• Title/Summary/Keyword: Data leakage

Search Result 1,078, Processing Time 0.028 seconds

Correlation between contrast leakage period of procedural rupture and clinical outcomes in endovascular coiling for cerebral aneurysms

  • Sung-Tae Kim;Sung-Chul Jin;Hae Woong Jeong;Jin Wook Baek;Young Gyun Jeong
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.4
    • /
    • pp.420-428
    • /
    • 2023
  • Objective: Intraprocedural rupture (IPR) is a fatal complication of endovascular coiling for cerebral aneurysms. We hypothesized that contrast leakage period may be related to poor clinical outcomes. This study aimed to retrospectively evaluate the relationship between clinical outcomes and contrast leakage period. Methods: Data from patients with cerebral aneurysms treated via endovascular coiling between January 2010 and October 2018 were retrospectively assessed. The enrolled patient's demographic data, the aneurysm related findings, endovascular treatment and IPR related findings, rescue treatment, and clinical outcome were analyzed. Results: In total, 2,859 cerebral aneurysms were treated using endovascular coiling during the study period, with IPR occurring in 18 (0.63 %). IPR occurred during initial frame coiling (n=4), coil packing (n=5), stent deployment (n=7), ballooning (n=1), and microcatheter removal after coiling (n=1). Tear sites included the dome (n=14) and neck (n=4). All IPRs were controlled and treated with coil packing, with or without stenting. Flow arrest of the proximal balloon was not observed. Temporary focal neurological deficits developed in two patients (11.1%). At clinical follow-up, 14 patients were classified as modified Rankin Scale (mRS) 0, three as mRS 2, and one as mRS 4. The mean contrast leakage period of IPR was 11.2 min (range: 1-31 min). Cerebral aneurysms with IPR were divided into late (n=9, mean time: 17.11 min) and early (n=9, mean time: 5.22 min) control groups based on the criteria of 10 min of contrast leakage period. No significant between-group differences regarding clinical outcomes were observed after IPR (p=1). Conclusions: In our series, all patients with IPR were controlled with further coil packing or stenting without proximal balloon occlusion within 31 min of contrast leakage. There was no difference in clinical outcomes when the long contrast leakage period group and short contrast leakage period group were compared.

A Study on Improvement Plans for Technology Protection of SMEs in Korea (중소기업 기술보호 개선방안에 대한 연구)

  • Lee, Jang Hoon;Shin, Wan Seon;Park, Hyun Ju
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.2
    • /
    • pp.77-84
    • /
    • 2014
  • The purpose of this research is to identify and develop technology protection plans for small and medium-sized enterprises (SMEs) by analyzing past technology leakage patterns which were experienced by SMEs. We identified factors which affect the technology leakage, and analyzed patterns of the influences using a data mining algorithms. A decision tree analysis showed several significant factors which lead to technology leakage, so we conclude that preemptive actions must be put in place for prevention. We expect that this research will contribute to determining the priority of activities necessary to prevent technology leakage accidents in Korean SMEs. We expect that this research will help SMEs to determine the priority of preemptive actions necessary to prevent technology leakage accidents within their respective companies.

The Study of Leakage Current Distributions of Plymeric Insulators will Changing Environment (주위 환경 변화 따른 폴리머 절연재료의 표면 누설전류)

  • 이병성;한재홍;김주용;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.88-91
    • /
    • 2001
  • Our knowledge about their long-term performance in an outdoor environment is still very limited. The electrical stress caused the surface of these insulators to become degradation. In order to evaluate leakage current patterns caused by surface aging on polymeric insulators, we utilized the combined aging test facility and leakage current monitoring system. And we get the continuous leakage current values from each sample. After completing the 3000h combined aging cycle test, leakage current measurement were conducted for these samples and carried out harmonics analysis for its data.

  • PDF

Performance Assessment of Turbulence Models for the Prediction of Tip Leakage Flow in an Axial-flow Turbomachinery (축류형 유체 기계에서 팁 누설 유동 해석을 위한 난류 모델 성능 비교)

  • Lee, Gong-Hee;Baek, Je-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2162-2167
    • /
    • 2003
  • It is well-known that high anisotropic characteristic of turbulent flow field is dominant inside tip leakage vortex. This anisotropic nature of turbulence invalidates the use of the conventional isotropic eddy viscosity turbulence model based on the Boussinesq assumption. In this study, to check whether an anisotropic turbulence model is superior to the isotropic ones or not, the results obtained from steady-state Reynolds averaged Navier-Stokes simulations based on the RNG ${\kappa}-{\varepsilon}$ and the Reynolds stress model in two test cases, such as a linear compressor cascade and a forward-swept axial-flow fan, are compared with experimental data. Through the comparative study of turbulence models, it is clearly shown that the Reynolds stress model, which can express the production term and body-force term induced by system rotation without any modeling, should be used to predict the complex tip leakage flow, including the locus of tip leakage vortex center, quantitatively.

  • PDF

A Study on the Low Level Leakage Currents of Silicon Oxides (실리콘 산화막의 저레벨 누설전류에 관한 연구)

  • 강창수;김동진
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.1
    • /
    • pp.29-32
    • /
    • 1998
  • The low level leakage currents in silicon oxides were investigated. The low level leakage currents were composed of a transient component and a do component. The transient component was caused by the tunnel charging and discharging of the stress generated traps nearby two interfaces. The do component was caused by trap assisted tunneling completely through the oxide. The low level leakage current was proportional to the number of traps generated in the oxides. The low level leakage current may be a trap charging and discharging current. The low level leakage current will affect data retention in EEPROM.

  • PDF

A Study on Fault Diagnosis of Boiler Tube Leakage based on Neural Network using Data Mining Technique in the Thermal Power Plant (데이터마이닝 기법을 이용한 신경망 기반의 화력발전소 보일러 튜브 누설 고장 진단에 관한 연구)

  • Kim, Kyu-Han;Lee, Heung-Seok;Jeong, Hee-Myung;Kim, Hyung-Su;Park, June-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.10
    • /
    • pp.1445-1453
    • /
    • 2017
  • In this paper, we propose a fault detection model based on multi-layer neural network using data mining technique for faults due to boiler tube leakage in a thermal power plant. Major measurement data related to faults are analyzed using statistical methods. Based on the analysis results, the number of input data of the proposed fault detection model is simplified. Then, each input data is clustering with normal data and fault data by applying K-Means algorithm, which is one of the data mining techniques. fault data were trained by the neural network and tested fault detection for boiler tube leakage fault.

A Feasibility Study on the Detection of Water Leakage using a Ground-Penetrating Radar (지하 탐사 레이더를 이용한 누수탐지 가능성 연구)

  • 오헌철;조유선;현승엽;김세윤
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.6
    • /
    • pp.616-624
    • /
    • 2003
  • The exhaustion of our water resource due to the leakage of waterworks renders it urgent to detect water leakage effectively. In the paper, the detection of water leakage makes use of a pound-penetrating radar(GPR). The region of water leakage is implemented by an acryl box filled with methanol, and then the scale-down experiments are performed by using the GPR system developed in our laboratory. The validity of GPR experiments is assured by showing that the measured data agree well with those finite-difference time-domain(FDTD) simulated results in the same situation. The feasibility of GPR system for the detection of water leakage is investigated by displaying B-scan images according to the distribution of water leakage.

EU ETS 실시 이후 탄소누출 가능성 산정 연구

  • Kim, Su-Lee
    • Environmental and Resource Economics Review
    • /
    • v.21 no.3
    • /
    • pp.519-542
    • /
    • 2012
  • In this paper, we empirically analyzed whether carbon leakage really happened in EU by comparing before and after the period of EU ETS. We regarded foreign direct investment outflows as indicator of carbon leakage and analyzed panel regression between production cost including environment cost and this FDI variable. Also we consider foreign market potential to analyze market oriented FDI. According to this analysis, carbon leakage was observed in some models for manufacturing industry. However carbon leakage did not prove consistently in a variety of models and it is hard to speak carbon leakage was happened in EU ETS. Notwithstanding relatively short time series of data, in the view of the fact that carbon leakage was tested in some models, Korea also should keep in mind the possibility of carbon leakage and design emission trading scheme.

  • PDF

Internal and External Factors of Knowledge Leakage Intention: From Tacit Knowledge Perspective (지식유출 의도의 내재적 및 외재적 요인에 대한 연구: 암묵적 지식 관점에서)

  • Kim, Yong-Tae;Koo, Yunmo;Lee, Jae-Nam
    • Knowledge Management Research
    • /
    • v.20 no.4
    • /
    • pp.75-97
    • /
    • 2019
  • In the rapidly changing business environment, knowledge has been recognized as a core asset for sustaining an organization's competitive advantage. In addition, knowledge sharing is one of the key elements of knowledge management, emphasizing external knowledge sharing beyond initial internal knowledge sharing. However, while knowledge management research emphasizes knowledge sharing, which is a positive aspect, research on preventing knowledge leakage that can have negative consequences is relatively lacking. Companies have tried to minimize the negative effects of knowledge management but many knowledge leakage accidents are still occurring. Therefore, this study aims to examine the effects of external factors based on deterrence theory and internal factors based on self-determination theory on knowledge leakage intention focusing on tacit knowledge. The results of the empirical analysis of 100 data sets collected through a scenario-based survey show that certainty of sanctions, social disapproval, and competence are found to have a significant effect on reducing tacit knowledge leakage intention. Furthermore, informal sanctions have a greater impact on tacit knowledge leakage intention than formal sanctions and external factors have a greater effect on tacit knowledge leakage intention than internal factors.

The Effectiveness Analysis of the Resistive Leakage Current Monitoring by Analyzing the Phase of the Body Current (인체 통전전류 위상 분석을 통한 저항성 누설전류 감시의 유효성 분석)

  • Kim, Jae-Hyun;Lim, Young-Bea;Lee, Sang-Ick;Kim, Dong-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.90-99
    • /
    • 2013
  • To analyze the effectiveness of the resistive leakage current monitoring as a technology preventing electrical accidents, in this paper, we have estimated the phase of the body impedance by using the body impedance model and the body impedance data from IEC. We also have analyzed the phase of the electric body current in the case of 60Hz/220V. From these results, we concluded that deliberate researches about the phase of the electrical body current and related regulations must be carried out before the resistive leakage current monitoring unit is used to protect electric shock. And we concluded that the resistive leakage current monitoring unit can be utilized to prevent electrical fires caused by electric leakage current without unwanted circuit break due to capacitive leakage current flowing from line filter capacitors to the earth.