Browse > Article

A LONG-TERM FIELD TEST OF A LARGE VOLUME IONIZATION CHAMBER BASED AREA RADIATION MONITORING SYSTEM DEVELOPED AT KAERI  

Kim, Han-Soo (Korea Atomic Energy Research Institute)
Ha, Jang-Ho (Korea Atomic Energy Research Institute)
Park, Se-Hwan (Korea Atomic Energy Research Institute)
Kim, Jung-Bok (Korea Atomic Energy Research Institute)
Kim, Young-Kyun (Department of Nuclear Engineering, Hanyang University)
Jin, Hyung-Ho (Korea Hydro & Nuclear Power Co., Ltd, Young-gwang Nuclear Power site)
Publication Information
Journal of Radiation Protection and Research / v.34, no.2, 2009 , pp. 77-81 More about this Journal
Abstract
An Area Radiation Monitoring System (ARMS) ionization chamber, which had an 11.8 L active volume, was fabricated and performance-tested at KAERI. Low leakage currents, linearities at low and high dose rates were achieved from performance tests. The correlation coefficients between the ionization currents and the dose rates are 1 at high dose rate and 0.99 at low dose rate. In this study, an integration-type ARMS ionization chamber was tested over a year for an evaluation of its long-term stability at a radioisotope (RI) repository of the Young-gwang nuclear power plant. The standard deviation of dose rate of 1 day data and over a 100-days mean value were 6.2 $\mu$R/h and 2.9 $\mu$R/h, respectively. The fabricated ARMS ionization chamber showed stable performance from the results of the long-term tests. Design and performance characteristics of the fabricated ionization chamber for the ARMS from performance-tests are also addressed.
Keywords
ARMS (Area Radiation Monitoring System); Ionization Chamber; Long-term Stability; Linearity; Nuclear Power Plant;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Bohm J. Saturation corrections for plane-parallel ionization chambers. Phys. Med. Biol. 1976;21:754-761   DOI   PUBMED   ScienceOn
2 Scott PB, Greening JR. The determination of saturation currents in free-air ionization chambers by extrapolation method. Phys. Med. Biol. 1963;8:51-59   DOI   ScienceOn
3 IAEA, Technical Report Series No. 277. 1987
4 Decampo JA, Beck HL, Raft PD. High pressure argon ionization chamber systems for the measurement of environmental radiation exposure rates. New York, U. S. Atomic Energy Commission, 1972:1-69
5 Kenneth RK. The dosimetry of ionizing radiation. Vol.2, New York; Academic press, 1987: 169-243
6 Piermattei A, Azario L, Arcovito G, Toni M. Ionrecombination correction factor ${k}^{sat}$ for spherical ion chambers irradiated by continuous photon beams. Phys. Med. Biol. 1996;41:1025-1035   DOI   ScienceOn
7 Knoll GF. Radiation detection and measurement. 3th ed. New York; John Wiley and Sons, 1999:129-157
8 Keithley Model 6517A. Electrometer user's manual, http://www.keithley.com
9 Burlin TE. A general theory of cavity ionization. Br. J. Radiol. 1966;39:727-734   DOI   ScienceOn
10 Weinhous MS, Meli A. Determining P$_{ion}$, the correction factor for recombination losses in an ionization chamber. Med. Phys. 1984;11:849-856   DOI   PUBMED   ScienceOn