• Title/Summary/Keyword: Carrier Polarity

Search Result 19, Processing Time 0.023 seconds

Performance of 2-Carrier DS system and its MODEM designed for Power Line Transmission (전력선 통신을 위한 2-반송파 DS방식의 특성과 MODEM의 구현)

  • 김인태;이무영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.3
    • /
    • pp.582-590
    • /
    • 1994
  • This paper introduce a highly verstile and simple data transmission system designed for commercial power distribution lines. The system operates on the DSSS principle but utilizes two independent carrier frequencies each represents polarity of DS MODEM outiputs. At the receiving terminal, outputs of two envelope detectors are directly applied to separate DS correlators before the two components are compared. The recovered signals which represents data and line noise are then compared at comparator. With the noise power greatly rudused at the correlator, the error rate of the data observed at comparator desplays great improvement comparing to the conventional FSK-DS system in which the detector output are compared before the correlator stage. Despite its simplest structure, the prototype MODEM transmitts 2400 bps with the error rate 10 , about 10dB improved compared to conventional FSK system.

  • PDF

Organic Bistable Switching Memory Devices with MeH-PPV and Graphene Oxide Composite

  • Senthilkumar, V.;Kim, Yong Soo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.5
    • /
    • pp.290-292
    • /
    • 2015
  • We have reported about bipolar resistive switching effect on Poly[2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene]:Graphene oxide composite films, which are sandwiched between aluminum and indium tin oxide electrodes. In this case, I-V sweep curve showed a hysteretic behavior, which varied according to the polarity of the applied voltage bias. The device exhibited excellent switching characteristics, with the ON/OFF ratio being approximately two orders in magnitude. The device had good endurance (105 cycles without degradation) and long retention time (5 × 103 s) at room temperature. The bistable switching behavior varied according to the trapping and de-trapping of charges on GO sites; the carrier transport was described using the space-charge-limited current (SCLC) model.

Reliability of Low Temperature Poly-Si TFT employing Counter-doped Lateral Body Terminal (저온 다결정 실리콘 박막 트랜지스터의 신뢰도 향상을 위한 Counter-doped Lateral Body Terminal (CLBT) 구조)

  • Kim, J.S.;Yoo, J.S.;Kim, C.H.;Lee, M.C.;Han, M.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1442-1444
    • /
    • 2001
  • A new low-temperature poly-Si TFT employing a counter-doped lateral body terminal is proposed and fabricated, in order to enhance the stability of poly-Si TFT driving circuits. The LBT structure effectively suppresses the kink effect by collecting the counter-polarity carriers and suppresses the hot carrier effect by reducing the peak lateral field at the drain junction. The proposed device is immune to dynamic stress, so that it is suitable for low voltage and high speed driving circuits of AMLCD.

  • PDF

Control of Three-Phase Three-Switch Buck-Type Rectifier in EV Rapid Charging Systems

  • Chae, Beomseok;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.189-190
    • /
    • 2015
  • This paper investigates an economic and highly efficient power converter topology and its modulation scheme for 60kW rapid EV charger system. The target system consists of three-phase three-switch buck-type rectifier topology. A new Carrier Based PWM scheme along with its simple implementation using logic gates is introduced in this paper. This PWM scheme replaces the diode rectifier equivalent switching state with an active switching state producing the effectively same current flowing path. As a result, the distortion of input current during the polarity reversal of capacitor line voltage can be mitigated. The proposed modulation technique is confirmed through simulation verification. The proposed modulation technique and its implementation scheme can expand the operation range of the three-phase three-switch buck-type rectifier having ac input and capacitor ripple current of high quality.

  • PDF

Design of Carrier Recovery Circuit for High-Order QAM - Part II : Performance Analysis and Design of the Gear-shift PLL with ATC(Automatic Transfer-mode Controller) and Average-mode-change Circuit (High-Order QAM에 적합한 반송파 동기회로 설계 - II부. 자동모드전환시점 검출기 및 평균모드전환회로를 적용한 Gear-Shift PLL 설계 및 성능평가)

  • Kim, Ki-Yun;Kim, Sin-Jae;Choi, Hyung-Jin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.38 no.4
    • /
    • pp.18-26
    • /
    • 2001
  • In this paper, we propose an ATC(Automatic Transfer mode Controller) algorithm and an average-mode-change method for use in Gear shift PLL which can automatically change loop gain. The proposed ATC algorithm accurately detects proper timing or the mode change and has a very simpler structure - than the conventional lock detector algorithm often used in QPSK. And the proposed average mode change method can obtain low errors of estimated frequency offset by averaging the loop filter output of frequency component in shift register. These algorithms are also useful in designing ASIC, since these algorithms occupy small circuit area and are adaptable for high speed digital processing. We also present phase tracking performance of proposed Gear-shift PLL, which is composed of polarity decision PD, ATC and average mode change circuit, and analyze the results by examining constellation at each mode.

  • PDF

Drug-release Properties of Double-layered Microspherical Carriers which Consist of Outer Shell of Poly(D,L-lactide) and Inner Core of Alginate or Chitosan (Poly(D,L-lactide)를 외부 껍질로 하고 Alginate 또는 Chitosan을 내부 코어로 구성한 이중미립구 담체의 약물방출 특성)

  • Kim, Ja Won;Song, Min Jeong;Lee, Sang Min;Lim, So Ryong;Jung, Su Jin;Kim, Hong Sung
    • Polymer(Korea)
    • /
    • v.36 no.6
    • /
    • pp.699-704
    • /
    • 2012
  • Double-layered polymeric carrier was designed for release control of hydrophilic drug in oral administration. Biopolymeric chitosan and alginate were examined as polar absorbents, poly(D,L-lactide) as a hydrophobic shell, and theophylline and diclofenac sodium as loading drugs. The fabrication of the carriers was prepared in the form of double-layered microsphere for delayed and successively extended release, which consisted of outer shell of poly(D,L-lactide) and inner core of alginate or chitosan with drugs. Morphologies and drug-release behaviors of the carriers were investigated, which were influenced by a combination of polarity between carrier and drug. It was confirmed that the relative polarities of the carriers, the drugs, and the environmental pH affected significantly the drug-release property.

A Frequency Offset Compensation Technique for the High Order QAM using a Phase Differential Equation (고차 QAM에 적합한 위상 미분을 이용한 주파수 오차 보정 회로)

  • 박상열;윤태일;조경록
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.10
    • /
    • pp.27-33
    • /
    • 2004
  • In this paper, we present a carrier recovery circuit using the polarity-decision algorithm that recovers a phase and a frequency error simultaneously. The proposed algorithm catches a frequency error based on a differential of an angular velocity of the signal constellations. Using the differential of a phase error may compensate the frequency error. The symbol prediction method in the proposed algorithm accumulates the symbols, which makes easy to calculate a phase differential. The hardware size of the algerian is small since we use Q data or I only to get phase information. As a result, the algerian shows a pull-in range of normalized frequency error 0.5 under AWGN 15dB.

Study for Facilitated Olefin Transport Phenomena Using Silver Oxide (Silver Oxide를 이용한 올레핀 촉진수송 현상 연구)

  • Ji, Dahye;Kang, Sang Wook
    • Membrane Journal
    • /
    • v.25 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • It was known that the polarlized surface of silver nanoparticles could be interacted revesibly with olefin molecules for facilitated olefin transport. However, it was thought that it can be regenerated by interaction between oxide surface of AgNPs and olefin molecules because the surface of the silver nanoparticles is easily oxidized in the air. In order to investigate the effect of the silver oxide, 5 wt% AgO or $Ag_2O$ was dispersed in polymer PVP solutions and 0.005~0.02% electron acceptor as TCNQ or p-BQ were added to fabricate the separation membrane. After the addition of the electron acceptor, it was expected to improve the polarity on the surface of the silver oxide and the degree of dispersion. The characteristics of the separation membrane were identified by the gas permeance, XPS and TEM.

Establishment of Analytical Method for Dichlorprop Residues, a Plant Growth Regulator in Agricultural Commodities Using GC/ECD (GC/ECD를 이용한 농산물 중 생장조정제 dichlorprop 잔류 분석법 확립)

  • Lee, Sang-Mok;Kim, Jae-Young;Kim, Tae-Hoon;Lee, Han-Jin;Chang, Moon-Ik;Kim, Hee-Jeong;Cho, Yoon-Jae;Choi, Si-Won;Kim, Myung-Ae;Kim, MeeKyung;Rhee, Gyu-Seek;Lee, Sang-Jae
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.3
    • /
    • pp.214-223
    • /
    • 2013
  • BACKGROUND: This study focused on the development of an analytical method about dichlorprop (DCPP; 2-(2,4-dichlorophenoxy)propionic acid) which is a plant growth regulator, a synthetic auxin for agricultural commodities. DCPP prevents falling of fruits during their growth periods. However, the overdose of DCPP caused the unwanted maturing time and reduce the safe storage period. If we take fruits with exceeding maximum residue limits, it could be harmful. Therefore, this study presented the analytical method of DCPP in agricultural commodities for the nation-wide pesticide residues monitoring program of the Ministry of Food and Drug Safety. METHODS AND RESULTS: We adopted the analytical method for DCPP in agricultural commodities by gas chromatograph in cooperated with Electron Capture Detector(ECD). Sample extraction and purification by ion-associated partition method were applied, then quantitation was done by GC/ECD with DB-17, a moderate polarity column under the temperature-rising condition with nitrogen as a carrier gas and split-less mode. Standard calibration curve presented linearity with the correlation coefficient ($r^2$) > 0.9998, analysed from 0.1 to 2.0 mg/L concentration. Limit of quantitation in agricultural commodities represents 0.05 mg/kg, and average recoveries ranged from 78.8 to 102.2%. The repeatability of measurements expressed as coefficient of variation (CV %) was less than 9.5% in 0.05, 0.10, and 0.50 mg/kg. CONCLUSION(S): Our newly improved analytical method for DCPP residues in agricultural commodities was applicable to the nation-wide pesticide residues monitoring program with the acceptable level of sensitivity, repeatability and reproducibility.