• 제목/요약/키워드: Dental implant-abutment interface

검색결과 56건 처리시간 0.029초

Bone loss-related factors in tissue and bone level dental implants: a systematic review of clinical trials

  • Mortazavi, Hamed;Khodadoustan, Amin;Kheiri, Aida;Kheiri, Lida
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권3호
    • /
    • pp.153-174
    • /
    • 2021
  • Dental implants are popular for dental rehabilitation after tooth loss. The goal of this systematic review was to assess bone changes around bone-level and tissue-level implants and the possible causes. Electronic searches of PubMed, Google Scholar, Scopus, and Web of Science, and a hand search limited to English language clinical trials were performed according to PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analysis) guidelines up to September 2020. Studies that stated the type of implants used, and that reported bone-level changes after insertion met the inclusion criteria. The risk of bias was also evaluated. A total of 38 studies were included. Eighteen studies only used bone-level implants, 10 utilized tissue-level designs and 10 observed bone-level changes in both types of implants. Based on bias assessments, evaluating the risk of bias was not applicable in most studies. There are vast differences in methodologies, follow-ups, and multifactorial characteristics of bone loss around implants, which makes direct comparison impossible. Therefore, further well-structured studies are needed.

임플란트 매식 시 수직골 높이에 따른 응력분석 (Stress analysis according to the vertical bone level in the implant placement)

  • 김민호;박영록;계기성
    • 구강회복응용과학지
    • /
    • 제18권4호
    • /
    • pp.301-311
    • /
    • 2002
  • The purpose of this study was to compare the distributing pattern of stress on the finite element models with the different vertical bone level of implant fixture. The two kinds of finite element models were designed according to vertical bone level around fixture ($4.0mm{\times}11.5mm$). The cemented crowns for mandibular first and second molars were made. Three- dimensional finite element model was created with the components of the implant and surrounding bone. Vertical loads were applied with force of 200N distributed within 0.5mm radius circle from the center of central fossa and distance 2mm and 4 mm apart from the center of central fossa. Von-Mises stresses were recorded and compared in the supporting bone, fixtures, abutment screws, and crown. The results were as following : (1) In vertical loading at the center circle of central fossa on model 1 and 2, the difference from vertical bone in implant placement did not affect the stress pattern on all components of implant except for crown. (2) With offset distance incerasing and the bone level of implant decreasing, the concentration of stress occured in the buccal side of long crown, around the buccal crestal bone, and on the fixture- abutment interface. As a conclusion, the research showed a tendency to increase the stress on the supporting bone, fixture and screw under the offset loads when the vertical level of bone around fixture was different. Since the same vertical bone bed has more benefits than the different bone bed around fixtures, it is important to prepare a same vertical level of bone bed for the success of implants under occlusal loads.

임플란트 지대주 종류와 동적하중이 고정체와 지대주의 미세간극에 미치는 영향 (The Effect of Types of Abutment and Dynamic Loading on Microgap between Implant Fixture and Abutment)

  • 오병두;최유성;신수연
    • 구강회복응용과학지
    • /
    • 제26권4호
    • /
    • pp.389-403
    • /
    • 2010
  • 이전부터 사용된 티타늄, 금합금 지대주 및 최근 사용이 급증한 지르코니아 지대주와 임플란트의 계면에 대한 비교 연구와 동적하중이 계면에 미치는 영향에 관한 연구가 많지 않은 실정이다. 본 연구에서 지대주 종류와 동적 하중에 따른 미세간극의 차이를 주사전자현미경 분석을 통하여 비교평가 하였다. USII ${\phi}3.75{\times}11.5mm$ (Osstem Co., Seoul, Korea) 티타늄 임플란트에 티타늄 지대주, 지르코니아 지대주, 주조 금합금 (UCLA plastic) 지대주를 각 군당 7개씩, 30Ncm의 조임회전력으로 연결하였다. 25-250N의 sine형 동적하중을 장축 방향에서 $30^{\circ}$ 경사로 $10^5$회 시행하였다. 하중 전후에 계면의 미세간극을 순측, 구개측, 근심측, 원심측 부위에서 측정하였고, 그 결과 동적 하중으로 인한 통계적 유의성은 없었다. 지대주 종류에 따른 미세간극을 비교한 결과, 동적하중 시행 전후 모두 UCLA 군과 티타늄 군, UCLA 군과 지르코니아 군 사이에 통계적으로 유의한 차이를 보였다(p<0.05). 티타늄 군과 지르코니아 군 사이에는 유의한 차이를 보이지 않았다. UCLA 지대주는 정밀 연삭된 티타늄, 지르코니아 지대주 보다 더 큰 미세간극을 보였고 $10^5$회 동적하중은 미세간극에 영향을 미치지 않았다.

내부연결 원추형 임플란트의 육각구조의 유무에 따른 연결부 안정성: 실험적 연구 (Joint stability of internal conical connection abutments with or without hexagon indexes: an in vitro study)

  • 이상운;차민상;이지혜;조리라;박찬진
    • 구강회복응용과학지
    • /
    • 제36권2호
    • /
    • pp.95-103
    • /
    • 2020
  • 목적: 본 연구의 목적은 내부연결 원추형 임플란트의 육각구조 유무가 임플란트 지대주 장축변위와 임플란트 지대주 나사의 풀림토크에 미치는 영향을 평가하고자 하였다. 연구 재료 및 방법: 내부연결 원추형 임플란트를 육각구조를 가진 지대주 그룹(HEX)과 육각구조를 갖지 않는 지대주 그룹(CON)으로 나누고 각 그룹 당 10쌍의 시편을 체결하였다. 지대주 나사를 30 Ncm 조임회전력을 가하여 체결한 뒤 장축변위 및 풀림토크값을 측정하고 250 N 수직적 반복하중을 100,000회 가한 뒤 장축변위 및 풀림토크값을 측정하였다. 각 단계마다 디지털 마이크로미터를 이용하여 임플란트 직경과 수직적 높이를 측정하였고 전자 토크게이지를 이용하여 풀림토크값을 측정하였다. 각 군간의 값의 유의차를 확인하기 위하여 독립 표본 T 검정을 이용하여 통계분석하였다(α = 0.05). 결과: HEX 군은 조임회전력을 가한 뒤 유의하게 높은 장축변위를 나타내였다(P < 0.05). HEX 군과 CON 군은 수직적 반복하중 후 장축변위에 유의한 차이를 보이지 않았다(P = 0.052). HEX 군과 CON 군은 수직적 반복하중 전, 후 풀림토크값 모두 유의한 차이를 보이지 않았다(P = 0.057 and P = 0.138). 모든 그룹에서 반복하중 후 풀림토크값 상실율이 증가하였다(P < 0.05). 결론: 내부연결 원추형 임플란트에서 육각구조를 가진 경우 장축 변위가 더 컸으며, 그 외의 연결부 안정성은 유사하였다. 모든 그룹에서 반복하중 후 풀림토크값 상실율이 증가하였다.

연결부 형태가 다른 두 가지 scallop 임플란트에서 경부 나사선 피치가 응력 분포에 미치는 영향 : 삼차원적유한요소분석 (Effects of Coronal Thread Pitch in Scalloped Implant with 2 Different Connections on Loading Stress using 3 Dimensional Finite Element Analysis)

  • 최경수;박성훈;이재훈;허중보;윤미정;전영찬;정창모
    • 구강회복응용과학지
    • /
    • 제29권2호
    • /
    • pp.111-118
    • /
    • 2013
  • 본 연구는 삼차원적 유한요소분석을 통하여 연결부 형태가 다른 두 가지 scallop 임플란트의 경부 나사선 피치가 응력 분포에 미치는 영향을 간접적으로 확인하고자 하였다. 4가지 경부 나사선 피치 (0.4mm, 0.5mm, 0.6mm, 0.7mm)를 갖는 scallop 임플란트를 두 가지 다른 연결부 형태 (platform matching connection, platform mismatching connection)로 지대주와 연결되는 유한요소모형을 설계하였다. 8개의 모든 모델에 100N의 하중을 수직 및 30도 경사 방향으로 인가하여, 임플란트, 지대주, 그리고 치조골에 가해지는 최대등가응력을 분석하였다. 유한요소분석결과 응력은 치밀골에 집중되었다. 작은 나사 피치가 설계된 platform mismatching connection 모델에서 수직 방향과 경사하중 시 최대등가응력이 가장 낮게 나타났다. 측정되었다. Platform matching connection 모델에서는 경사하중의 경우 0.6mm, 수직하중의 경우 0.4mm 나사 피치에서 가장 낮은 최대등가응력을 보였다. 따라서 scallop 임플란트에서 platform mismatching connection은 최대등가응력을 감소시키는 데 중요한 역할을 하며, 경부 나사 피치가 작을수록 최대등가응력이 감소되는 경향을 보임을 알 수 있었다.

임플란트 나사의 안정성 (Stability of implant screw joint)

  • 정재헌;곽종하;장두익
    • 구강회복응용과학지
    • /
    • 제19권2호
    • /
    • pp.125-137
    • /
    • 2003
  • The use of screw-retaind prosthesis on an osseointegrated implant is a popular treatment modality offering relative ease in the removal of the restoration. One of the complications associated with this modality is the loosening of the abutment and coping screws. Loosening of the screws results in patient dissatisfaction, frustration to the dentist and, if left untreated, component fracture. There are several factors which contribute to the loosening of implant components which can be controlled by the restorative dentist and lab technician. This article offers pratical solutions to minimize this clinical problem and describes the factors involved in maintaining a stable screw joint assembly. To avoid joint failure, adherence to specific clinical, as well as mechanical, parameters is critical. With respect to hardware, optimal tolerance and fit, minimal rotational play, best physical properties, a predictable interface, and optimal torque application are mandatory. In the clinical arena, optimal implant distribution; load in line with implant axis; optimal number, diameter, and length of implants; elimination of cantilevers; optimal prosthesis fit; and occlusal load control are equally important.

임플란트 국소의치 금나사의 3차원 유한요소법 접촉응력 분석 (3D Dimensional Finite Element Analysis of Contact Stress of Gold Screws in Implant Partial Denture)

  • 이명곤
    • 대한치과기공학회지
    • /
    • 제35권4호
    • /
    • pp.303-312
    • /
    • 2013
  • Purpose: In this research, non-linear three dimensional finite element models with contact elements were constructed. For the investigations of the distributions of contact stresses, 3 units fixed partial dentures model were studied, especially on the interface of the gold screw and cylinder, abutment screw. Methods: 3 types of models were constructed ; the basic fixed partial denture in molar region with 3 units and 3 implants, the intermediate pontic fixed partial denture model with 3 units and 2 implants, and the extension pontic fixed partial denture model with 3 units and 2 implants. For all types, the external loading due to chewing was simulated by applying $45^{\circ}$ linguo-buccal loading of 300 N to the medial crown. For the simulation of the clamping force which clinically occurs due to the torque, thermal expansion was provided to the cylinder as a preload. Results: Under 300 N concentrated loading to the medial crown, the maximum contact stress between abutment screw and gold screw was 86.85~175.86MPa without preload, while the maximum contact stress on the same area was 25.59~57.84MPa with preload. Conclusion: The preloading affected the outcomes of the finite element stress analysis. Reflecting the clinical conditions, the preloading conditions should be considered for other practical study utilizing FEA. For the study of the contact stresses and related motions, various conditions, such as frictional coefficient changes, gap between contact surfaces, were also varied and analyzed.

내측 연결 및 외측 연결 방식으로 설계된 임플란트의 3차원적 유한요소 응력 분석 (Stress distribution of implants with external and internal connection design: a 3-D finite element analysis)

  • 정현주;양성표;박재호;박찬;신진호;양홍서
    • 구강회복응용과학지
    • /
    • 제33권3호
    • /
    • pp.189-198
    • /
    • 2017
  • 목적: 외측 육각형과 내측 원추형 연결부로 설계된 임플란트 지지 하악 구치 수복물에 교합력을 가할때 발생하는 생역학 현상을 분석하고자 한다. 연구 재료 및 방법: 외측 연결형 임플란트(EXHEX)와 내측 연결형 임플란트(INCON) 그리고 이와 결합할 해당 나사와 지대주 및 크라운을 제작하였고, 하악 무치악 치조골을 설계하였다. 각 부분을 조립하여 2종의 유한요소 모형을 제작하였다. 총 120 N 크기의 수직력(L1)과 45도 측방력(L2)을 가하였고, 유한요소 응력 분석을 시행하였다. 결과: L2 측방력 하중에 의해 발생한 최대 응력은 L1 수직력 하중에 의한 것 보다 6 - 15배 더 컸다. INCON 모델은 EXHEX 모델보다 크라운 교두부에서 2.2배 더 큰 변위량을 보여 주었다. 측방력에 의해 EXHEX 모델은 나사에서, INCON 모델은 임플란트 고정체의 상단 변연부에서 폰미세스 응력의 최대값이 관찰 되었다. INCON 모델에서는 임플란트 내부 계면에서 긴밀한 접촉이 유지 되었다. 결론: 측방력이 큰 변형과 응력을 발생하였으나, 임플란트에서의 최대 응력 발생부위는 INCON과 EXHEX 모델이 서로 상이하였다.

임플란트 지지 나사-시멘트 유지형 보철물에서 보철물-지대주 제거 후 변연부 연마의 효과: 증례보고 (Burnishing effect on marginal misfit of implant-supported screw-and-cement retained prostheses: A case report)

  • 김미주;이두형
    • 대한치과보철학회지
    • /
    • 제58권3호
    • /
    • pp.239-243
    • /
    • 2020
  • 고정성 보철물의 변연 적합도가 낮은 경우 치태침착, 치주질환, 치아과민, 보철물 구성요소 파절, 시멘트 상실 등의 생물학적, 기계적 합병증이 발생할 가능성이 증가할 수 있다. 이러한 합병증은 보철물의 장기간의 성공과 생존에 영향을 미친다. 본 증례는 임플란트 지지 나사-시멘트 유지형 보철물에서 보철물 장착 시 보철물-지대주를 제거하고 변연부를 연마하여 변연간극을 최소화할 수 있는 임상과정을 보여준다. 그리고 변연 간극을 연마 전과 후에 측정하여 비교 관찰하였다. 본 기술은 변연 적합도를 높여 보철물의 수명 연장에 기여할 수 있다.

변형된 임플란트 임시 지대주의 물성에 대한 연구 (The Study on the Physical Property of Provisional Prosthesis using Modified Temporary Abutment)

  • 양병덕;윤태호;최운재;박주미
    • 구강회복응용과학지
    • /
    • 제22권4호
    • /
    • pp.329-340
    • /
    • 2006
  • Statement of problem: Damping of the peak force transmitted to implants has been reported by in vitro studies using impact forces on resin-veneered superstructures. Theoretical assumptions suggest that use of acrylic resin for the occlusal surfaces of a prosthesis would protect the connection between implant and bone. Therefore, the relationship between prosthesis materials and the force transmitted through the implant system also needs to be investigated under conditions that resemble the intraoral mechanical environment. Purpose: The purpose of this study was to analyze the fracture strength and modes of temporary prosthesis when a flange or occlusally extended structure were connected on the top of the abutment. Material and method: Modified abutments of winged and bulk design were made by casting the desired wax pattern which is made on the UCLA type plastic cylinder. Temporary crowns were made using templates on the modified abutments, and its fracture toughness and strain were compared to the traditional temporary prosthesis. To evaluate the effect of aging, 5.000 times of thermocycling were performed, and their result was compared to the 24hours specimen result. Results: The following conclusions were drawn from this study: 1. In the fracture toughness test, temporary crown's fracture line located next to the screw hole while modified designs with metal support showed fracture line on the metal and its propagation along the metal-resin interface. 2. Wing and bulk structure didn't show significant difference in the fracture toughness (p>0.05), but wing structure showed stress concentration on the screw hole area compared to bulk structure which showed even stress distribution. 3. In the fracture toughness test after thermocycling, wing and bulk structure showed increased or similar results in metal supported area while off-metal area and temporary crown showed decreased results. 4. In the strain measurement after thermocycling, its value increased in the temporary and bulk structure. However, wing structure showed decreased value in the loading point while increased value in the screw hole area. Conclusion: Wing type design showed compatible result to the bulk type that its application with composite resin prosthesis to the implant dentistry is considered promising.