• 제목/요약/키워드: Decoupling controller$H_{2}$ design

검색결과 9건 처리시간 0.027초

Optimal $H_{2}$ design of the one-degree-of-freedom decoupling controllers

  • Park, Ki-Heon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2093-2098
    • /
    • 2005
  • In this paper, $H_{2}$ designs for the one-degree-of-freedom decoupling control systems are treated for the generalized plant. The optimal $H_{2}$ controller is obtained together with the ones that yield finite $H_{2}$ cost functions under compact assumptions. It is shown that the optimal closed transfer matrix is strictly proper under the reasonable order assumptions on the generalized plant.

  • PDF

LMI기법을 이용한 정방 비결합 제어기의 $H_2$설계 ($H_2$ Design for the Square Decoupling Controllers Using LMI Method)

  • 이종성;강기원;조용석;박기헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2645-2647
    • /
    • 2000
  • This paper presents an LMI(Linear Matrix Inequalities) method for designing the optimal decoupling controller. The proposed controller based on the Two-Degree-of-Freedom configuration considers both the performance of controller and decoupling properties. The decoupling controller parameters are obtained from LMI method for computational efficiency.

  • PDF

$H_2$ 기법을 이용한 2자유도 표준 모델의 정방 비결합 제어기 설계 ($H_2$ Design of the Square Decoupling Controller based on the Two-Degree-of-Freedom Standard Model)

  • 최군호;조용석;박기헌
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권8호
    • /
    • pp.980-986
    • /
    • 1999
  • In this paper, the optimal controller which decouples a coupled multivariable system and minimizes a quadratic performance index is proposed. Design of the controller is based on the two-degree-of-freedom standard model. The class of all stabilizing and decoupling controllers is parametrized first and the $H^{2}$optimal controller is obtained by using this parametrized form. An illustrative example for a $2{\times}2$ plant is given.

  • PDF

LMI 기법을 이용한 2자유도 표준모델에 대한 비결합 제어기의 $H_2$ 설계 ([ $H_2$ ]Design for Decoupling Controllers Based on the Two-Degree-of-Freedom Standard Model Using LMI Methods)

  • 이종성;강기원;박기헌
    • 전자공학회논문지SC
    • /
    • 제38권1호
    • /
    • pp.14-26
    • /
    • 2001
  • 본 논문에서는 다변수 시스템을 제어하는 경우 효율적인 제어를 어렵게 만드는 입력과 출력 사이의 결합 효과를 제거하는 비결합 제어기를 설계하였다. 설계된 제어기는 비결합 조건뿐만 아니라 제어계의 성능을 동시에 고려할 수 있는 2자유도 구조를 가지고 있다. 또한 제어기의 계산을 용이하게 하기 위하여 플랜트를 표준모델로 확장시킨 후 전달 행렬을 상태공간 계수로 표현하였다. 그리고 제어기의 계수값들은 선형 행렬 부등식을 이용하여 블록꼴 최적화 문제로 설정하여 구했기 때문에 비결합 및 성능 최적화에 초점을 둔 비결합 제어기의 $H_2$ 설계를 하는데 있어 효과적인 방법을 제시하였다.

  • PDF

LMI 기법을 이용한 2자유도 표준모델에 대한 비결합 제어기의 H(sub)$\infty$ 설계 (H(sub)$\infty$ Design for Decoupling Controllers Based on the Two-Degree-of-Freedom Standard Model Using LMI Methods)

  • 강기원;이종성;박기헌
    • 제어로봇시스템학회논문지
    • /
    • 제7권3호
    • /
    • pp.183-192
    • /
    • 2001
  • In this paper, the decoupling H(sub)$\infty$ controller which minimizes the maximum energy in the output signal is designed to reduce the coupling properties between the input/output variables which make it difficult to control a system efficiently. The state-space formulas corresponding to the existing transfer matrix formulas of the controller are derived for computational efficiency. And for a given decoupling $H_{\infty}$ problem, an efficient method are sought to find the controller coefficients through the LMI(Linear Matrix Inequalities) method by which the problem is formulated into a convex optimization problem.

  • PDF

H2 Design of Decoupled Control Systems Based on Directional Interpolations

  • Park, Kiheon;Kim, Jin-Geol
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1551-1558
    • /
    • 2013
  • $H_2$ design of decoupled control systems is treated in the generalized plant model. The existence condition of a decoupling controller is stated and a parameterized form of all achievable decoupled closed loop transfer matrices is presented by using the directional interpolation approaches under the assumption of simple transmission zeros. The class of all decoupling controllers that yield finite cost function is obtained as a parameterized form and an illustrative example to find the optimal controller is provided.

유전 알고리즘을 이용한 정방 비결합 제어기의 $H_{\infty}$ 설계 ([ $H_{\infty}$ ] Design for Square Decoupling Controllers Using Genetic Algorithm)

  • 이종성
    • 대한전자공학회논문지TE
    • /
    • 제42권4호
    • /
    • pp.47-52
    • /
    • 2005
  • 본 논문에서는 다변수 제어시스템 설계시 효과적인 제어를 어렵게 만드는 요인 중의 하나인 입력과 출력의 결합문제를 해결하기 위해서 각 채널의 출력변수는 대응되는 입력 신호에 의해서만 독립적으로 조정되도록 하는 비결합 제어기를 설계하였다. 설계된 제어기는 비결합 조건뿐만 아니라 제어계의 강인성을 동시에 고려할 수 있는 특성을 2자유도 구조에 적용하였다. 또한 제어기를 구하는 경우 계산을 용이하게 하기 위해서 플랜트를 표준모델로 확장시킨 후 전달행렬을 이용하여 상태공간계수로 표현하였다. 이 경우 비결합제어기의 자유매개변수를 구하는데 있어서 지능형탐색방법의 일종인 유전알고리즘을 적용하였다. 일반적으로 유전알고리즘을 특정한 문제에 적용할 경우 그 문제가 가지고 있는 최적화 특징을 잘 파악하여 이것을 이용하는 것이 유전알고리즘 적용시 성공여부를 결정하는 중요한 요인이 된다. 따라서 본 논문에서는 유전알고리즘을 이용하여 고정 차수의 정방 비결합제어기의 $H_{\infty}$설계시 효율적인 방법을 제시하였다.

$H_2$ 제어 기법을 이용한 Decoupling 제어기 설계 ($H_2$ controller Design of Decoupled Multivariable Feedback Control Systems)

  • 최군호;조용석;박기헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.460-462
    • /
    • 1998
  • In this study, we deal with a multivariable system which its input and output are coupled. This study presents a method for designing a controller which allows a coupled system to be transformed to a decoupled system in a standard model adopting 2DOF controller. And Wiener-Hopf($H_2$) approach is used so that the designed controller can minimize given cost function.

  • PDF

Voltage Balance Control of Cascaded H-Bridge Rectifier-Based Solid-State Transformer with Vector Refactoring Technology in αβ Frame

  • Wong, Hui;Huang, Wendong;Yin, Li
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.487-496
    • /
    • 2019
  • For a solid-state transformer (SST), some factors, such as signal delay, switching loss and differences in the system parameters, lead to unbalanced DC-link voltages among the cascaded H-bridges (CHB). With a control method implemented in the ${\alpha}{\beta}$ frame, the DC-link voltages are balanced, and the reactive power is equally distributed among all of the H-bridges. Based on the ${\alpha}{\beta}$ frame control, the system can achieve independent active current and reactive current control. In addition, the control method of the high-voltage stage is easy to implement without decoupling or a phase-locked loop. Furthermore, the method can eliminate additional current delays during transients and get the dynamic response rapidly without an imaginary current component. In order to carry out the controller design, the vector refactoring relations that are used to balance DC-link voltages are derived. Different strategies are discussed and simulated under the unbalanced load condition. Finally, a three-cell CHB rectifier is constructed to conduct further research, and the steady and transient experimental results verify the effectiveness and correctness of the proposed method.