• Title/Summary/Keyword: Current Source Direction

Search Result 100, Processing Time 0.021 seconds

Current Status and Prospects of Standard Methods for the Measurements of Air Pollution in Korea (대기오염공정시험법의 체계구축과 개선방향)

  • Kim, Ki-Hyun;Bae, Min-Suk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.4
    • /
    • pp.439-446
    • /
    • 2013
  • In this research, the present standard analytical methods for the monitoring of air pollution levels established by the Korean Ministry of Environment (KMOE) were examined in reference to the recent outputs of several research projects conducted for their amendments. The evaluation of the two criterion methods between the main (the present guideline) and reference methods (the proposed alternate guideline) was made in terms of authenticity and reliability of the quality assurance (QA) and of compatibility of methods. The results of this comparative evaluation are presented for the analysis of both ambient air and source samples. Based on this analysis, we propose a new direction for the future amendment.

Analysis and Improvement for Performance of the Muffler of a Tracter (트랙터 소음기의 성능해석 및 개선에 관한 연구)

  • 이규태;도중석;오재응
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.4
    • /
    • pp.151-159
    • /
    • 1998
  • The heavy equipment such as tracter has been studied to improve rather the performance of engine than comfort. The mufflers of tracters have various specifications according to their uses. The exact analysis of various mufflers is needed to reduce the level of exhaust moise, a major noise source of engine, to improve the ride quality of tracter. In this study, a software based on Green's function is developed to predict the performance of sound transmission loss for a muffler according to the locations of inlet/outlet pipes. The locations of inlet and outlet pipes can be fixed at different position individually. The conventional muffler has the locations of inlet/outlet pipes on the direction of longitudinal axes. On other hand, the inlet and outlet pipes may be located at the circumferential surface of a test muffler such as one of tracter. The software is verified by analysis and experiment on current muffler of tracter and the improvement technique is proposed to reduce the level of exhaust noise.

  • PDF

Study on Electrohydrodynamic Analysis of Cylinder Type ESP (원통형 전기집진기의 전기유체역학적 해석에 관한 연구)

  • 조용수;여석준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.243-254
    • /
    • 1996
  • The main purpose of this study is to investigate the collection efficiency characteristics of a cylindrical ESP. To do that, it is necessary to analyze the electric field, gas flow field, and mechanism of particle movement by numerical simulation based on EHD model. For a gas flow field, Navier-Stokes equation involving the electric source term was solved by SIMPLE algorithm. In case of the electric field, the current continuity and electric field equations were solved by S.O.R. method. The analysis of particle movement was performed on the basis of PSI-CELL model from the Lagrangian viewpoint. The results showed that the influence on the gas flow field by the electric field is almost negligible in a cylindrical ESP. The particle drift velocity $V_P$ toward the collection surface is increased continuously by the electrostatic force due to the rise of particle charge as the particle is moving to the flow direction and the particle size becomes larger. The collection efficiency is to quitely higher with the increase of applied voltage for the same particle size, while becomes smaller as the inlet velocity is increased.

  • PDF

Multi-Step Commutation and Control Policies for Matrix Converters

  • Hofmann, Wilfried;Ziegler, Marcus
    • Journal of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.24-32
    • /
    • 2003
  • The commutation and control in matrix converters is more complicated as in voltage source converters. Natural freewheeling paths do not exist and the theoretic absent storage elements result in a direct coupled system of load and line currents as well as voltages. The paper offers an overview about staggered commutation and control policies in matrix converters. Based on the knowledge about load current direction and the signs of the line to line input voltages different multi-step commutation policies were derived. This paper examines the application of that policies in the case of space vector modulation and direct control methods with the focus on the resulting effects to the reference output voltage deviation.

STaRS Gen 2: Sejong Radiative Transfer through Raman and Rayleigh Scattering in Dusty Medium

  • Chang, Seok-Jun;Lee, Hee-Won;Seon, Kwang-Il
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.81.2-81.2
    • /
    • 2021
  • Emission features formed through Raman scattering with atomic hydrogen provide unique and crucial information to probe the distribution and kinematics of a thick neutral region illuminated by a strong far-ultraviolet radiation source. We introduce a new 3-dimensional Monte-Carlo code to describe the radiative transfer of line photons subject to Raman and Rayleigh scattering with atomic hydrogen. In our Sejong Radiative Transfer through Raman and Rayleigh Scattering (STaRS) code, the position, direction, wavelength, and polarization of each photon is traced until escape. The thick neutral scattering region is divided into multiple cells. Each cell is characterized by its velocity and density, which ensures flexibility of the code in analyzing Raman-scattered features formed in a neutral region with complicated kinematics and density distribution. We are continuously developing STaRS to adopt the absorption and scattering effect by dust. This presentation introduces STaRS and its current state and study.

  • PDF

Derivation of the Transient. Solution of the Horizontal Interfacial Electric Field Generated by a Tiny Horizontal Current Source on a Uniaxially Anisotropic Half-Space Dielectric (단축 이방성 반공간 유전체 표면에서 수평 미세 전류원에 의해 발생하는 수평 경계면 전기장에 대한 시영역 해의 유도)

  • 이원석;남상욱
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.2
    • /
    • pp.313-321
    • /
    • 2000
  • This paper deals with a kind of the half-space interfacial problem in time domain, requiring the calculation of the horizontal electric field generated by a tiny impulsive current source located horizontally at the interface between an isotropic upper half-space and a uniaxially anisotropic lower half-space. With the Cagniard-de-Hoop method adapted for our interfacial case, we obtain the explicit-form solution for this electric field. We also investigate the impulse radiation in the radial direction. The impulse components of Dirac $\delta$-function type in transient waveforms are important for the understanding of the interfacial far-field characteristics. The uniaxial case is a generalization of the isotropic one, and the explicit solutions of the uniaxial problem in this paper reduce to the solutions of the isotropic problem if the anisotropy is removed.

  • PDF

pH Sensitive Graphene Field-Effect Transistor(FET) (pH에 민감한 그래핀 전계효과 트랜지스터(FET))

  • Park, Woo Hwan;Song, Kwang Soup
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.2
    • /
    • pp.117-122
    • /
    • 2016
  • Recently, the detection of pH with real-time and in vivo has been focal pointed in the environmental or medical fields. In this work, we developed the pH sensor using graphene sheet. Graphene has high biocompatibility. We fabricated flexible solution-gated field-effect transistors (SGFETs) on graphene sheet transferred on the polyethylene terephthalate (PET) substrate to detect pH in electrolyte solution. The gate length was $500{\mu}m$ and the gate width was 8 mm. We evaluated the current-voltage (I-V) transfer characteristics of graphene SGFETs in pH solution. The drain-source current ($I_{DS}$) and the gate-source voltage ($V_{GS}$) curves of graphene SGFETs were depended on pH value. The Dirac point of graphene SGFETs linearly shifted to the positive direction about 19.32 mV/pH depending on the pH value in electrolyte solution.

A Study on the Improvement for Industrial Land Information System (산업입지정보시스템 개선에 관한 연구)

  • Lim, Jae-Deok;Kim, Seong-Geon;Shin, Chul-Young
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.1
    • /
    • pp.35-43
    • /
    • 2019
  • This paper is a study on the improvement of industrial land information system. Status and problems of current industrial land information system is analyzed to establish objectives and methods and direction of improving the system based on our analysis. Since the industrial land information system is using outdated H/W and commercial S/W, there exists problems such as large maintenance cost, difficulty of immediate response for system problems and limited access of searching and providing information. In this paper, the problems of current system is resolved through applying the "e-Government standard framework" and open source S/W. And we suggested application of functions on information link enhancement and visualization through this research. Our research is expected to be applicable for analyzing/designing and developing system improvement in the future.

A Study on the Current Status of Building Envelope in detached houses of near Local Cities - with Staff of Small-sized Architectural Design Firms in Gwangju and Jeonnam - (지방도시근교 단독주택의 외피구성 현황에 관한 연구 - 광주광역시/전남 소규모 건축설계사무소 실무자를 대상으로 -)

  • Park, Sung-Jin;Lee, Chang-Jae
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.53-60
    • /
    • 2013
  • This study examined the building envelope structure used in small housings near urban area which have not good energy source in relation to the application of passive design for energy saving of small-sized architectural design firms in local cities and aimed to provide the basic materials of future design direction of designers and housing owners by analyzing economy of a project in order to know the amount of energy saving and additional expenses depending on the building envelope pattern. As a result of comparing and examining the energy saving cost from the period of use compared to investment by the thickness of insulating materials based on building envelope pattern for energy saving, it was found that the thicker the insulating materials are, the more energy saving amount is. While the current bead-type insulating materials have short payback period due to low initial investment, extruded insulating materials show the difference of five years compared to bead-type insulation because of its high initial investment.

Development of the Spark-gap Switch with Dual Trigger System (쌍방향 시동방식의 고속투입스위치 개발)

  • Kim, Maeng-Hyeon;Seo, Yun-Taek;Park, Seung-Jae;Park, Byeong-Rak;Go, Ui-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.7
    • /
    • pp.359-364
    • /
    • 2000
  • This paper is introducing a newly developed spark-gap switch with dual trigger system, into which the current from the voltage source is injected along with the test sequence during the synthetic testing of high voltage circuit-breaker. The currently-used spark gap switch is narrow in operating range due to the use of the method of triggering energy being injected by single way. As a result, the frequent happening of misoperation has greatly reduced the test quality and test efficiency and has required the cost of maintenance excessively. In this study, accordingly, in order to basically remove these problems, another triggering system is installed to the opposite direction on the existing triggering system; attaching the same time and the same rising time of pulse wave as on the existing system, so that at a comparatively trigger gap distance from the main electrode(the gap can be operated at 60% of self-break voltage, while at 80% in the current system), the main electrode has been enabled to be closed by the development of spark gap switch with dual trigger system.

  • PDF