• 제목/요약/키워드: Dental Laboratory Technology

검색결과 686건 처리시간 0.026초

직무만족(職務滿足)과 관련(關聯) 변인(變人)에 관한 연구(硏究) (A Study on the Job Satisfaction and It's related Variables)

  • 최석순
    • 대한치과기공학회지
    • /
    • 제13권1호
    • /
    • pp.99-122
    • /
    • 1991
  • This study was conducted to investigate the job satisfaction of the dental technicians and evalate the relationship between it’s scores and certain variables. One hundred eighty dental technicians were sampled from 300 among the 2552 dental technicians by wide distribution method, in September 1990. Data were collected by administering the instrument, the researcher developed for measuring the independent and dependent variables. The statistical methods utilized in this study were one-way analysis of variance, correlation and multiple regression analysis. The data were analyzed by SPSS(Statistical Package for Social Science), utilizing PC. The statistical significance was tested at 0.05 level. The major findings of the study were as follows : 1. The job satisfaction measuring instrument, the researcher developed, could measured the job satisfaction of dental technicians. The Maximum score of the instrument was 125, the highest score of dental technicians was 106, the lowest score was obtained 38, the mean score was 72.228 and standard deviation was 12.804. 2. The personal variables of dental technicians were related with the job satisfaction scores. The job satisfaction scores were positively correlated, at 0.01 level, with the scores of age(r=0.379), year(r=0.218), aptitude(r=0.415), marry(r=0.202), income(r=0.381), career(r=0.316). 3. The family variables scores of dental technicians were not correlated with the job satisfaction scores. 4. The personal characteristics of dental technicians were related with the job satisfaction. The job satisfaction score were positively correlated beyond the significant level, with the cheerfulness scores(r=0.398) and stability scores(r=0.224). 5. The job-related variables of the dental technicians were related with the job satisfaction scores. The correlation coefficient between job satisfaction scores and turnover scores was r=0.23, and quantity scores was r=0.300.

  • PDF

치위생학 전공 대학생의 임상실습 전환충격, 회복탄력성이 학업소진에 미치는 영향 (Effect of clinical practice transition shock and resilience on academic burnout of dental hygiene students)

  • 문상은;문혜수;김은채;김민지
    • 한국치위생학회지
    • /
    • 제22권6호
    • /
    • pp.541-550
    • /
    • 2022
  • Objectives: This study aimed to verify the degree of clinical practice transition shock, resilience, and academic burnout of dental hygiene students, and analyze factors affecting academic burnout. Methods: From September 1 to September 20, 2022, this study collected data from 201 dental hygiene students who experienced clinical practice, and subsequently conducted a t-test, one-way ANOVA, Pearson correlation analysis, and multiple regression analysis using the SPSS Statistics 22. Results: The transition shock and resilience showed a significantly negative correlation (r=-0.211), transition shock and academic burnout showed a significantly positive correlation (r=0.484), and resilience and academic burnout showed a significantly negative correlation (r=-0.568). Regarding factors affecting academic burnout, academic burnout increased when the transition shock was greater (β=0.263, p<0.001), major satisfaction after clinical practice was lower (β=0.180, p<0.05), and the average grades were lower (β=0.169, p<0.01). Academic burnout decreased when resilience was greater (β=-0.435, p<0.001). Conclusions: To prevent clinical practice transition shock and academic burnout, and to increase the resilience of dental hygiene students, it would be necessary to establish learning strategies, change the educational environment, and establish a systematic clinical practice management program.

AN STUDY ON THE DIMENSIONAL CHANGE OF PLASTER TO TIME WITH IMPRESSION MATERIALS

  • 최석순
    • 대한치과기공학회지
    • /
    • 제10권1호
    • /
    • pp.43-46
    • /
    • 1988
  • The purpose of this investigation was to determined the dimensional change of plaster to time with impression materials. This study was carried out through the literature & experiment, using 4sorts of the Impression Materials(Alginate, Impression Agar, Silicone Rubber, Polysulfide Rybber)and 5 treatments(1hr, 11/2 hrs, 2hur, 3hur, 6hur). The results of this experiment were as follows : 1. Main effect of Impression Meterials & tretments was statistically significant.(P<0.01). 2. The effect of 2-way interaction of Impression materials & Treatments was also statistically significant.(P<0.01) 3. Though this study was the difference of degree according to the materials. All Impression Materials were tended to be constained according to over the time.

  • PDF

진동기의 단계별 조절이 모형 제작시 기포발생에 미치는 영향에 관한 연구 (A Study to Effect on the Porosity when Model Making for Control of Vibrator)

  • 이도경
    • 대한치과기공학회지
    • /
    • 제13권1호
    • /
    • pp.15-19
    • /
    • 1991
  • This study was made to effect on the porosity when model making for control of vibrator. Samples of total 600 were made by plaster and stone divided low, medium and high which is 100 each. The following results were obtained to observation porosity of surface by eyes. 1. Second stage was fewer than third stage, first stage was fewer than third stage in porosity number of plaster model. 2. Second stage was fewer than first stage in porosity number of stone model. 3. Stone model was fewer than plaster model in porosity number of third stage.

  • PDF

영구치 전치의 근원심경과 치관 길이에 관한 연구 (A Study on the Mesio-Distal Crown Diameters and Crown Length of the Permanent Anterior Teeth)

  • 이태정
    • 대한치과기공학회지
    • /
    • 제13권1호
    • /
    • pp.21-26
    • /
    • 1991
  • The mesiodistal crown diameters and crown length of the permanent anterior teeth have been studied and analyzed about the mean size, S.D, S.E etcs from stone models of 100 Korean male and 74 female. From the study, the following conclusions were made : 1. Statistical differences of left and right teeth were not found in the mesio distal crown diameters and crown length of the permanent anterior teeth. 2. The mean values of mesiodistal crown diameters of permanent anterior teeth were slightly larger in male than in females and statistical differences of males and females were found in maxillary right central incisor, mandibular left canine, mandibular right lateral incisor and mandibular right canine. 3. The mean values of crown length of permanent anterior teeth were slightly larger in male than in female and statistical differences of males and females were found in mandibular left canine, mandibular right canine. 4. Mesiodistal crown diameters and crown length of maxillary left lateral incisors and right lateral incisors of female are larger than that of male.

  • PDF

도재용 금합금 재사용에 따른 변연 적합도에 관한 연구 (A study on the marginal fitness to reuse with a Au-Pt-Pd alloy for porcelain fused to metal crown)

  • 문희경
    • 대한치과기공학회지
    • /
    • 제32권1호
    • /
    • pp.17-21
    • /
    • 2010
  • This experimental study was to determine the fitness in each cervical margin of reusing porcelain gold alloy. The gold alloy used in this experimental study was a Au-Pt-Pd alloy (BDCG-898, Bukwang Inc, Korea) for the fabrication of porcelain fused to metal crown. Twenty-five copings were divided into the five groups. And the group A, B, C, D and E were cording successively according to the frequency of reuse to five times. Each specimen was reused without adding new metal. The experimental results were as follows: 1. The group A, B, C showed good fitness in each cervical margin. 2. The group D got good fitness in labio and linguo cervical margin, but the mesio and disto cervical margin showed more than $40{\mu}m$ 3. The group E showed worse fitness than the other groups in each cervical margin.

유리침투 지르코니아 복합체의 굴곡 강도 (Flexure Strength of Glass-infiltrated Zirconia Complex)

  • 김사학
    • 대한치과기공학회지
    • /
    • 제31권2호
    • /
    • pp.9-14
    • /
    • 2009
  • In this study, to improve the flexure strength of Zirconia, on the Zirconia pellet surface measure the flexure strength to melt or permeate the Alumina (Vita Zahnfabrik, Bad Sachkingen, Germany) of private used In-Cream and observe by Scanning election microscope. In the control group(3Y-TZP group), the average of flexure strength was 1623.7MPa, and in the experimental group(Glass-infiltrated 3Y-TZP group) was 1800.2MPa. As a result of observing the interface between glass and zirconia with a scanning election microscope, it was showed that the glass dissolves to permeate into the surface of zirconia, so filled the zirconia with particles.

  • PDF

익산지역 수원지의 불소함량에 관한 조사연구 (A Study on Fluoride Content in the Reservoirs Of Iksan Region)

  • 이인규
    • 대한치과기공학회지
    • /
    • 제20권1호
    • /
    • pp.139-143
    • /
    • 1998
  • This study was carried out to collect basic dates on fluoride intake from drinking water, and the apperance of mottled teeth after taking samples form 5 selected waterways from Iksan region's reservoir to the filtration plant for examination of the fluoride content. The results are as follows. 1. It indicatied that from Hoojung reservoir $2.17{\pm}0.95ppm$, Bulsan reservoir $1.93{\pm}0.23ppm$ and Yoolso reservoir $2.19{\pm}0.10ppm$. 2. Significances were found between Shinhung reservoir $2.57{\pm}1.22ppm$ and Uhwoo reservoir $0.80{\pm}0.55ppm$. 3. Except for the Uhwoo reservoir, the remaining 4 reservoir exceeded the standard fluoride content of 0.50-1.00ppm. For the residents in the region where they use natural water with fluoride content exceeding the standard 1.00ppm as their drinking water and the apperance of mottled teeth should be carried out.

  • PDF

비귀금속 합금을 이용한 주조체의 주조성과 Roughness에 관한 연구 (A Study on Castability and Roughness of the Casts Using Non-precious Alloys)

  • 김장주
    • 대한치과기공학회지
    • /
    • 제20권1호
    • /
    • pp.5-11
    • /
    • 1998
  • The purpose of this study is to evaluate the castability and surface roughness of the casts using Non-percious alloys. For samples of 25 wax patterns, it is made from eight layers of sheet wax, arranged in the escalating layers. After fabricated wax patterns, using 5 kinds of Ni-Cr alloys is casted, and the casts are sandblasted. To castability, magnifier is used and values of surface roughness of the casts is measured with profilometer(tracing length 1.75mm, cutoff value 0.25mm) The results are as follows : 1. The castanbility of alloys, in case of C alloys, showed with $8.0{\pm}0.0000$, and in case of CS alloys and N alloys showed equal with $7.8{\pm}0.4472$, respectively. T alloys and V alloys showed equal with $7.2{\pm}0.4472$, respectively. 2. The values of surface roughness of the casts are decreased more T alloys than in case of order alloys, and in order, increased in case of CS alloys, C alloys, V alloys, N alloys, respectively.

  • PDF

다공성 티타늄 임플란트 제조를 위한 분말 소결 (Powder Sintering for Fabrication of Porous Ti Implants)

  • 김영훈;이선경
    • 대한치과기공학회지
    • /
    • 제32권4호
    • /
    • pp.337-340
    • /
    • 2010
  • Purpose: This study was performed to compare sintering conditions for fabrication of porous Ti implant. Methods: The porous Ti implant samples were fabricated by sintering of spherical Ti powders in vacuum and atmosphere conditions. Surface morphology, composition and phase were analyzed by FE-SEM, EDX and XRD. Results: Sintered Ti implant in the vacuum consisted of particles connected in three dimensions by clear necking without excessive oxide layers. However, sintered Ti implant in atmosphere was formed excessive oxide layers with non-stoichiometric compounds. Conclusion: The porous Ti implant can be sintered in vacuum condition preferably.