• Title/Summary/Keyword: Bus terminal

Search Result 105, Processing Time 0.022 seconds

A Experimental Study for Characteristic of Element Sound to Bus Terminal (버스터미널 현황음 특성에 관한 실험적 연구)

  • Song, Hyuk;Park, Hyeon-Ku;Song, Min-Jeoung;Jang, Gil-Soo;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.3 no.4
    • /
    • pp.33-36
    • /
    • 2003
  • Bus station is a public space which many people use and various activities are occurred in urban life. Main activities are waiting for departure or passengers with the feelings of joys and sorrows. Also sound information including announcing message of arrival and departure are to be considered carefully. Considering these roles of bus station, creating acoustic amenity is a prerequisite to the spaces. In this study, the spaces of bus station were classified into 4 spaces such as approaching path, waiting palace, departure and arrival platform. Observation survey was conducted to extract various activities in the view point of sound in each space. And subjective response was analyzed before and after introducing prepared sounds.

A Study on the Smoke Compartment Standards Analysis of Domestic and Abroad for Prevention of Smoke Spread in Large-Scale Buildings -Focused on the Analysis of Goyang Bus Terminal Fire Incident- (대형공간의 연기확산 방지를 위한 국내·외 방연구획 기준 분석에 관한 연구 -고양시 터미널 화재 사례 분석을 중심으로-)

  • Kim, Hye-Won;Han, Ji-Woo;Lee, Byeong-Heun;Jin, Seung-Hyeon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.118-119
    • /
    • 2018
  • In this study, it analyses the problems of the Fire Compartment in Goyang Bus Terminal. Based on analysed data, it is confirmed the necessity of the Smoke Compartment installation for Protecting the Smoke Spread in Large-Scale Buildings using of FDS(Fire Dynamics Simulation). In addition it suggest that the necessity of Smoke Compartment application method and Development of Design Guideline.

  • PDF

Implementation of IS-95C Multimedia Terminal using GPS (GPS 연동 IS-95C 멀티미디어 단말기 구현)

  • 하재승
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.8
    • /
    • pp.1133-1138
    • /
    • 2001
  • In this paper, we implemented that MMT(Multimedia Terminal) demonstrates spot news, weather forecast, sports news and cultural news employed CDMA mobile communication networks. The MMT displays mobile pictures/joint pictures/on screen ad and to make known Bus stop or Mobile stations. The MMT gives driver's and passenger's safety and valuable information for one's use GPS satellites. We verified to make real time mobile picture transfer use of CDMA2000 1×(IS-95C) network and development the scheduler control each module. This system tested on vehicle that train and bus. MMT was implemented high reliability and stability by the embedded system. The mobile terminal shows reliable data transfer rate about 74Kbps on IS-95C.

  • PDF

Implementation of a B-Link Interface Logic for a SCI Interconnect (SCI 연결망의 B-Link 인터페이스 회로 구현)

  • 한종석;모상만;기안도;한우종
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.412-415
    • /
    • 1999
  • In this paper, we describe an implementation of the B-Link bus interface logic for a directory controller and a remote access cash controller in the SCI-based CC-NUMA multimedia server developed by ETRI . The CC-NUMA multimedia server is composed of a number of Pentium III SHV nodes and a SCI interconnection network. To communicate with remote nodes, each node has a CC-Agent which consists of a processor bus interface(PIF). a directory controller(DC), a remote access cash controller(RC), and two SCI 1ink controllers(LCs). The B-Link bus interface logic is developed for a directory controller and a remote access cash controller in order to communicate with a SCI link controller on a B-Link bus. It consists of a sending master controller a receiving slave controller, and asynchronous data buffers. And It performs a self-arbitration, a data packet transmission, a queue allocation, an early terminal ion. and a cut-through data path.

  • PDF

Analysis of the Working Conditions of Screen Fire Shutters in the Goyang Bus Terminal Fire (고양종합터미널화재 시 스크린방화셔터의 작동실태 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.82-91
    • /
    • 2018
  • This study analyzed the working conditions and problems of screen fire shutters in the Goyang Bus Terminal fire based on the fire investigation results. At that time, screen fire shutters in the 1st basement, which was under construction, did not work because the power was shut off. Four screen fire shutters in the 1st and 3rd floor did not work despite the power not being shut off. The following problems related to a screen fire shutter were found: shutting off the power to screen fire shutters for the fire compartment on each floor, even when the fire compartments were changed in each area; installing an integral type screen fire shutter without any regulations, installing a two-stage screen fire shutter in a place not related to obstacles during evacuation; stopping the function of the screen fire shutters for a fire compartment on each floor after a combustible sandwich panel was comparted; installing a screen fire shutter over 10 meters in width, in which its performance was not verified; and no safety control standards for reinstalling or maintaining a screen fire shutter.

A Study on Trace Metal Levels in Hair (모발중 미량 금속 함량에 관한 조사 연구)

  • Son, Busoon;Hong, Eunju;Kim, Yoonshin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.233-244
    • /
    • 1997
  • In order to investigate the concentration of trace metals in human hairs from residents living in urban area and rural area, the 120 hair samples of adults were taken from urban areas(industrial area, bus terminal, downtown area) and rural area(Kasan-ri, Yeoju-up, Yeoju-goon) during July - September 1995. Mean concentrations of trace metals including lead and cadmium in human hair were compared by region, sex, presence of smoker, type of water, period of residence. The results were as follows; 1. The average concentrations of lead and cadmium in hairs of urban area are $0.92{\mu}g/g$ ($1.01{\mu}g/g$ industrial area, $1.01{\mu}g/g$ bus terminal, $0.74{\mu}g/g$ downtown area), $0.38{\mu}g/g$ ($0.54{\mu}g/g$ industrial area, $0.49{\mu}g/g$ bus terminal, $0.12{\mu}g/g$ downtown area). The mean concentrations of lead and cadmium in urban area are higher than the corresponding levels in the rural area. 2. Lead concentration for male in the urban and rural area is 0.94 and $0.62{\mu}g/g$, 0.90 and $0.60{\mu}g/g$ for female. But, It does not have any statistical significance. Cadmium concentration for male in the urban and rural area is 0.38 and $0.12{\mu}g/g$, 0.38 and $0.11{\mu}g/g$ for female. But It does not have any statistical significance. 3. Mean concentrations of lead and cadmium in smokers shows higher than non-smokers. It showed that the longer period of residence in urban area, the higher concentrations of three metals.

  • PDF

Influence Factors on User Satisfaction of Commercial Areas in Downtown -focused on commercial areas near Cheonan railway station and central bus terminal- (도심 상업지역 이용자 만족도에 미치는 영향요소 분석 -천안역과 종합버스터미널 주변 상업지역을 중심으로-)

  • Jeong, Jae-Jin;Kim, Sung-Gil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.5274-5280
    • /
    • 2013
  • The aim of this study is to analyze the general satisfaction of the commercial areas near Cheonan central bus terminal and the rail-station and to extract various environmental factors of the city center which give effect to the user satisfaction of commercial area. As the result of the analyses, the environmental factors of the city center make a difference between the commercial areas of Cheonan central bus terminal and of the station in the aspects of user satisfaction. The user satisfaction of the commercial areas is appeared highest in 'comfort of walking environments' and 'convenience of commerce business transaction' which were environmental factors of the city center. For reactivation of the commercial area near Cheonan rail-station are needed improvement of walking environments and relocation of facilities as complex mall and bank etc.

Data Visualization Design of Bus Information Terminal using Smart Client Platform (Smart Client 기반 BIT 시각화 설계)

  • Kim, Joohwan;Nam, Doohee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.4
    • /
    • pp.55-60
    • /
    • 2013
  • Smart client is a term describing an application environment which delivers applications over a web HTTP connection and does not require installation and/or updates. The term "Smart Client" is meant to refer to simultaneously capturing the benefits of a "thin client" (zero-install, auto-update) and a "fat client" (high performance, high productivity). A "Smart Client" application can be created in several very different technologies. Over the past few years, ITS has started to move towards smart clients, also called rich clients. The trend is a move from traditional client/server architecture to a Web-based model. More similar to a fat client vs. a thin client, smart clients are Internet-connected devices that allows a user's local applications to interact with server-based applications through the use of Web services. Smart Client applications in BIT bridge the gap between web applications and desktop applications. They provide the benefits of a web applicationwhile still providing the snappy look and feel inherent to desktop applications.

Analysis on Pedestrian Crossing Illegal Behavior on Exclusive Median Bus Corridor: A Cace Study of Express Bus Terminal Station (중앙버스전용차로 횡단보도 보행 위반행태 분석: 고속버스터미널역 사례 분석)

  • Lee, Dong-Il;Kim, Jin Tae;Kim, Jun-Yong;Bae, Hyun-Sik
    • Journal of Korean Society of Transportation
    • /
    • v.33 no.2
    • /
    • pp.136-144
    • /
    • 2015
  • It has reported that a median bus-stop island on an exclusive median bus corridor has shortened a unit crossing distance, encouraged a pedestrian's illegal jay walking, and thus increased the number of accidents in the area. Therefore, this study plans to analyze the various crossing patterns of pedestrians at exclusive median bus corridors. This study analyzes 30,184 pedestrian crossing data which are collected from the median bus-stops, 'Express Bus Terminal,' and reveals that the rate of spatial jaywalking was 37.8%. This rate is 11.1 times higher than the rate of traffic signal violation. Therefore, this study suggests that more research needs to be done to provide a traffic safety facilities for protecting spatial crossing pedestrians and preventing jaywalking and traffic signal violation.

Design and Implementation of Smart Bus Information System(SBIS) based on Smartphone Server Network (스마트폰 서버 네트워크 기반의 스마트 버스운행정보시스템)

  • Moon, Jae Young;Im, Kwang Hyuk
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.458-465
    • /
    • 2013
  • The purpose of this research is possible to reduce cost of management and maintenance to realization of smartphone and using data server network technology instead of GPS. Former wireless bus information system was focused on supply side management structure and national spread thus it needs to establish GPS terminal, Windows CE, Window XP embedded and LCD panels which provide only one way communication of information of public traffic information. Therefore, former system management and maintenance cost are very expansive. This research is not use GPS terminal and other hardware equipment but design and realization using smartphone and data network server. This system also provides low cost of management and maintenance. It is not only service downtown area but also out of town and small and medium-sized cities. This system functionally gets a satisfying result user convenience and satisfaction using function of set-up route map, real-time display, and running statically analysis.