• Title/Summary/Keyword: Dose-rate

Search Result 3,183, Processing Time 0.029 seconds

Efficacy of Single-Dose Antimicrobial Prophylaxis for Preventing Surgical Site Infection in Radical Gastrectomy for Gastric Carcin

  • Han, Ji Hoon;Jeong, Oh;Ryu, Seong Yeop;Jung, Mi Ran;Park, Young Kyu
    • Journal of Gastric Cancer
    • /
    • v.14 no.3
    • /
    • pp.156-163
    • /
    • 2014
  • Purpose: Information regarding antimicrobial prophylaxis (AMP) for gastric cancer surgery is limited. The present study investigated the efficacy of single-dose AMP for the prevention of surgical site infection (SSI) in patients undergoing gastrectomy for gastric carcinoma. Materials and Methods: Between 2011 and 2013, 1,330 gastric carcinoma surgery patients were divided into two AMP administration groups depending on the duration of treatment. Postoperative outcomes including morbidity and SSI were compared between the two groups overall and in matched patients. Risk factors for SSI were analyzed. Results: The extended group (n=1,129) received AMP until postoperative day 1 and the single-dose group (n=201) received single-dose AMP only during an operation. Postoperatively, there were no significant differences between the two groups with respect to overall morbidity, mortality, or length of hospital stay. The SSI rate of the single-dose group was not significantly different from that of the extended group overall (4.5% vs. 5.5%, respectively, P=0.556) or in matched patients (4.5% vs. 4.0%, respectively, P=0.801). There was no increase in the SSI rate of the single-dose group compared to the extended group in subgroups based on different clinicopathological and operative factors. Univariate and multivariate analyses revealed male gender, open surgery, and operating time (${\geq}180$ minutes) as independent risk factors for SSI. Conclusions: Single-dose AMP showed no increase in the postoperative SSI rate compared to postoperative extended use in patients undergoing gastrectomy for gastric carcinoma. The efficacy of single-dose AMP requires further investigation in randomized clinical trials specific to gastric cancer surgery.

Drug Utilization in Korean Children with Kawasaki Disease (국내 가와사키병 환아의 약물사용)

  • Cha, SungHee;Je, Nam Kyung
    • Korean Journal of Clinical Pharmacy
    • /
    • v.27 no.3
    • /
    • pp.127-135
    • /
    • 2017
  • Background: Kawasaki disease (KD) is an acute febrile, systemic vasculitis as a leading cause of acquired heart disease in children. Intravenous immunoglobulin G (IVIG) and aspirin are the standard initial therapy in the treatment of acute KD. The purpose of this study was to investigate drug utilization in children with KD, and to compare "IVIG + high-dose aspirin" and "IVIG + moderate-dose aspirin" in preventing cardiac complications. Methods: We analyzed pediatric patient sample data compiled by the Health Insurance Review & Assessment Service from 2010 to 2015. We identified patients with KD using the KCD-6 code of M30.3. We excluded patients in chronic phase or ${\geq}1$0 years. We also excluded patients who were diagnosed KD in November or December. Drug utilization pattern were assessed in acute KD patients and 30-day and 60-day cardiac complications were investigated between "IVIG + high-dose aspirin" group and "IVIG + moderate-dose aspirin" group. Results: In acute phase, IVIG was administered to 95.8% patients, and 57.1% patients were prescribed moderate-dose aspirin and 25% patients were with high-dose aspirin. Steroid use was rapidly increased from 4.0% in 2010 to 11.3% in 2015. Both 30-day and 60-day cardiac complications occurred less in "IVIG + high-dose aspirin" group compared to "IVIG + moderate-dose aspirin" group, but not statistically significant (0.9% vs 1.8%, p=0.252 for 30-day complication rate; 1.5% vs 2.7%. p=0.073 for 60-day complication rate). Conclusion: We were not able to demonstrate which aspirin therapy is superior for preventing cardiac complications in acute KD patients and further research is warranted.

Design of a New Applicator for High-Dose Rate Vaginal Brachytherapy (고선량율 질강 근접조사를 위한 새로운 적용구의 제작)

  • Shin, Sei One
    • Journal of Yeungnam Medical Science
    • /
    • v.17 no.2
    • /
    • pp.123-128
    • /
    • 2000
  • Purpose: This study was aimed to develop a new vaginal applicator(Shin's Applicator) for 2-channel high-dose rate vaginal brachytherapy to evaluate uniformity of surface dose, and to present 3-dimensional dose distribution of the applicator. Methods: Shin's Applicator was inexpensively constructed using human soft tissue equivalent acrylic bar. We evaluated dose uniformity along the applicator surface using film densitometer and performed vaginal intracavitary brachytherapy after insertion of the applicator using HDR brachytherapy planning software and brachytherapy unit(Ralstron-20B). Results: Shin's Applicator allows improved dose distribution than the existing 1-channel cylinder and achieves diminished urinary bladder and rectal dose by 20%. Conclusions: From the above results, it can be concluded that Shin's Applicator may be an improved form of a vaginal applicator. Furthermore, it can be suggested that this applicator has an advantage, for it prevents vaginal stenosis after radiation therapy and can be used as a disposable vaginal dilator. Further follow up examination with radiological study may be helpful to evaluate the therapeutic efficacy of this applicator.

  • PDF

Use of big data analysis to investigate the relationship between natural radiation dose rates and cancer incidences in Republic of Korea

  • Joo, Han Young;Kim, Jae Wook;Moon, Joo Hyun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1798-1806
    • /
    • 2020
  • In this study, we investigated whether there is a significant relationship between the natural radiation dose rate and the cancer incidences in Korea by using a big data analysis. The natural dose rate data for this analysis were the measurement data obtained from the 171 monitoring posts of the 113 administrative districts in Korea over the 10 years from 2007 to 2016. The relative cancer incidences for this analysis were the difference in the cancer patients per hundred thousand people year-on-year in the administrative districts with the five highest and the five lowest natural gamma dose rates each year over the same period. To analyze the correlation between the two variables, Spearman's rank correlation coefficient between the two rates was derived using R, a well-known big data analysis tool. The analysis showed that Spearman's rank correlation coefficient was more than 0.05 and that the correlation between the two variables was not statistically significant.

A Study on Dose Calculation in Intracavitary Radiotherapy of the Carcinoma of the Uterine Cervix with TAO Applicator (TAO Applicator를 이용한 자궁경암 강내조사시의 선양계산에 관한 고찰)

  • Kim, Chul-Soo;Kim, Jung-Jin
    • Radiation Oncology Journal
    • /
    • v.2 no.1
    • /
    • pp.101-106
    • /
    • 1984
  • Various methods are available for determination of exposure time in intracavitary radiotherapy of the carcinoma of the uterine cervix. To determine the accuracy of dose calculation with isodose curve for TAO applicator, comparison with results calculated by computer for radiotherapy treatment Planning was done in 24 procedures done in 12 consecutive patients with the carcinoma of the uterine cervix from May to December, 1983. The results are as follows: 1. The average dose rate Per hour of Point A was 87.70 rad, being 89.91 rad ana 85.49 rad in left and right, respectively. 2. The average percentage of dose rate of point A calculated by isodose curve method over that by computer was $101.28\%$ and the difference was less than $5\%$ in 17 Procedures and over $10\%$ in only 3 procedures. 3. The average percentage in case of point B was $108.67\%$. In conclusion, in most cases the difference was less than 200 rad for point A and less than 100 rad for point B during 2 courses of intracavitary radiotherapy. And so the dose rate calculation with isodose curve for TAO applicator is comparatively accurate.

  • PDF

Study on the Dose Calculation for Iridium and Cessium Sources (이리듐과 세슘의 혼합선원을 이용한 강내치료의 선량계획에 관한 연구)

  • Kang, Jeong-Ku;Kim, Soo-Kon
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.42-46
    • /
    • 2005
  • The Dose calculation program for the Buchler remote after-loading system was developed. We use iridium source for the tandem and cessium for the ovoids. We determined the source length and distributions by dividing the program disk to 72 points. The dose rate for the each program disk were calculated and stored to the tables for the xy coordinates. The dose rate for the interesting points for the patients were calculated by using these tables. We also made isodose curve from the calculations. By using the program, we could calculate the dose rate for the various points of the patient quickly and accurately.

  • PDF

A LONG-TERM FIELD TEST OF A LARGE VOLUME IONIZATION CHAMBER BASED AREA RADIATION MONITORING SYSTEM DEVELOPED AT KAERI

  • Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Kim, Jung-Bok;Kim, Young-Kyun;Jin, Hyung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.2
    • /
    • pp.77-81
    • /
    • 2009
  • An Area Radiation Monitoring System (ARMS) ionization chamber, which had an 11.8 L active volume, was fabricated and performance-tested at KAERI. Low leakage currents, linearities at low and high dose rates were achieved from performance tests. The correlation coefficients between the ionization currents and the dose rates are 1 at high dose rate and 0.99 at low dose rate. In this study, an integration-type ARMS ionization chamber was tested over a year for an evaluation of its long-term stability at a radioisotope (RI) repository of the Young-gwang nuclear power plant. The standard deviation of dose rate of 1 day data and over a 100-days mean value were 6.2 $\mu$R/h and 2.9 $\mu$R/h, respectively. The fabricated ARMS ionization chamber showed stable performance from the results of the long-term tests. Design and performance characteristics of the fabricated ionization chamber for the ARMS from performance-tests are also addressed.

Measurements of low dose rates of gamma-rays using position-sensitive plastic scintillation optical fiber detector

  • Song, Siwon;Kim, Jinhong;Park, Jae Hyung;Kim, Seunghyeon;Lim, Taeseob;Kim, Jin Ho;Kim, Sin;Lee, Bongsoo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3398-3402
    • /
    • 2022
  • We fabricated a 15 m long position-sensitive plastic scintillation optical fiber (PSOF) detector consisting of a PSOF, two photomultiplier tubes, four fast amplifiers, and a digitizer. A single PSOF was used as a sensing part to estimate the gamma-ray source position, and 137Cs, an uncollimated solid-disk-type radioactive isotope, was used as a gamma-ray emitter. To improve the sensitivity, accuracy, and measurement time of a PSOF detector compared to those of previous studies, the performance of the amplifier was optimized, and the digital signal processing (DSP) was newly designed in this study. Moreover, we could measure very low dose rates of gamma-rays with high sensitivity and accuracy in a very short time using our proposed PSOF detector. The results of this study indicate that it is possible to accurately and quickly locate the position of a very low dose rate gamma-ray source in a wide range of contaminated areas using the proposed position-sensitive PSOF detector.

The Study of Radiation Exposed dose According to 131I Radiation Isotope Therapy (131I 방사성 동위원소 치료에 따른 피폭 선량 연구)

  • Chang, Boseok;Yu, Seung-Man
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.653-659
    • /
    • 2019
  • The purpose of this study is to measure the (air dose rate of radiation dose) the discharged patient who was administrated high dose $^{131}I$ treatment, and to predict exposure radiation dose in public person. The dosimetric evaluation was performed according to the distance and angle using three copper rings in 30 patients who were treated with over 200mCi high dose Iodine therapy. The two observer were measured using a GM surverymeter with 8 point azimuth angle and three difference distance 50, 100, 150cm for precise radion dose measurement. We set up three predictive simulations to calculate the exposure dose based on this data. The most highest radiation dose rate was showed measuring angle $0^{\circ}$ at the height of 1m. The each distance average dose rate was used the azimuth angle average value of radiation dose rate. The maximum values of the external radiation dose rate depending on the distance were $214{\pm}16.5$, $59{\pm}9.1$ and $38{\pm}5.8{\mu}Sv/h$ at 50, 100, 150cm, respectively. If high dose Iodine treatment patient moves 5 hours using public transportation, an unspecified person in a side seat at 50cm is exposed 1.14 mSv radiation dose. A person who cares for 4days at a distance of 1 meter from a patient wearing a urine bag receives a maximum radiation dose of 6.5mSv. The maximum dose of radiation that a guardian can receive is 1.08mSv at a distance of 1.5m for 7days. The annual radiation dose limit is exceeded in a short time when applied the our developed radiation dose predictive modeling on the general public person who was around the patients with Iodine therapy. This study can be helpful in suggesting a reasonable guideline of the general public person protection system after discharge of high dose Iodine administered patients.

Residual Patterns of Strobilurin Fungicides in Korean Melon under Plastic Film House Condition (Strobilurin계 살균제의 시설재배 참외 중 잔류 양상)

  • Park, Eun-Jeong;Lee, Ju-Hee;Kim, Tae-Hwa;Kim, Jang-Eok
    • Korean Journal of Environmental Agriculture
    • /
    • v.28 no.3
    • /
    • pp.281-288
    • /
    • 2009
  • The strobilurin fungicides, azoxystrobin and kresoxim-methyl, were investigated to know the biological half-lives and dissipation patterns in Korean melon under plastic film house condition. Used pesticides for field application were 20% azoxystrobin of suspension concentrate and 47% kresoxim-methyl of water dispersible granule. Two pesticides were sprayed at recommended and double dose rate. Pesticide residues in Korean melon were analyzed until 14 days after application. The azoxystrobin was analyzed by HPLC equipped with UV detector after cleanup with florisil glass column. Initial residue concentrations of azoxystrobin in Korean melon at recommended and double dose rate were 0.09 mg/kg and 0.14 mg/kg, respectively. Those were less than 0.2 mg/kg maximum residue limit of Korean melon established by KFDA. The biological half-lives of azoxystrobin in Korean melon were 4.7 days at recommended dose rate and 7.8 days at double dose rate. Initial concentrations of kresoxim-methyl which was analyzed by GLC-ECD in Korean melon at recommended and double dose rate were 0.10 mg/kg and 0.23 mg/kg, respectively. Those were less than 1.0 mg/kg, MRL. The biological half-lives of kresoxim-methyl in Korean melon were 4.1 days at recommended dose rate and 4.8 days at double dose rate. The residue amounts of both pesticide was lower than MRL and biological half-lives were not so long. Because the weight of Korean melon under plastic film house condition was fast increased during cultivation.