• Title/Summary/Keyword: Clean

Search Result 5,310, Processing Time 0.029 seconds

Unconfined Compressive Strength of Fiber-reinforced Cemented Sands by Fiber Reinforcement Form (섬유의 보강 형태에 따른 섬유-시멘트 혼합토의 일축압축강도특성)

  • Park, Sung-Sik;Kim, Young-Su;Lee, Jong-Cheon
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.8
    • /
    • pp.159-169
    • /
    • 2007
  • The behavior of fiber-reinforced cemented sands (FRCS) was studied to improve a brittle failure mode observed in cemented sands. Nak-dong River sand was mixed with ordinary Portland cement and a Polyvinyl alcohol (PVA) fiber. A PVA fiber is widely used in concrete and cement reinforcement. It has a good adhesive property to cement and a specific gravity of 1.3. A PVA fiber has a diameter of 0.1 mm that is thicker than general PVA fiber for reinforced cement. Clean Nak-dong River sand, cement and fiber at optimum water content were compacted in 5 layers giving 55 blows per layer. They were cured for 7 days. Cemented sands with a cement/sand ratio of 4% were fiber-reinforced at different locations and tested for unconfined compression tests. The effect of fiber reinforcement form and distribution on strength was investigated. A specimen with evenly distributed fiber showed two times more strength than not-evenly reinforced specimen. The strength of fiber-reinforced cemented sands increases as fiber reinforcement ratio increases. A fully reinforced specimen was 1.5 times stronger than a specimen reinforced at only middle part. FRCS behavior was controlled not only by a dosage of fiber but also by fiber distribution methods or fiber types.

Bacterial Contamination in Disposable Wet Wipes in General Restaurants 2nd (대중음식점 일회용 물티슈의 세균 오염도 조사(2))

  • Chong, Moo-Sang
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.54 no.1
    • /
    • pp.23-27
    • /
    • 2022
  • Disposable wet wipes provided by general restaurants in the Jeju Special Self-Governing Province were evaluated for compliance with the labeling requirements and the degree of bacterial contamination set by the Ministry of Food and Drug Safety. Of the 32 types of disposable wipes, five types of disposable wipes did not indicate the name and location of the business office of the manufacturer. Only 12 types of wet wipes were marked with the date of manufacture and expiration date. Bacterial contamination was seen in 9 types of wet wipes through bacterial culture but these were absent in the remaining 23 types (71.9%). The results of the antimicrobial susceptibility test for the 9 identified strains showed no methicillin-resistant coagulase-negative staphylococci (MRCNS) or multidrug-resistant bacteria. Through this study, it is recommended that the date of manufacture and expiration date must be indicated on the surface of disposable wet wipes designated as hygiene products, and clean uncontaminated wet wipes must comply with storage standards. In addition, the results are expected to contribute to the enhancement and improvement of hygiene management supervision, personal hygiene management, and an improvement in national health.

Smoke Control Experiment of a Very Deep Underground Station Where Platform Screen Doors are Installed (I) - Analysis on Smoke Control Performance on the Platform (스크린도어가 설치된 대심도 지하역사의 제연 실험 I - 승강장에서의 제연의 효과 분석)

  • Park, Won-Hee;Kim, Chang-Yong;Cho, Youngmin;Kwon, Tae-Soon;Lee, Duck-Hee
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.7
    • /
    • pp.485-496
    • /
    • 2018
  • In this paper, the smoke behavior in an underground station on operation of the fans in the ventiliation of the station was measured by the experimental method when the fire occurred in the underground station platform where the platfrom screen door was installed. The ventilation characteristics were compared when the ventilation system was operated and when the ventilation system was not operated when a fire occurred at the platform where the clean door was closed. To simulate the fire smoke, the smoke generated from the smoke generator was heated using a hot air fan. The transmittance was measured using a smoke density meter to quantitatively measure fire smoke. If the screen door is closed and the ventilation system of the underground station does not work, it is confirmed that if a fire occurs in the platform, smoke accumulates inside the platform, evacuating passengers is very difficult and can lead to a very dangerous situation. On the other hand, under the condition that the ventilation facility of the subway station is operated, the smoke evacuates to the outside through the ventilation facility of the underground station, and airflow is formed in the direction from the waiting room to the waiting area, so that the passenger located on the platform can safely evacuate toward the concourse. In the following paper, we will discuss the concurrent effect of tunnel ventilation through tunnel vent near the platform.

A Study on the Effect among the Service Quality of Coffee Shop, Store Attitude and Store Loyalty: Focusing on the Construal Level (커피전문점 서비스품질, 점포태도, 점포충성도의 영향관계 연구 : 개인 해석수준의 영향을 중심으로)

  • Kang, Hwa-Seok
    • The Korean Journal of Franchise Management
    • /
    • v.9 no.2
    • /
    • pp.39-52
    • /
    • 2018
  • Purpose - This study investigates the effect of service quality of coffee shop on store attitude and store loyalty. It demonstrates that the individual's behavior identification level plays a moderating role when the service quality of coffee shop affects store attitude. Conceptually drawing on Brady & Cronin's three-dimensional model of service quality, this study examines the effect of service quality of coffee specialty store on customer's attitudes and loyalty. Also, according to construal level theory, it examines the individual's propensity difference whether the individual's behavior identification level on service quality and store attitude has a moderating effect Research design, data, and methodology - This study used Brady & Cronin's three-dimensional service quality model, and 183 valid cases collected through the questionnaire survey were used for data analyses. For hypothesis testing, regression analysis, multiple regression analysis, and covariance analysis were conducted. Result- As a result of this study, first, it is confirmed that service quality has a positive effect on store attitude toward coffee shop. Second, the difference of an individual's construal level did not have a moderating effect on the influential relationship of service quality on the store attitude of coffee shop. This is because the influence of the service quality is greater than the difference between groups at the construal level. Therefore, there was no moderating influence according to construal level. Third, the store attitude of coffee specialty store has a positive effect on store loyalty. Conclusions - It is confirmed that there is a difference in the effect of service quality and store attitude on general and college students. This suggests that it can be used to establish marketing strategies by segment. And, the college students were found to be more influenced by physical environment quality factor among three dimensions of service quality. Therefore, it is necessary to further improve efforts to raise the level of service quality perception through physical environmental factors such as clean and pleasant environment including the interior of a coffee shop, and internal table arrangement. The empirical study on the moderating effects of customer's tendency of difference is meaningful in the absence of empirical studies.

Efficient Poisoning Attack Defense Techniques Based on Data Augmentation (데이터 증강 기반의 효율적인 포이즈닝 공격 방어 기법)

  • So-Eun Jeon;Ji-Won Ock;Min-Jeong Kim;Sa-Ra Hong;Sae-Rom Park;Il-Gu Lee
    • Convergence Security Journal
    • /
    • v.22 no.3
    • /
    • pp.25-32
    • /
    • 2022
  • Recently, the image processing industry has been activated as deep learning-based technology is introduced in the image recognition and detection field. With the development of deep learning technology, learning model vulnerabilities for adversarial attacks continue to be reported. However, studies on countermeasures against poisoning attacks that inject malicious data during learning are insufficient. The conventional countermeasure against poisoning attacks has a limitation in that it is necessary to perform a separate detection and removal operation by examining the training data each time. Therefore, in this paper, we propose a technique for reducing the attack success rate by applying modifications to the training data and inference data without a separate detection and removal process for the poison data. The One-shot kill poison attack, a clean label poison attack proposed in previous studies, was used as an attack model. The attack performance was confirmed by dividing it into a general attacker and an intelligent attacker according to the attacker's attack strategy. According to the experimental results, when the proposed defense mechanism is applied, the attack success rate can be reduced by up to 65% compared to the conventional method.

Investigation of Applying Technical Measures for Improving Energy Efficiency Design Index (EEDI) for KCS and KVLCC2

  • Jun-Yup Park;Jong-Yeon Jung;Yu-Taek Seo
    • Journal of Ocean Engineering and Technology
    • /
    • v.37 no.2
    • /
    • pp.58-67
    • /
    • 2023
  • While extensive research is being conducted to reduce greenhouse gases in industrial fields, the International Maritime Organization (IMO) has implemented regulations to actively reduce CO2 emissions from ships, such as energy efficiency design index (EEDI), energy efficiency existing ship index (EEXI), energy efficiency operational indicator (EEOI), and carbon intensity indicator (CII). These regulations play an important role for the design and operation of ships. However, the calculation of the index and indicator might be complex depending on the types and size of the ship. Here, to calculate the EEDI of two target vessels, first, the ships were set as Deadweight (DWT) 50K container and 300K very large crude-oil carrier (VLCC) considering the type and size of those ships along with the engine types and power. Equations and parameters from the marine pollution treaty (MARPOL) Annex VI, IMO marine environment protection committee (MEPC) resolution were used to estimate the EEDI and their changes. Technical measures were subsequently applied to satisfy the IMO regulations, such as reducing speed, energy saving devices (ESD), and onboard CO2 capture system. Process simulation model using Aspen Plus v10 was developed for the onboard CO2 capture system. The obtained results suggested that the fuel change from Marine diesel oil (MDO) to liquefied natural gas (LNG) was the most effective way to reduce EEDI, considering the limited supply of the alternative clean fuels. Decreasing ship speed was the next effective option to meet the regulation until Phase 4. In case of container, the attained EEDI while converting fuel from Diesel oil (DO) to LNG was reduced by 27.35%. With speed reduction, the EEDI was improved by 21.76% of the EEDI based on DO. Pertaining to VLCC, 27.31% and 22.10% improvements were observed, which were comparable to those for the container. However, for both vessels, additional measure is required to meet Phase 5, demanding the reduction of 70%. Therefore, onboard CO2 capture system was designed for both KCS (Korea Research Institute of Ships & Ocean Engineering (KRISO) container ship) and KVLCC2 (KRISO VLCC) to meet the Phase 5 standard in the process simulation. The absorber column was designed with a diameter of 1.2-3.5 m and height of 11.3 m. The stripper column was 0.6-1.5 m in diameter and 8.8-9.6 m in height. The obtained results suggested that a combination of ESD, speed reduction, and fuel change was effective for reducing the EEDI; and onboard CO2 capture system may be required for Phase 5.

Determining of polycyclic aromatic hydrocarbons in domestic vegetables and fruits (국내유통 채소류 및 과일류 중 다환방향족탄화수소 분석)

  • Hu, Soojung;Oh, Nam Su;Kim, Soo Yeon;Lee, Hyomin
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.415-421
    • /
    • 2006
  • The following concentrations of some PAHs were investigated; [benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, benzo(g,h,i)perylene, indeno (1,2,3-c,d)pyrene] in vegetables(n=160) and fruits(n=50). The food samples were purchased at the local markets in Seoul, Chuncheon, Daejeon, Kwangju and Pusan. The samples were radish, onion, bean sprouts, welsh onion, chinese cabbage, spinach, young pumpkin, garlic, cucumber, carrot, lettuce, sesame leaf, tangerine, persimmon, apple, pear and banana. The methodology involved ultrasonic extraction with dichloromethane, clean-up on Sep-Pak florisil cartridges and determination by HPLC/FLD (High Performance Liquid Chromatography/Fluorescence Detector). Overall method recoveries for 8 PAHs spiked into these products ranged from 95 to 102%. The mean level of the following PAHs were determined; benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, benzo(g,h,i)perylene and indeno(1,2,3-c,d)pyrene in vegetables and fruits was N.D., 0.014 ng/g, 0.031 ng/g, 0.016 ng/g, 0.019 ng/g, 0.091 ng/g, 0.016 ng/g and N.D., respectively.

Determination of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCCOOH) in human urine by solid-phase extraction and GC/MS (고체상 추출과 GC/MS를 이용한 소변 중 대마 대사체 (THCCOOH) 분석)

  • Cheong, Jae Chul;Kim, Jin Young;In, Moon Kyo;Cheong, Won Jo
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.441-448
    • /
    • 2006
  • 11-nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol (THCCOOH) is the major metabolite of tetrahydrocannabinol (THC) which is the primary psychoactive component of marijuana. It is also the target analyte for the discrimination marijuana use. A method using solid-phase extraction (SPE) and gas chromatography/mass spectrometry (GC/MS) was developed for the determination of THCCOOH in human urine. Urine samples (3 mL) were extracted by SPE column with a cation exchange cartridge after basic hydrolysis. The eluents were then evaporated, derivatized, and injected into the GC/MS. The limits of detection (LOD) and quantitation (LOQ) were 0.4 and 1.2 ng/mL, respectively. The response was linear with a correlation coefficient of 0.999 within the concentration range of 1.2 (LLE 1.3)~50.0 ng/mL. The precision and accuracy were stable within 1.20% and the recovery was 83.6~90.7%. The recovery of SPE method was lower than that of liquid-liquid extraction (LLE), but there were no apparent differences in LOD, LOQ, precision and accuracy between the two methods. While SPE method is used as a very effective and rapid procedure for sample pretreatment, and clean extracts, LLE method was not suitable for the extraction procedure of THCCOOH in urine. The applicability of the method was proven by analyzing a urine samples from a marijuana abusers.

Analysis of polycyclic aromatic hydrocarbons in cooked fish and shellfish (조리어패류 중 다환방향족탄화수소 분석)

  • Hu, Soojung;Park, Sungkuk;Jin, Sunhee;Choi, Dongmi
    • Analytical Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.109-117
    • /
    • 2009
  • The following concentrations of some PAHs were investigated; [benzo(a)anthracene, chrysene, benzo (b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, benzo(g, h, i)perylene, indeno (1,2,3-c,d)pyrene] in fish(n=168) and shellfish(n=40). The methodology involved saponification and extraction with n-hexane, clean-up on Sep-Pak Florisil Cartridges and determination by HPLC/FLD (High Performance Liquid Chromatograph/Fluorescence Detector). Overall method recoveries for 8 PAHs spiked into these products ranged from 88 to 112%. The mean level of benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(k) fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, benzo(g,h,i)perylene and indeno(1,2,3-c,d)pyrene in cooked fish was ND, ND, 0.0009, ND, 0.01, ND, ND, ND and in cooked shellfish was 1.84, 3.51, 0.81, 0.38, 0.39, 0.04, 0.20, ND, respectively.

Determination of acidic pharmaceuticals in aquatic environmental samples by LC/ESI-MS/MS (LC/ESI-MS/MS를 이용한 수질 환경 시료 중 산성의약물질 분석방법 비교)

  • Sim, Young-Eun;Cho, Hyun-Woo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.191-200
    • /
    • 2008
  • Pharmaceuticals and personal care products (PPCPs) are emerging contaminants in aquatic environmental samples. Therefore, it required rapidly and certainly analytical method for pharmaceuticals which are existed in environment. In this study, Liquid chromatography/tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI) was used to measure the concentrations of 7 pharmaceuticals (quinoxaline-2-carboxylic acid, acetylsalicylic acid, diclofenac-Na, naproxen, ibuprofen, mefenamic acid, talniflumate) from environmental water or aquatic samples simultaneously. Effective sample clean-up by solid-phase extraction (SPE) prior to LC-MS/MS analysis is necessary. For further purification, Mixed Cation eXchange (MCX) and Hydrophilic-Lipophilic Balance (HLB) solid-phase extraction (SPE) cartridges were used to eliminate the remaining interferences. LODs (Limits of Detection) and MDLs (Method Detection Limits) for the spiked sample in fresh water were in the range of 0.05~1.50 pg/mL and 0.17~4.90 pg/mL, respectively. The absolute recovery in the concentration of 1.0 ng/mL were between 81.9 and 116.3%. The acidic pharmaceuticals were detected in concentrations of 0.018~16.925 ng/mL in aquatic environmental samples.