• Title/Summary/Keyword: DEGRADATION

Search Result 13,722, Processing Time 0.04 seconds

A Study on the Dielectric Degradation Using Partial Discharge System (부분방전 시스템을 이용한 절연 열화에 관한 연구)

  • 김성홍;이우상;정재용
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.1
    • /
    • pp.1-6
    • /
    • 1998
  • Our studies diagnose insulation degradation using the method of PD system. In analysis method of degradation, we make use of degradation information that analyzed the phase angle - PD pulse amplitude - degradation time( $\Phi$- PDA - t) pattern and phase angle- PD pulse number - degradation time( $\Phi$- PDN - t) pattern using statistical operators such as skewness(S), kurtosis(K). Secondly using statically operator such as the center of gravity (G), the gradient of the discharge distribution(C), we have analyzed for the prediction of life which we can be obtained the time, occurred of many pulse of small discharge amplitude.

  • PDF

Reaction Conditions for Laccase Catalyzed Degradation of Bisphenol A

  • Kim, Young-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.2
    • /
    • pp.79-83
    • /
    • 2004
  • The oxidative degradation of BPA with laccase from Trametes versiclor was conducted in a closed, temperature controlled system containing acetate buffer for pH control. The effects of medium pH, buffer concentration, temperature and mediator on degradation of BPA were investigated. The inactivation of the enzyme by temperature and reaction product was also studied. The optimal pH for BPA degradation showed about 5. Buffer concentration did not affect BPA degradation. On the other hand, the enzyme stability was higher at low concentration buffer(25 mM). Temperature rise increased the degradation rate of BPA up to 45$^{\circ}C$. The valuable mediator of laccase for BPA was ABTS. Elevated temperature and reaction product irreversibly inactivated the enzyme.

Continuous Degradation of Formaldehyde by Peudomonas putida H-5 Using Rotation Disc Contactor (회전원판반응조에 의한 Peudomonas putida H-5의 포름알데히드의 연속적 분해)

  • 류병호;임복규
    • KSBB Journal
    • /
    • v.8 no.1
    • /
    • pp.42-48
    • /
    • 1993
  • Continuous degradation of formaldehyde by using a rotating disc contactor was investigated in this study. Peudomonas putida H-5K was selected as a mutant using N-methyl N'-nitro N-nitrosoguandine (250$\mu\textrm{g}$/$m\ell$), which showed 1.5 times higher ability of formaldehyde degradation than that of the parent strain. Enzyme activity for formaldehyde degradation released form Peudomonas putida H-5K showed the highest level of 6.2mo1/min/mg protein in the 2% glucose mineral medium containing 0.02% formaldehyde. Degradation of formaldehyde from the first stage in rotating disc contactor was 95% and 5% from the 4th stage when the reactor was fed with 0.02% or 0.04% formaldehyde solution at a rate of 20$m\ell$ per hour. Continuous degradation of formaldehyde using rotating disc contactor was above 95%o in the medium containing 0.04% formalchyde, at the medium feed ratc of 20$m\ell$ per hour.

  • PDF

Failure-Time Estimation from Nonlinear Random-Coefficients Model: PDP Degradation Analysis (PDP 열화분석 예제를 통한 랜덤계수모델에서의 고장시간분포 추정)

  • Bae, Suk-Joo;Kim, Seong-Joon
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2006.05a
    • /
    • pp.181-191
    • /
    • 2006
  • As an alternative to traditional life testing, degradation tests can be effective in assessing product reliability when measurements of degradation leading to failure can be observed. This article proposes a new model to describe the nonlinear degradation paths caused by nano-contamination for plasma display panels (PDPs) : a bi-exponential model with random coefficients. A sequential likelihood ratio test was executed to select random effects in the nonlinear model. Analysis results indicate that the reliability estimation can be improved substantially by using the nonlinear random-coefficients model to incorporate both inherent degradation characteristics and contamination effects of impurities for PDP degradation paths.

  • PDF

The Study of Degradation Mechanism as ZnO Varistor with The Ambient Sintering-Process (분위기 소결공정에 의한 ZnO 바리스터의 열화기구 연구)

  • 소순진;김영진;최운식;박춘배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.117-120
    • /
    • 1999
  • The relationship between the DC degradation characteristics of the ZnO varistor and the ambient sintering-process is investigated in this study. ZnO varistors made of Matsuoka's composition were fabricated by standard ceramic techniques. The ambient sintering-process is performed at the extraordinary electrical-furnace which is equipped with the vacuum system. The Gas of sintering process was oxygen, nitrogen, argon, air respectively. The microstructure of ZnO varistors be made use of SEM equipment. The condition of DC degradation tests were conducted at $115\pm2^{\circ}C$ for periods up to 13 h. Current-voltage analysis is used to determine nonlinear coefficients($\alpha$). Resistance-frequency and capacitance-frequency analysis are accomplished to the understanding of electrical properties as DC degradation test. From above analysis, it is found that the ZnO varistor sintered in oxygen atmosphere showed superior properties at the DC degradation test.

  • PDF

Realization of Static Image on OLEO using Photoluminescence Degradation (PL Degradation을 활용한 OLED 소자의 사진 이미지 구현)

  • Suh, Won-Gyu;Moon, Dae-Gyu
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.9
    • /
    • pp.859-862
    • /
    • 2008
  • We have realized static image on organic light emitting diodes (OLEDs) using photoluminescence degradation. Ultraviolet (UV) was irradiated to the glass side of device. UV power was 350 Wand the wavelength was 365 nm. The UV irradiation gives rise to the degradation of photoluminescence. Due to the degradation, the current density-voltage curve was shifted to the higher voltage side and the luminescence was also degraded by the current and photoluminescence drop. The negative imaged films were prepared to control the transmittance of UV. The UV light was passed through the film. By this method, the film image was transferred to the device with reversed image and the static image was realized on the OLED.

The characteristics research of lifetime degradation for LED Lighting System (LED가로등 열화특성 분석연구)

  • Lee, Se-Hyun;Yang, Seung-Yong;Hwang, Myung-Keun;Shin, Sang-Wuk;Rho, Jae-Yup;Choi, Seok-Joon;Lee, Jeong-Keun;Seo, Jeong-Jin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.149-152
    • /
    • 2009
  • In this paper, We has been studied the lifetime degradation of LED lighting system compared to MH lighting. Especially the effect of temperature level on the lifetime degradation has been investigated. The results show that temperature plays a role in the lifetime degradation and slope of degradation line represent as temperature level differently. However, It is possible to estimate the lifetime of LED lighting system using equation induced the slope of degradation line.

  • PDF

Analysis of degradation of distribution lightning arresters as degradation degree (열화정도에 따른 배전용 피뢰기의 열화특성 분석)

  • 장동욱;박동배;박영국;이용희;강성화;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.140-143
    • /
    • 2000
  • The primary function of ZnO lightning arrester is to protect transmission and distribution equipment from overvoltages and to absorb electrical energy resulting from lightning or switching surges and form temporary overvoltage. However, ZnO lightning arrester are known to exhibit an increases in resistive current with time, the rate of increase being exacerbated with increasing applied voltage and ambient temperature. So, it is important to the leakage current measurement of ZnO lightning arrester. In addition, since the resistive leakage current caused by deterioration of ZnO lightning arrester mainly caused an increase of the third harmonic component, thereby it is possible the arrester degradation diagnosis by measuring the third harmonic component in the total leakage current. The leakage current and third harmonic component are measured and used to investigate the degradation diagnosis of ZnO element of arrester. Also the SEM photography is used to investigate the change of crystal structure of ZnO element with degradation.

  • PDF

Variation in Microstrutures and Mechanical Properties During Long-term Material Degradation of Austenitic 316L Steel (오스테나이트계 316강의 장시간 재료 열화에 따른 미세조직의 변화와 기계적 특성의 변화)

  • Kong, Wonsik;Kim, Chungseok
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.34 no.6
    • /
    • pp.315-322
    • /
    • 2021
  • In this study, we investigate the variation in microstruture and mechanical property of austenitic 316L stainless steel during long-term material degradation. To simulate the material degradation, the AISI 316 steel was exposed to accelerate under a temperature of 600℃ for up to 10000 hours at each predetermined heat treatment time. As the long-term material degradation time increase, the grain shape was changed from polygonal grains with annealing twins to circular grains. Most twins distributed uniformly interior of grains are recovered and disappered with long-term material degradation. Also, the δ ferrite along grain boundaries decomposed and transformed into the σ phase resulting in decrease of elongation of austenitic 316L stainless steel.

Photo-Assisted Sondegradation of Hydrogels in the Presence of TiO2 Nanoparticles

  • Ebrahimi, Rajabali;Tarhandeh, Giti;Rafiey, Saeed;Narjabadi, Mahsa;Khani, Hamed
    • Journal of the Korean Chemical Society
    • /
    • v.56 no.1
    • /
    • pp.92-101
    • /
    • 2012
  • The degradation of one of the commercially important hydrogel based on acrylic acid and acryl amide, (acrylic acid-co-acryl amide) hydrogels, by means of ultrasound irradiation and its combination with heterogeneous ($TiO_2$) was investigated. 24 kHz of ultrasound irradiation was provided by a sonicator, while an ultraviolet source of 16 W was used for UV irradiation. The extent of sonolytic degradation increased with increasing ultrasound power (in the range 30-80 W). $TiO_2$ sonophotocatalysis led to complete (acrylic acid-co-acryl amide) hydrogels degradation with increasing catalyst loading, while, the presence of $TiO_2$ in the dark generally had little effect on degradation. Therefore, emphasis was totally on the sonolytic and sonophotocatalytic degradation of hydrogels and a synergy effect was calculated for combined degradation procedures (Ultrasound and Ultraviolet) in the presence of $TiO_2$ nanoparticles. $TiO_2$ sonophotocatalysis was always faster than the respective individual processes due to the enhanced formation of reactive radicals as well as the possible ultrasound-induced increase of the active surface area of the catalyst. A kinetics model based on viscosity data was used for estimation of degradation rate constants at different conditions and a negative order for the dependence of the reaction rate on total molar concentration of (acrylic acid-co-acryl amide) hydrogels solution within the degradation process was suggested.