Abstract
Recently, the detection of pH with real-time and in vivo has been focal pointed in the environmental or medical fields. In this work, we developed the pH sensor using graphene sheet. Graphene has high biocompatibility. We fabricated flexible solution-gated field-effect transistors (SGFETs) on graphene sheet transferred on the polyethylene terephthalate (PET) substrate to detect pH in electrolyte solution. The gate length was $500{\mu}m$ and the gate width was 8 mm. We evaluated the current-voltage (I-V) transfer characteristics of graphene SGFETs in pH solution. The drain-source current ($I_{DS}$) and the gate-source voltage ($V_{GS}$) curves of graphene SGFETs were depended on pH value. The Dirac point of graphene SGFETs linearly shifted to the positive direction about 19.32 mV/pH depending on the pH value in electrolyte solution.
최근 환경, 의료분야에서 실시가 검출 및 인체 삽입형 pH 센서에 대한 요구가 증가하고 있다. 이에 본 연구에서는 생체적 합성이 우수한 그래핀을 이용하여 실시간 pH 검출이 가능한 센서를 개발하였다. Polyethylene terephthalate(PET) 기판에 전사된 그래핀 표면에 이온 용액속에서 동작하는 전계효과 트랜지스터(solution-gated field-effect transistors; SGFETs)를 제작하였으며 이를 이용하여 이온 용액의 pH를 검출하였다. 제작한 트랜지스터의 게이트 채널 길이는 $500{\mu}m$, 게이트 채널 폭은 8mm이다. 이온 용액속에서 트랜지스터 동작특성 및 pH 감도를 평가하기 위하여 드레인-소스 전압($V_{DS}$)에 따른 드레인-소스 전류($I_{DS}$) 및 게이트-소스 전압($V_{GS}$)에 따른 드레인-소스 전류($I_{DS}$)를 측정하였다. PET기판에 전사된 그래핀 위에 제작한 그래핀 SGFETs의 전류-전압 특성은 이온 용액내에서 매우 안정적으로 동작하였으며 그래핀 SGFETs의 Dirac point는 이온 용액의 pH값이 증가함에 따라 양의 방향으로 19.32 mV/pH씩 증가하였다.