• Title/Summary/Keyword: Data Acquisition system

Search Result 2,085, Processing Time 0.031 seconds

Biological Signal Measurements in SiMACS (SiMACS에서의 생체신호 수집)

  • Lim, J.J.;Choi, Y.S.;Kim, D.H.;Kim, E.J.;Lee, H.J.;Woo, E.J.;Park, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.05
    • /
    • pp.53-56
    • /
    • 1994
  • We have developed biological signal measurement modules and data acquisition and control card for a biological signal measurement, archiving, and communication system (SiMACS). Biological signals included in this system are ECG, EEG, EMG, invasive blood pressure, respiration, and temperature. Parameters of each module can be controlled by PC-base IDPU (intelligent data processing unit) through a data acquisition and control card. The data acquisition and control card can collect up to 16 channels of biological signals with sampling rate of $50\;{\sim}\;2,000Hz$ and 12-bit resolution. All measurement moduls and data acquisition functions are controlled by microcontroller which receives commands from PC. All data transfers among PC, microcontroller, and ADC are done through a shared RAM access by polling method for real rime operation.

  • PDF

Development of Portable Cadiovascular Signal Analysis System (휴대형 심혈관 신호해석장치의 개발)

  • Lee, D.J.;Lee, J.W.;Kim, H.S.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.663-665
    • /
    • 1998
  • The purpose of this paper is development of portable cardiovascular signal processing device. Beat-to-beat fluctuation in heart rate, respiration, and blood pressure have been known to be meditated by autonomic nervous system activities convergent on various effector organs. This system consists of data acquisition module, main data processing module and graphic LCD module. The data acquisition module is developed for data aquisition, data multiplexing and interfacing with main data processing system. And, main data processing module is developed for data storing, data processing and interfacing with graphic LCD module. The main processing system is based on 32-bit microprocessor.

  • PDF

Development of Unified SCADA System Based on IEC61850 in Wave-Offshore Wind Hybrid Power Generation System (파력-해상풍력 복합발전시스템의 IEC61850기반 통합 SCADA시스템 개발)

  • Lee, Jae-Kyu;Lee, Sang-Yub;Kim, Tae-Hyoung;Ham, Kyung-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.811-818
    • /
    • 2016
  • This paper suggests a structure of power control system in floating wave-offshore wind hybrid power generation system. We have developed an unified SCADA(Supervisory Control and Data Acquisition) system which can be used to monitor and control PCS(Power Conversion System) based on IEC61850. The SCADA system is essential to perform the algorithm like proportional distribution and data acquisition, monitoring, active power, reactive power control in hybrid power generation system. IEC61850 is an international standard for electrical substation automation systems. It was made to compensate the limitations of the legacy industrial protocols such as Modbus. In order to test the proposed SCADA system and algorithm, we have developed the wind-wave simulator based Modbus. We have designed a protocol conversion device based on real-time Linux for the communication between Modbus and IEC61850. In this study, SCADA system consists of four 3MW class wind turbines and twenty-four 100kW class wave force generator.

An integrated structural health monitoring system for the Xijiang high-speed railway arch bridge

  • He, Xu-hui;Shi, Kang;Wu, Teng
    • Smart Structures and Systems
    • /
    • v.21 no.5
    • /
    • pp.611-621
    • /
    • 2018
  • Compared with the highway bridges, the relatively higher requirement on the safety and comfort of vehicle makes the high-speed railway (HSR) bridges need to present enhanced dynamic performance. To this end, installing a health monitor system (HMS) on selected key HSR bridges has been widely applied. Typically, the HSR takes fully enclosed operation model and its skylight time is very short, which means that it is not easy to operate the acquisition devices and download data on site. However, current HMS usually involves manual operations, which makes it inconvenient to be used for the HSR. Hence, a HMS named DASP-MTS (Data Acquisition and Signal Processing - Monitoring Test System) that integrates the internet, cloud computing (CC) and virtual instrument (VI) techniques, is developed in this study. DASP-MTS can realize data acquisition and transmission automatically. Furthermore, the acquired data can be timely shared with experts from various locations to deal with the unexpected events. The system works in a Browser/Server frame so that users at any places can obtain real-time data and assess the health situation without installing any software. The developed integrated HMS has been applied to the Xijiang high-speed railway arch bridge. Preliminary analysis results are presented to demonstrate the efficacy of the DASP-MTS as applied to the HSR bridges. This study will provide a reference to design the HMS for other similar bridges.

Radiation image mapping system (방사선 영상 매핑 장치)

  • 최영수;박순용;이종민
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1884-1887
    • /
    • 1997
  • The increasing concern over radiation exposure in the nuclear industry has fostered agrressive efforts to reduce the levels of radiation exposure. One area of the effot to reduce the radiation exposure is the development of a remote radiation monitoring system. Remote radiation monitoring can serve many benificaial functions reduce exposure to radiation by plant personnel, impruve the quality of the data that is collected and recognize the radiation environment easily. Radiation mapping system gives a good information that represents radiation level distribution. The system we have developed consists of a data acquistion parts, mobile robot and remote control parts. Data acquisition parts consist of radiation detection module and vision acquistion module which collect radiation data, visiion data and distance information. In remote control parts, the acquision data are processed and displayed. We have constructed radiation mapping image by overlaying the vision and radiation data. The radiation mapping techniques for displaying the results of the survey in an easily comprehendable form will facilitate a better understanding of the radiation environment in the facility. This system can reduce workers radiation exposure and aid to help work plan, so it has significant benifits in cost and safety.

  • PDF

Design and Implementation of a Hybrid Equipment Data Acquisition System(HEDAS) for Equipment Engineering System(EES) Framework (EES 프레임워크를 위한 하이브리드 생산설비 데이터 습득 시스템(HEDAS)의 설계 및 구현)

  • Kim, Gyoung-Bae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.2
    • /
    • pp.167-176
    • /
    • 2012
  • In this paper we design and implement a new Hybrid Equipment Data Acquisition System (HEDAS) for data collection of semiconductor and optoelectronic manufacturing equipments in the equipment engineering system(EES) framework. The amount of the data collected from equipments have increased rapidly in equipment engineering system. The proposed HEDAS efficiently handles a large amount of real-time equipment data generated from EES framework. It also can support the real-time ESS applications as well as non real-time ESS applications. For the real-time EES applications, it performs high-speed real-time processing that uses continuous query and filtering techniques based on memory buffers. The HEDAS can optionally store non real-time equipment data using a HEDAS-based database or a traditional DBMS-based database. In particular, The proposed HEDAS offers the compression indexing based on the timestamp of data and query processing technique saving the cost of disks storage against extremely increasing equipment data. The HEDAS is efficient system to collect huge real-time and non real-time equipment data and transmit the collected equipment data to several EES applications in EES framework.

Development of Mobile System for Field Data Acquisition based on CompactFlash Card (CompactFlash 카드 기반의 필드 데이터 수집을 위한 모바일 시스템의 개발)

  • Seo, Jung-Hee;Park, Hung-Bog
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.7
    • /
    • pp.1693-1700
    • /
    • 2010
  • Field data acquisition is faster in PDA-based mobile environment compared with document-based data acquisition, ensuring accurate data acquisition. However, portable DAQ systems of mobile environment can effectively replace DAQ systems embedded in computers but are less capable than DAQ systems embedded in computers and usually used in environments different from computers, causing noises whose cause are characteristics not certainly known. Therefore, in order to collect mobile-based field data, CompactFlash card-based hardware prototypes are suggested and mobile applications which guarantee acquisition of large amount of data with low hardware capability are performed. According to the test, mobile environments such as PDA were proved to be an effective way of collecting large amount of data. However, hardware performance has major effects on sequential data acquisition in mobile environments regardless of data display.

Feasibility Study of Data Acquisition System based on Oscilloscope for Radiation Detector (방사선 검출기용 데이터획득장치로서의 오실로스코프 활용 가능성 평가)

  • Yang, Jingyu;Kang, Jihoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1804-1809
    • /
    • 2017
  • A data acquisition (DAQ) system based on oscilloscope was developed and evaluated for radiation detector. The dedicated LabVIEW program that perform the oscilloscope control and the data process was developed. Triggered events for each analog channel were acquired and the output signals were subsequently digitized and recorded for offline processing. Radiation pulse generation circuit was developed to evaluate the intrinsic characteristics of DAQ system. Energy linearity and energy resolution performances were assessed by voltage-peak channels and FWHM obtained from Gaussian fit, respectively. Radiation detector consists of LYSO and GAPD array. The 16 output signals were multiplexed by the RCD networks, and they were fed into the custom-made preamplifiers. Voltage-peak channels was linearly changed as a function of input voltage and the estimated coefficient of determination ($R^2$) was 0.999. No considerable changes in voltage resolution were observed. All 16 crystals were clearly identifiable on the resulting flood image and the mean energy resolution was ~15.1%. This study demonstrated that it is feasible to develop the DAQ system based on oscilloscope and LabVIEW program for radiation detector and the proposed approach offers opportunities to build simple DAQ system in various radiation measurement field.

Implementation of Data Monitoring and Acquisition System for Real-time Rotating Machinery based on oneM2M (oneM2M 표준 기반 실시간 회전기기 센싱 데이터 수집 및 모니터링 시스템 구현)

  • Lee, Young-Dong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.1
    • /
    • pp.57-62
    • /
    • 2019
  • In this paper, oneM2M based data monitoring and acquisition system is designed and implemented to measure and transmit the voltage, current, temperature, acceleration and vibration of the motor. The proposed system can detect electrical faults (overcurrent, reverse phase, phase loss, ground fault) and mechanical faults (MC counter, motor operation time, bearing and winding temperature, motor speed, insulation resistance). The system consists of sensor data collection, web server, php, database, wired/wireless communication system. The insulation resistance and the motor speed were measured, and the experimental results were similar for both the test resistance value and the reference input value.