Browse > Article
http://dx.doi.org/10.14347/kadt.2013.35.4.303

3D Dimensional Finite Element Analysis of Contact Stress of Gold Screws in Implant Partial Denture  

Lee, Myung-Kon (Dept. of Dental Laboratory Science, College of Health Sciences, Catholic University of Pusan)
Publication Information
Journal of Technologic Dentistry / v.35, no.4, 2013 , pp. 303-312 More about this Journal
Abstract
Purpose: In this research, non-linear three dimensional finite element models with contact elements were constructed. For the investigations of the distributions of contact stresses, 3 units fixed partial dentures model were studied, especially on the interface of the gold screw and cylinder, abutment screw. Methods: 3 types of models were constructed ; the basic fixed partial denture in molar region with 3 units and 3 implants, the intermediate pontic fixed partial denture model with 3 units and 2 implants, and the extension pontic fixed partial denture model with 3 units and 2 implants. For all types, the external loading due to chewing was simulated by applying $45^{\circ}$ linguo-buccal loading of 300 N to the medial crown. For the simulation of the clamping force which clinically occurs due to the torque, thermal expansion was provided to the cylinder as a preload. Results: Under 300 N concentrated loading to the medial crown, the maximum contact stress between abutment screw and gold screw was 86.85~175.86MPa without preload, while the maximum contact stress on the same area was 25.59~57.84MPa with preload. Conclusion: The preloading affected the outcomes of the finite element stress analysis. Reflecting the clinical conditions, the preloading conditions should be considered for other practical study utilizing FEA. For the study of the contact stresses and related motions, various conditions, such as frictional coefficient changes, gap between contact surfaces, were also varied and analyzed.
Keywords
Contact Stress; Finite Element Analysis; Gold Screw; Implant;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Akca K, Cehreli MC, Iplikcioglu H. Evaluation of the mechanical characteristics of the implant-abutment complex of a reduceddiameter morse-taper implant. Clin Oral Implants Res, 14(4), 444-454, 2003.   DOI   ScienceOn
2 Akour SN, Fayyad MA, Nayfeh JF. Finite element analyses of two antirotational designs of implant fixtures. Implant Dent. 14(1), 77-81, 2005.   DOI   ScienceOn
3 Alkan I, Sertgoz A, Ekici B. Influence of occlusal forces on stress distribution in preloaded dental implant screws. J Prosthet Dent, 91(4), 319-325, 2004.   DOI   ScienceOn
4 Chung CH, Shin JY, Lee JK, Son MK. Cementretained versus screw-retained implant restoration. Oral Biology Research, 21(1), 149-158, 1997.
5 Eraslan O, Sevimay M, Usumez A, et al. Effects of cantilever design in stress distribution in fixed partial dentures-a finite element analysis. J Oral Rehabil, 32(4), 273-278, 2005.   DOI   ScienceOn
6 Eskitascioglu G, Usumez A, Sevimay M, Soykan E, Unsal E. The influence of occlusal loading location on stresses transferred to implantsupported prostheses and supporting bone : A three-dimensional finite element study. J Prosthet Dent, 91(2), 144-150, 2004.   DOI   ScienceOn
7 Geng JP, Ma QS, Xu W, Tan KB, Liu GR. Finite element analysis of four thread-form configurations in a stepped screw implant. J Oral Rehabil, 31(3): 233-239, 2004.   DOI   ScienceOn
8 Hebel KS, Gajjar RC. Cement-retained versus screw-retained implant restorations: achieving optimal occlusion and esthetics in implant dentistry. J Prosthet Dent, 77(1), 28-35, 1997.   DOI   ScienceOn
9 Ishigaki S, Nakano T, Yamada S, Biomechanical stress in bone surrounding an implant under simulated chewing. Clin Oral Implants Res, 14(1), 97-102, 2003.   DOI   ScienceOn
10 Johansson LA, Ekfeldt A. Implant-supported fixed partial prostheses: A retrospective study. Int J Prosthodont, 16(2), 172-176, 2003.
11 Kim IK, Lee HU, Ryu SH, Choi JH, Han YS, Son CY, Byun HI. The three dimensional finite element analysis of the stress distribution in the three treatment options of implants restorations for the posterior partial edetulism. Journal of Korean Academy of Oral and Maxillofacial Surgery, 30(3), 175-180, 2004.
12 Kim YS, Lee DK, Min SK, Lee J, Moon C. Clinical study on success rate of osseointegrated dental implants. The Journal of Korean Association of Maxillofacial Plastic and Reconstructive Surgeons, 24(2), 137-147, 2002.   과학기술학회마을
13 Kwon HJ, Cho HW. Three-dimensional finite element stress analysis of single implant prosthesis using different fixture and abutment screw diameters. Journal of Wonkwang dental Research institute, 10(2), 1-14, 2001.
14 Lang LA, Kang B, Wang RF, Lang BR. Finite element analysis to determine implant preload. J Prosthet Dent, 90(6), 539-545, 2003.   DOI   ScienceOn
15 Lee MK, Kim YJ, Kim CY. A comparative analysis of stress distrbution in the implant supporting bone by occlusal loading location utilizing the finite element method. The Journal of the Korean Academy of Dental Technology, 27(1), 105-112, 2005.
16 Nam YK, Jang BS, Um HS. A two-year retrospective study on the clinical success of Korean implant systems. Journal of Periodontal & Implant Science, 33(1), 37-47, 2003.
17 Lee TY, Kang JS, Lee SH, Ahn OJ, Kang DW. Stress analysis according to the different angulation in the implant placement. Oral Biology Rsearch, 26(2), 17-30, 2002.
18 McGlumphy EA, Mendel DA, Holloway JA. Implants screw mechanics. Dent Clin North Am, 42(1), 71-89, 1998.
19 Min SK, Cha JW, Oh SH. Clinical study on success rate of single tooth implant. The Journal of Korean Association of Maxillofacial Plastic and Reconstructive Surgeons, 25(6), 542-551, 2003.
20 Pierrisnard L, Renouard F, Renault P, Barquins M. Influence of implant length and bicortical anchorage on implant stress distribution. Clin Implant Dent Relat Res, 5(4), 254-262, 2003.   DOI   ScienceOn
21 Sakaguchi R, Borgersen SE. Nonlinear contact analysis of preload in dental implant screws. Int J Oral Maxillofac Implants, 10(3), 295-302, 1995.
22 Sato Y, Shindoi N, Hosokawa R, Tsuga K, Akagawa Y. A biomechanical effect of wide implant placement and offset placement of three implants in the posterior partially edentulous region. J Oral Rehabil, 27(1), 15-21, 2000.   DOI   ScienceOn
23 Singer A, Serfaty V. Cement-retained implantsupported fixed partial denture: a 6-month to 3-year follow-up. Int J Oral Maxillofac Implants, 11(5), 645-649, 1996.
24 Son SS, Kim YJ, Lee MK. Finite element analysis of stress distribution on supporting bone of posterior implant partial dentures by loading location. The Journal of the Korean Academy of Dental Technology, 29(1), 93-101, 2007.   과학기술학회마을
25 Stegaroiu R, Sato T, Kusakari H, Miyakawa O. Influence of restoration type on stress distribution in bone around implant: a threedimensional finite element analysis. Int J Oral Maxillofac Implants, 13(1), 82-90, 1998.
26 Son SS, Lee MK. Finite element stress analysis on supporting bone by tripodal placement of implant fixture. The Journal of the Korean Academy of Dental Technology, 31(1), 7-15, 2009.   과학기술학회마을