  • Jung, Hak-Kee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.3
    • /
    • pp.579-584
    • /
    • 2012
  • In this paper, drain induced barrier lowering(DIBL) has been analyzed as one of short channel effects occurred in double gate(DG) MOSFET. The DIBL is very important short channel effects as phenomenon that barrier height becomes lower since drain voltage influences on potential barrier of source in short channel. The analytical potential distribution of Poisson equation, validated in previous papers, has been used to analyze DIBL. Since Gaussian function been used as carrier distribution for solving Poisson's equation to obtain analytical solution of potential distribution, we expect our results using this model agree with experimental results. The change of DIBL has been investigated for device parameters such as channel thickness, oxide thickness and channel doping concentration.

Vibration Reducing Method for High Pressure Feedwater Heater Drain Piping System (고압급수가열기 배수계통 배관계 고진동 해소방안 연구)

  • Lee, Wook-Ryun;Lee, Jun-Shin;Kim, Sang-Bok;Hong, Soon-Bup;Shin, Yong-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1290-1295
    • /
    • 2006
  • The 120 meters high pressure feedwater heater drain piping in nuclear power plant had been suffered by excessive vibration from the beginning of power generation. As time goes by, the piping vibration was beyond the allowable limit and an appropriate countermeasure was required to prevent the fatigue failure of the pipeline from the abnormal vibration. In this study, the vibrational characteristics of high pressure feedwater heater drain piping and the countermeasure for abnormal vibration were investigated. Among the several vibration reduction methods, the piping layout changed by making the smooth pipeline was applied to the high Pressure feedwater heater drain piping in nuclear Power plant. Applying the countermeasure, the vibration level was found to reduce over 54 percents and was satisfied under the allowable velocity at the full-power operation condition.

  • PDF

Operation characteristics of IGZO thin-film transistors (IGZO 박막트랜지스터의 동작특성)

  • Lee, Ho-Nyeon;Kim, Hyung-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1592-1596
    • /
    • 2010
  • According to the increase of the channel length with fixed width/length, characteristic curves of drain current as a function of gate bias voltage of indium gallium zinc oxide (IGZO) thin-film transistors moved to a positive direction of gate voltage, and field-effect mobility decreased. In case of fixed length and width of channel, field-effect mobility was lower and subthreshold slope was larger when drain bias voltage was higher. Due to large work function of IGZO, band bending at the junction region between IGZO channel and source/drain electrodes was expected to be in opposite direction to that between silicon and metal electrodes; this could explain the above results.

An Experimental Study on the Noise Characteristics of Water Supply and Drain Installations Varied with Water Suppling Pressure in Apartment Bathroom (급수압 변화에 따른 대변기와 세면기의 급배수 소음 특성에 관한 실험적 연구)

  • Lee, Tai-Gang;Ko, Kwang-Pil;Choi, Eun-Suk;Kim, Hang;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.3 s.120
    • /
    • pp.226-234
    • /
    • 2007
  • This study aims to evaluate noise emission from water supply and drain installations in apartment bathroom. These noise were one of the most annoying noise sources in apartment houses. Especially, drain plumbing system have used bellow bathroom ceiling, it was very discomfort to hear the noise in bellow apartment. Noise of closets and faucets were measured which were main noise source, then these noise were evaluate and analyzed the emitting characteristics varying the supplying water pressure. As increasing the water pressure, also total noise level of the water supplying stool noise and faucet noise were increased. Especially the water closet showed remarkably the increasing noise level in middle and high frequency bandwidth, while the noise level of faucets increased in $50\;Hz{\sim}250\;Hz$ of low frequency bandwidth. Vortex closet were favorable to syphon closet, and lever faucet were favorable to conventional lavatory faucet on reducing the noise. Above these results could be used in basic data establishing KS (Korean Standard) for evaluation and rating procedure and measures reducing these noise.

UV Responsive Characteristics of n-Channel Schottky Barrier MOSFET with ITO as Source/Drain Contacts

  • Kim, Tae-Hyeon;Lee, Chang-Ju;Kim, Dong-Seok;Sung, Sang-Yun;Heo, Young-Woo;Lee, Jung-Hee;Hahm, Sung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.156-161
    • /
    • 2011
  • We fabricated a schottky barrier metal oxide semiconductor field effect transistor(SB-MOSFET) by applying indium-tin-oxide(ITO) to the source/drain on a highly resistive GaN layer grown on a silicon substrate. The MOSFET, with 10 ${\mu}M$ gate length and 100 ${\mu}M$ gate width, exhibits a threshold gate voltage of 2.7 V, and has a sub-threshold slope of 240 mV/dec taken from the $I_{DS}-V_{GS}$ characteristics at a low drain voltage of 0.05 V. The maximum drain current is 18 mA/mm and the maximum transconductance is 6 mS/mm at $V_{DS}$=3 V. We observed that the spectral photo-response characterization exhibits that the cutoff wavelength was 365 nm, and the UV/visible rejection ratio was about 130 at $V_{DS}$ = 5 V. The MOSFET-type UV detector using ITO, has a high UV photo-responsivity and so is highly applicable to the UV image sensors.

A Case Study on the Application of Gravel Pile in Soft Ground (Gravel Pile의 현장적용을 위한 시험시공 사례연구)

  • 천병식;고용일;여유현;김백영;최현석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.02a
    • /
    • pp.32-41
    • /
    • 2000
  • Sand drain as a vertical drainage is widely used in soft ground improvement Recently, sand, the principal source of sand drain, is running out. The laboratory model tests were carried out to utilize gravel as a substitute for sand. Though which the characteristics of gravel are compared to those of sand for engineering purpose. Two cylindrical containers for the model test were filled with marine clayey soil from the west coast of Korea with a column in the center, one with sand, the other with gravel. Vibrating wire type piezometers were installed at the distance of 1.0D, 1.5D and 2.0D from the center of the column. The characteristics of consolidation were studied with data obtained from the measuring instrument place on the surface of the container. The parameter study was performed on the marine clayey soil before and after the test in order to verify the effectiveness of the improvement. The clogging effect was checked at various depth in gravel column after the test. In-situ tests area was divided into two areas by material used. One is Sand Drain(SD) and Sand Compaction Pile(SCP) area, the other is Gravel Drain(GD) and Gravel Compaction Pile(GCP) area. Both areas were monitored to obtain the information on settlement, pore water pressure and bearing capacity by measuring instruments for stage loading caused by embankment. The results of measurements were analyzed. According to the test results, the settlement was found to be smaller in gravel drain than in sand drain. The increase in bearing capacity by gravel pile explains the result. The clogging effect was not found in gravel column. It is assumed that gravel is relatively acceptable as a drainage material. Gravel is considered to be a better material than sand for bearing capacity, and it is found that bearing capacity is larger when gravel is used as a gravel compaction pile than as a gravel drain.

  • PDF