• Title/Summary/Keyword: D-효율

Search Result 7,404, Processing Time 0.034 seconds

On Method for LBS Multi-media Services using GML 3.0 (GML 3.0을 이용한 LBS 멀티미디어 서비스에 관한 연구)

  • Jung, Kee-Joong;Lee, Jun-Woo;Kim, Nam-Gyun;Hong, Seong-Hak;Choi, Beyung-Nam
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.169-181
    • /
    • 2004
  • SK Telecom has already constructed GIMS system as the base common framework of LBS/GIS service system based on OGC(OpenGIS Consortium)'s international standard for the first mobile vector map service in 2002, But as service content appears more complex, renovation has been needed to satisfy multi-purpose, multi-function and maximum efficiency as requirements have been increased. This research is for preparation ion of GML3-based platform to upgrade service from GML2 based GIMS system. And with this, it will be possible for variety of application services to provide location and geographic data easily and freely. In GML 3.0, it has been selected animation, event handling, resource for style mapping, topology specification for 3D and telematics services for mobile LBS multimedia service. And the schema and transfer protocol has been developed and organized to optimize data transfer to MS(Mobile Stat ion) Upgrade to GML 3.0-based GIMS system has provided innovative framework in the view of not only construction but also service which has been implemented and applied to previous research and system. Also GIMS channel interface has been implemented to simplify access to GIMS system, and service component of GIMS internals, WFS and WMS, has gotten enhanded and expanded function.

  • PDF

Effects of Feeding Levels and Particle Size of Germanium Biotite on Pig Performance (돼지 생산성에 있어 게르마늄흑운모의 첨가수준 및 입자도의 효과)

  • Lee, W.B.;Kim, I.H.;Hong, J.W.;Kwon, O.S.;Min, B.J.;Shon, K.S.;Jung, Y.K.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.787-796
    • /
    • 2003
  • Two experiments were conducted to investigate the effect of germanium biotite (GB) on growth performance, nutrient digestibility and fecal gas emission in pigs. In Exp 1., a total of one hundred nursery pigs (initial body weight 13.12${\pm}$0.15kg) were used in a 21 d growth assay. The five treatments were control (CON, basal diet), GB0.5-200 (basal diet + 0.5% GB, 200mesh), GB1.0-200 (basal diet + 1.0% GB, 200mesh), GB0.5-325 (basal diet + 0.5% GB, 325mesh), GB1.0-325 (basal diet + 1.0% GB, 325mesh). Each treatment had four replicates with five pigs per replicate. ADG, ADFI and gain/feed were not significantly different among the treatments. Fecal NH3-N concentration of pigs fed the GB325 diet was lower than that of pigs fed the GB200 diet (P=0.01). The GB treatments reduced fecal volatile fatty acids significantly compared to the CON (propionic acid, P=0.01; butyric acid, P=0.01; acetic acid, P=0.02). Especially, fecal propionic acid concentration of pigs fed the GB325 diets was lower than that of pigs fed the GB200 diets (P=0.02). In Exp 2., a total of seventy five pigs (initial body weight 21.18${\pm}$0.15kg) were used in a 28 d growth assay. The treatments were same as described for Exp. 1. Each treatment had five replicates with three pigs per replicate. The GB1.0 treatments significantly increased the ADG compared to the GB0.5 treatments (P=0.03). The DM and N digestibility of pigs fed the GB1.0 diets were higher than that for pigs fed the GB0.5 diets (P=0.01). Also, the Ca digestibility of pigs fed the GB diets was higher than that for pigs fed the CON diets (P=0.01). The fecal NH3-N concentrations for the GB treatments were lower than that for the CON (P=0.01). The GB325 treatments significantly decreased the fecal NH3-N concentration compared to the GB200 treatments (P=0.03). The fecal butyric acid concentration for the GB325 treatments was lower than that for the GB200 treatment (P=0.04). In conclusion, the results obtained from these feeding trials suggest that the dietary GB for nursery pigs affects fecal noxious gas emission. In growing pigs, dietary GB was effective to improve ADG and decrease fecal noxious gas emission.

Analysis of Genetic Characteristics and Probability of Individual Discrimination in Korean Indigenous Chicken Brands by Microsatellite Marker (MS 마커를 이용한 토종닭 브랜드의 유전적 특성 및 개체 식별력 분석)

  • Suh, Sangwon;Cho, Chang-Yeon;Kim, Jae-Hwan;Choi, Seong-Bok;Kim, Young-Sin;Kim, Hyun;Seong, Hwan-Hoo;Lim, Hyun-Tae;Cho, Jae-Hyeon;Ko, Yeoung-Gyu
    • Journal of Animal Science and Technology
    • /
    • v.55 no.3
    • /
    • pp.185-194
    • /
    • 2013
  • Microsatellite markers have been a useful genetic tool in determining diversity, relationships and individual discrimination studies of livestock. The level of genetic diversity, relationships among two Korean indigenous chicken brand populations (Woorimatdag: WR, Hanhyup3: HH) as well as two pure populations (White Leghorn: WL, Rhode Island Red: RIR) were analyzed, based on 26 MS markers. A total of 191 distinct alleles were observed across the four chicken populations, and 47 (24.6%) of these alleles were unique to only one population. The mean $H_{Exp}$ and PIC were estimated as 0.667 and 0.630. Nei's $D_A$ genetic distance and factorial correspondence analysis (FCA) showed that the four populations represented four distinct groups. However, the genetic distance between each Korean indigenous chicken brand (WR, HH) and the pure population (WL, RIR) were threefold that among the WR and HH. For the STRUCTURE analyses, the most appropriate number of clusters for modeling the data was determined to be three. The expected probabilities of identity among genotypes of random individuals (PI) were calculated as $1.17{\times}10^{-49}$ (All 26 markers) and $1.14{\times}10^{-15}$, $7.33{\times}10^{-20}$ (9, 12 with the highest PI value, respectively). The results indicated that the brand chicken breed traceability system employing the own highest PI value 9 to 12 markers, and might be applicable to individual identification of Korean indigenous chicken brand.

Recirculating Integrated System for the Treatment of Authentic Integrated-textile-dyeing Wastewater from Dyeing Industrial Complex (염색산업단지 종합폐수처리용 재순환 통합시스템)

  • Lee, Eun Ju;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.837-845
    • /
    • 2017
  • A recirculating integrated system composed of a fluidized biofilter filled with waste-tire crumb media fixed with return sludge from wastewater treatment facility of D dyeing industrial center, and a UV/photocatalytic reactor packed with calcined $TiO_2$ coated-glass beads as photocatalyst-support, was constructed and was run to treat authentic textile-dyeing wastewater from D-dyeing industrial center, which was mixed with an alkaline polyester-weight-reducing wastewater and a wastewater from sizing process. As a result, its total removal efficiency(RE(tot)) of $COD_{cr}$ and colors were ca. 81% and 55%, respectively. The synergy effect of the recirculating integrated system to enhance total removal efficiency(RE(tot)) of $COD_{cr}$ and colors were evaluated at most ca. 7% and 3%, respectively. The fluidized biofilter and the UV/photocatalytic reactor were responsible for ca. 94% and 6% of the total $COD_{cr}$ removal efficiency, respectively, and were also responsible for ca. 86% and 14% of the total color-removal efficiency, respectively. Thus, the degree of the UV/photocatalytic reactor-unit process's contribution to RE(tot) of color, was about 2.4 times of that to RE(tot) of $COD_{cr}$. Therefore, the UV/photocatalytic reactor facilitated the more effective elimination of colors by breaking down the chemical bonds oriented from colors of dyes such as azo-bond, than $COD_{cr}$. In addition, the effect of the removal efficiency of each unit process(i.e., the fluidized biofilter or the UV/photocatalytic reactor) of the recirculating integrated system on RE(tot) of $COD_{cr}$ and colors, was analysed by establishing its model equation with an analytic correlation.

Effect of Cooling Water Capacity on the Engine Performance for Small Diesel Engine (냉각수(冷却水) 용량(容量)이 소형(小型) 디젤기관(機關)의 성능(性能)에 미치는 영향(影響))

  • Myung, Byung Soo;Kim, Soung Rai
    • Korean Journal of Agricultural Science
    • /
    • v.13 no.2
    • /
    • pp.265-278
    • /
    • 1986
  • This study was attempted to improve the thermal efficiency of 6 kW water-cooled diesel engine on power tiller. The engine performance tests were conducted to find out the effect of cooling water capacity of 2700cc, 2800cc, 2900cc, 3000cc, 3100cc on power, brake specific fuel consumption (BSFC), torque, temperature of cooling water and lubricating oil and friction losses of the engine with D. C. dynamometer. The results obtained in the study are summarized as follows: 1. The performance of the engine tested was adequated to Korea Industrial Standard but actual economy power was 10% higher than the labeled rated power of the engine. The BSFC of the engine tested 297.8g/kW-h which is belong a little higher level than hreign products. The temperature of cooling water was $101^{\circ}C$ which is higher than SAE standard ($88^{\circ}C$) 2. The friction losses of engine tested was 3.656 kW at 2200 rpm of rated rpm (piston speed 6.97m/sec) and is higher than those of foreign products. 3. When the cooling water capacity was increased from 2700cc to 3100cc the power output of the engine was increased from 6.7 kW to 7.13 kW at the rate of 6.4% and also the torque of the engine was increased from 28.85 N.m to 30.76 N.m at the rate of 6.39%. 4. When the cooling water capacity was increased from 2700cc to 3100cc, the BSFC was decreased 6.9g/kW-h from 310.9g/kW-h to 304.1g/kW-h, and after one half hour operation with full load, the temperature of cooling water was decreased $13^{\circ}C$ from $101^{\circ}C$ to $88^{\circ}C$ and also the temperature of lubricant oil was decreased $6.4^{\circ}C$ from $76.7^{\circ}C$ to $70.4^{\circ}C$. 5. The mechanical efficiency was increased from 70.08% to 71.08% when the cooling water capacity was increased from 2700cc to 3100cc.

  • PDF

Digital Hologram Compression Technique By Hybrid Video Coding (하이브리드 비디오 코팅에 의한 디지털 홀로그램 압축기술)

  • Seo, Young-Ho;Choi, Hyun-Jun;Kang, Hoon-Jong;Lee, Seung-Hyun;Kim, Dong-Wook
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.5 s.305
    • /
    • pp.29-40
    • /
    • 2005
  • According as base of digital hologram has been magnified, discussion of compression technology is expected as a international standard which defines the compression technique of 3D image and video has been progressed in form of 3DAV which is a part of MPEG. As we can identify in case of 3DAV, the coding technique has high possibility to be formed into the hybrid type which is a merged, refined, or mixid with the various previous technique. Therefore, we wish to present the relationship between various image/video coding techniques and digital hologram In this paper, we propose an efficient coding method of digital hologram using standard compression tools for video and image. At first, we convert fringe patterns into video data using a principle of CGH(Computer Generated Hologram), and then encode it. In this research, we propose a compression algorithm is made up of various method such as pre-processing for transform, local segmentation with global information of object image, frequency transform for coding, scanning to make fringe to video stream, classification of coefficients, and hybrid video coding. Finally the proposed hybrid compression algorithm is all of these methods. The tool for still image coding is JPEG2000, and the toots for video coding include various international compression algorithm such as MPEG-2, MPEG-4, and H.264 and various lossless compression algorithm. The proposed algorithm illustrated that it have better properties for reconstruction than the previous researches on far greater compression rate above from four times to eight times as much. Therefore we expect that the proposed technique for digital hologram coding is to be a good preceding research.

A Fluid Analysis Study on Centrifugal Pump Performance Improvement by Impeller Modification (원심펌프 회전차 Modification시 성능개선에 관한 유동해석 연구)

  • Lee, A-Yeong;Jang, Hyun-Jun;Lee, Jin-Woo;Cho, Won-Jeong
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.2
    • /
    • pp.1-8
    • /
    • 2020
  • Centrifugal pump is a facility that transfers energy to fluid through centrifugal force, which is usually generated by rotating the impeller at high speed, and is a major process facility used in many LNG production bases such as vaporization seawater pump, industrial water and fire extinguishing pump using seawater. to be. Currently, pumps in LNG plant sites are subject to operating conditions that vary depending on the amount of supply desired by the customer for a long period of time. Pumps in particular occupy a large part of the consumption strategy at the plant site, and if the optimum operation condition is not available, it can incur enormous energy loss in long term plant operation. In order to solve this problem, it is necessary to identify the performance deterioration factor through the flow analysis and the result analysis according to the fluctuations of the pump's operating conditions and to determine the optimal operation efficiency. In order to evaluate operation efficiency through experimental techniques, considerable time and cost are incurred, such as on-site operating conditions and manufacturing of experimental equipment. If the performance of the pump is not suitable for the site, and the performance of the pump needs to be reduced, a method of changing the rotation speed or using a special liquid containing high viscosity or solids is used. Especially, in order to prevent disruptions in the operation of LNG production bases, a technology is required to satisfy the required performance conditions by processing the existing impeller of the pump within a short time. Therefore, in this study, the rotation difference of the pump was applied to the ANSYS CFX program by applying the modified 3D modeling shape. In addition, the results obtained from the flow analysis and the curve fitting toolbox of the MATLAB program were analyzed numerically to verify the outer diameter correction theory.

A Study on the Estimation Measure of Delay Cost on Work Zone Using the Traffic Flow Model (교통류 모형을 이용한 도로 점용공사 구간의 지체비용 산정방안)

  • Kim, Yunsik;Lee, Minjae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.5
    • /
    • pp.120-129
    • /
    • 2016
  • The user cost is an important analysis item which should be considered together with life-cycle of facility, administrator cost and discount rate in LCCA for efficient asset management of SOC facilities. Especially, a significant delay cost occurs often for users in the road field due to a work zone for cleaning and maintenance, and in such case, the administrator should consider the administrator cost as well as the user cost for more rational decision making. However, the user cost has not been considered in most decision making steps until recently and relevant studies also have not been carried out actively. In this study, the methodology to estimate the user cost and delay cost required in the decision making step using the traffic flow model and the direct benefit estimation model in the traffic facility investment evaluation guideline is suggested. And, the traffic flow model was estimated on 4 national highway sections where maintenance was actually carried out in 2014 using VISSIM and, the user cost and the delay cost were estimated based on the suggested methodology. The analysis result showed that the average user cost of $17,569,000KRW/km{\times}day$ occurred on Section A with approximately 30,000 AADT before a work zone occurred, and in case the first lane was blocked for maintenance, the delay cost of $10,193,000KRW/km{\times}day$ (158%) on average occurred additionally. The delay cost of $1,507,000KRW/km{\times}day$ (115%) and $1,985,000KRW/km{\times}day$ (119%) occurred on Sections B and D with approximately 20,000 AADT respectively and the delay cost of $262,000KRW/km{\times}day$ (105%) occurred on Section C with approximately 10,000 AADT. This result of this study was estimated based on the simulation of traffic flow model so that there is a limitation in its actual application. A study ot develop a highly appropriate model using actual observation data and improve the possibility to apply it through the verification using the simulation will be necessary in future.

Verifying the Classification Accuracy for Korea's Standardized Classification System of Research F&E by using LDA(Linear Discriminant Analysis) (선형판별분석(LDA)기법을 적용한 국가연구시설장비 표준분류체계의 분류 정확도 검증)

  • Joung, Seokin;Sawng, Yeongwha;Jeong, Euhduck
    • Management & Information Systems Review
    • /
    • v.39 no.1
    • /
    • pp.35-57
    • /
    • 2020
  • Recently, research F&E(Facilities and Equipment) have become very important as tools and means to lead the development of science and technology. The government has been continuously expanding investment budgets for R&D and research F&E, and the need for efficient operation and systematic management of research F&E built up nationwide has increased. In December 2010, The government developed and completed a standardized classification system for national research F&E. However, accuracy and trust of information classification are suspected because information is collected by a method in which a user(researcher) directly selects and registers a classification code in NTIS. Therefore, in the study, we analyzed linearly using linear discriminant analysis(LDA) and analysis of variance(ANOVA), to measure the classification accuracy for the standardized classification system(8 major-classes, 54 sub-classes, 410 small-classes) of the national research facilities and equipment established in 2010, and revised in 2015. For the analysis, we collected and used the information data(50,271 cases) cumulatively registered in NTIS(National Science and Technology Service) for the past 10 years. This is the first case of scientifically verifying the standardized classification system of the national research facilities and equipment, which is based on information of similar classification systems and a few expert reviews in the in-outside of the country. As a result of this study, the discriminant accuracy of major-classes organized hierarchically by sub-classes and small-classes was 92.2 %, which was very high. However, in post hoc verification through analysis of variance, the discrimination power of two classes out of eight major-classes was rather low. It is expected that the standardized classification system of the national research facilities and equipment will be improved through this study.

Comparison of Nutrient Replenishing Effect under Different Mixing Methods in a Closed-loop Soilless Culture using Solar Radiation-based Irrigation (적산 일사 제어법으로 관수하는 순환식 수경재배에서 배액 혼합 방식에 의한 재사용 양액 내 양분 조정효과 비교)

  • Ahn, Tae-In;Shin, Jong-Hwa;Noh, Eun-Hee;Son, Jung-Eek
    • Journal of Bio-Environment Control
    • /
    • v.20 no.4
    • /
    • pp.247-252
    • /
    • 2011
  • Electrical conductivity, drainage, and irrigation amount of nutrient solution are important factors for determination of the mixing ratio of fresh and reused nutrient solutions in closed-loop soilless culture. Generally a fixed mixing ratio is applied in commercial scale greenhouses using solar radiation-based irrigation system. Although it ensures continuous supply of fresh nutrient solution in the mixing process, occasional discharge of the drainage is inevitably required. This study was conducted to compare the nutrient replenishing effect under different mixing processes and to investigate appropriate mixing process. For this experiment, a fixed mixing ratio (FR), modifiable mixing ratio (MR), and open-loop (OP) as control were applied. Mixing ratio was determined by a set value of EC for dilution of collected drainage in FR and the set values of 1.0 and $2.0dS{\cdot}m^{-1}$ were used as treatments (FR 1.0 and FR 2.0), respectively. In MR, mixing ratio was determined based on EC and volume of drainage within irrigation volume per event. The volume of drainage stored in the drainage tank tended to increase in FR 1.0. Although such trend was not observed in FR 2.0 and MR, the volume of drainage stored in MR was lower than that in FR 2.0. The ion balance of $Mg^{2+}:K^+:Ca^{2+}$ or $SO^{2-}_4:NO^-_3:PO^{3-}_4$ in the drainage and reused nutrient solution changed within a narrow range regardless of treatment.