• 제목/요약/키워드: Density analysis

검색결과 8,920건 처리시간 0.044초

가상공극개념을 이용한 연구자석의 전체전자기력과 상호체적력밀도 계산 (Evaluation of Global Force and Interaction Body Force Density in Permanent Magnet Employing Virtual Air-gap Concept)

  • 이세희
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.278-284
    • /
    • 2009
  • The global force and interaction body force density were evaluated in permanent magnets by using the virtual air-gap scheme incorporating the finite-element method. Until now, the virtual air-gap concept has been successfully applied to calculate a contact force and a body force density in soft magnetic materials. These force calculating methods have been called as generalized methods such as the generalized magnetic charge force density method, the generalized magnetizing current force density method, and the generalized Kelvin force density method. For permanent magnets, however, there have been few research works on a contact force and a force density field. Unlike the conventional force calculating methods resulting in surface force densities, the generalized methods are novel methods of evaluating body force density. These generalized methods yield the actual total force, but their distributions have an irregularity, which seems to be random distributions of body force density. Inside permanent magnets, however, a smooth pattern was obtained in the interaction body force density, which represents the interacting force field among magnetic materials. To evaluate the interaction body force density, the intrinsic force density should be withdrawn from the total force density. Several analysis models with permanent magnets were tested to verify the proposed methods evaluating the interaction body force density and the contact force, in which the permanent magnet contacts with a soft magnetic material.

상대밀도에 따른 구성모델의 토질매개변수 특성 (Characteristic of Soil Parameter of Constitutive Model by Relative Density)

  • 김찬기;조원범;박욱근;김의조;김용철
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.1117-1121
    • /
    • 2010
  • Several isotropic compression-expansion tests and a series of drained conventional traxial tests with various confining pressures for relative density of Beakma river sand 25%, 50%, 80% and 100% selecting Lade's Single Work-Hardening constitutive model. This examination materials use regression analysis as a basis, depending on the relative density of soil parameters change statement attributes. Yield fuction represent the soil parameters h and $\alpha$ is not affected by the changes in the relative density. $\eta_1$ could be replaced by fomula. And Numerical analysis results predicted very good and could confirm that.

  • PDF

패턴에 따른 층간절연막 CMP의 모델리에 관한 연구 (The Study on Pattern Dependent Modeling of ILD CMP)

  • 홍기식;정해도
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.1121-1124
    • /
    • 2001
  • In this study, we verify th effects of pattern density on interlayer dielectric chemical mechanical polishing process based on the analysis of Preston's equation and confirm this analysis by several experiments. Appropriate modeling equation, transformed form Preston's equations used in glass polishing, will be suggested and described the effects of this modeling during pattern wafer ILD CMP. Results indicate that the modeling is well agreed to middle density structure of the die in pattern wafer, but has some error in low and high density structure of the die. Actually, the die used in Fab, was designed to have a appropriate density, therefore this modeling will be suitable for estimating the results of ILD CMP.

  • PDF

물의 밀도 역전 현상을 고려한 수평 배관내의 자연대루 및 상변화 현상의 수치적 해석 (Numerical analysis of phase change inside horizontal pipe with consideration of density inversion effect of water)

  • 정기호;정수인;김귀순;하만영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1201-1206
    • /
    • 2004
  • This paper deals with the numerical analysis of natural convection flow induced by the density inversion effect of water inside horizontal pipe. The numerical method is based on SIMPLE/PWIM in general coordinate for its wide applicabilities. The numerical tool was validated through the comparison with the previous results concerning the density inversion effect of water It is shown that the developed numerical tool could predict the flow pattern and the heat transfer phenomena qualitatively And it is also found that the density inversion effect of water has significant effects on the flow pattern.

  • PDF

Interlaminar Flux Density Distribution at Joints of Overlapping Stacked Electrical Steel and Amorphous Ribbons

  • Erdem, Sezer;Derebasi, Naim
    • Journal of Magnetics
    • /
    • 제15권4호
    • /
    • pp.190-193
    • /
    • 2010
  • The design of joints in a transformer core significantly affects the transformer's efficiency. Air gaps cause variations in the flux distribution at the joints of the laminations, which depend on the geometry. Two similar samples consisting of electrical steel strips and amorphous ribbons were made. The spatial flux distributions were determined using an array of search coils for each sample. 2D models of these samples were created and examined by finite element analysis. The magnetic flux distribution for each lamination in the samples was computed. The results show that the flux density in amorphous ribbons above and below the air gap starts to approach saturation at lower flux density levels than for electrical steel. The flux density measured using the search coil under the air gap is increased in amorphous ribbons and decreased in the electrical steel with increasing frequency.

지하철 역사의 구조 및 특성을 고려한 동력부하밀도 분석 (Power Load Density Analysis considering Structure and Characteristics of Subway Stations)

  • 정현기;차광석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.912-920
    • /
    • 2006
  • The purpose of this study is to present the design standard for load density in subway station. From the data of electric equipment capacity and electric power consumption for 43 subway stations, current levels of the load density and excess capacity factor were surveyed and analyzed, In addition mean value, standard deviation, maximum value, median value and correlation coefficient were evaluated through excel program. Also it was carried out the regression analysis. The estimation method of load density and design criterion were studied. As a result, load density in this thesis have been proposed : 51.3 $[VA/m^2]$ on the general power load can be a standard value for subway station.

  • PDF

전자척에서 자속밀도 해석에 관한 연구 (Analysis of Magnetic Flux Density in Electro-Magnetic Chucks)

  • 김청균
    • 한국정밀공학회지
    • /
    • 제9권2호
    • /
    • pp.29-35
    • /
    • 1992
  • The distribution of magnetic flux density of electro-magnetic chucks may clarify the clamping characteristics which are strongly related to the machining efficiency and machining accuracy in a surface grinder. Therefore the distribution of the normal and the tangential components of magnetic flux density has been analyzed theoretically. It appears that the normal and the tangential components of magnetic flux density increase as the ratio of the separator width to the pitch e/p decreases. The results seem to increase the uniformity and stability of normal component of magnetic flux density for the decreased e/p.

  • PDF

LDPC 코드를 적용한 광 디스크 시스템의 에러 정정 성능 및 기록 용량 분석 (Analysis of error correction capability and recording density of an optical disc system with LDPC code)

  • 김기현;김현정;이윤우
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 신호처리소사이어티 추계학술대회 논문집
    • /
    • pp.537-540
    • /
    • 2003
  • In this paper, we evaluated error correction performance and recording density of an optical disc system. The performance of Low-Density Parity Check code (LDPC) is compared to the HD-DVD (BD) ECC. The recording density of optical disc can be increased by reducing the redundancy of the user data. Moreover, since the correction capability of LDPC with decreased redundancy is better than that of BD, the recording density can also be increased by reducing the mark length of the data on the disc surface.

  • PDF

마이크로파 레플렉토메터리를 이용한 KSIAR 플라즈마 밀도분포 재구성에 관한 연구 (Study on the Reconstruction of KSTAR Plasma Density Profiles Using Microwave Reflectometry)

  • 노영수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권8호
    • /
    • pp.365-370
    • /
    • 2005
  • Microwave diagnostics have been widely utilized to measure the important parameters of high temperature and high density plasmas. Reflectometry is known as a promising microwave diagnostic which has a number of merits to measure electron density profiles. In the KSTAR device, X-mode FM reflectometry is planned to measure the plasma density profiles. FM reflectometry is required to extract phase information on raw mixer IF signals, thereby obtaining time-of-flight of reflectometry signals. It is known that the data analysis method is crucial to determine the performance of FM reflectometry In fact, there are several analysis programs which have been utilized in various FM systems. Since each program was developed for a specific device, however, it is difficult to directly apply it to a different reactor like the KSTAR device. It is necessary, therefore, to develop a data analysis program for the KSTAR FM reflectometry. In this paper, complex digital demodulation (CDM) and wavelet transformation are examined in terms of the performance of density profile reconstruction. For the comparison of both methods, FM reflectometry signals are generated on the basis of assumed profiles and the interaction of the X-mode wave and the plasma. In order to see how well both methods work under various conditions, three types of profiles are assumed and noise effects are included. As a result, both methods work well under the condition of gentle density gradient and small noise level. As density gradient becomes steeper and noise level gets higher. the reconstruction performance of wavelet is better than that of CDM.

구획화재의 출입구를 통한 광학적 연기밀도 측정의 불확실성 해석 (Uncertainty Analysis of the Optical Smoke Density Measurement through the Doorway in a Compartment Fire)

  • 김성찬
    • 한국화재소방학회논문지
    • /
    • 제27권2호
    • /
    • pp.75-79
    • /
    • 2013
  • 본 연구는 구획화재의 출입구를 통한 연기밀도를 정량적으로 측정하고 측정기법의 신뢰성을 평가하기 위해 불확실성 해석을 수행한다. 메탄 화재 강도에 따른 축소모형 구획공간의 출입구 상층부를 통해 유출되는 연기 유동에 대해 광소멸 측정을 수행하고 Bouguer's의 법칙을 적용하여 연기밀도를 산정하였다. 광투과율, 경로길이, 질량비광소멸상수에 대하여 연기밀도의 측정 불확실도를 평가하였으며 계산된 연기밀도 측정의 확장불확실도는 20% 정도이며 신뢰수준은 95% 이다. 준정상상태의 화재 발열량에 대하여 출입구에서의 평균 연기밀도를 산정하였으며 구획공간내부의 총괄당량비 증가에 따라 출입구의 연기농도가 선형적으로 증가하는 경향을 보였다.